北京大学学报(医学版) ›› 2018, Vol. 50 ›› Issue (1): 58-62. doi: 10.3969/j.issn.1671-167X.2018.01.010

• 论著 • 上一篇    下一篇

凝固时间对生物活性盖髓材料表面粘接强度的影响

董颖韬1,田福聪2△,贾斌1,祖斌1,王晓燕2   

  1. (1. 北京市崇文口腔医院特需科, 北京100062; 2. 北京大学口腔医学院·口腔医院,牙体牙髓科口腔数字化医疗技术和材料国家工程实验室口腔数字医学北京重点实验室, 北京100081)
  • 出版日期:2018-02-18 发布日期:2018-02-18
  • 通讯作者: 田福聪 E-mail:tfc8132@sina.com
  • 基金资助:
    北京大学口腔医院临床新技术新疗法项目(PKUSSNCT-14B15)资助

Influence of setting time on bond strength of different bioactive pulp capping mate-rials with dental adhesive

DONG Ying-tao1, TIAN Fu-cong2△, JIA Bin1, ZU Bin1, WANG Xiao-yan2   

  1. (1. Department of VIP Dental Service, Peking Chongwen Hospital of Stomatology, Beijing 100062, China; 2. Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China)
  • Online:2018-02-18 Published:2018-02-18
  • Contact: TIAN Fu-cong E-mail:tfc8132@sina.com
  • Supported by:
    Supported by Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology (PKUSSNCT-14B15)

摘要: 目的:观察不同生物活性盖髓材料在初始凝固及完全凝固后,与自酸蚀或酸蚀冲洗粘接系统之间的粘接强度。方法:制备三氧化矿物凝聚体(mineral trioxide aggregate,MTA)、iRoot BP Plus(BP)及iRoot FS(FS)试件各60个,分成三组,分别在材料初始凝固时间(MTA 4 h,BP 2 h,FS 20 min)、24 h、7 d三个时间点对材料表面进行粘接处理,将各材料组随机分为两组,分别用通用粘接剂(Single Bond Universal,SBU)自酸蚀模式或酸蚀冲洗模式进行粘接(n=10),限制粘接面积为直径3 mm圆形,上方制作复合树脂柱后测试其剪切强度并记录断裂模式,计算剪切粘接强度值后采用SPSS 19.0软件中的方差分析方法进行统计分析。采用扫描电镜观察凝固后材料表面形貌及经过不同酸蚀处理后的表面微观形态。结果:三种材料的自酸蚀和酸蚀冲洗粘接强度在初始凝固、7 d时的粘接强度比较差异均无统计学意义(P<0.05);凝固24 h后,MTA的自酸蚀和酸蚀冲洗粘接强度均显著高于FS与BP(P<0.05);同种材料完全凝固后粘接强度均显著高于初始凝固组;各组试样断裂均为盖髓材料内聚破坏。扫描电镜下可见三种材料表面特征性晶体结构,MTA表面晶体较另外两者大;经酸蚀处理后,三种材料表面晶体特征均有不同程度破坏。结论:本研究范围内,FS在较短初始凝固时间即可获得一定的粘接强度,与初始凝固时MTA和BP粘接强度无明显差异。临床条件下可以在盖髓材料初始凝固(20 min)后进行树脂直接修复,以提高临床效果与效率。

关键词: 盖髓术, 生物活性材料, 剪切强度, 粘接剂, 凝固时间

Abstract: Objective: To investigate influence of setting time on bond strength of different bioactive pulp capping materials with self-etch or etch-and-rinse adhesive. Methods: Sixty specimens were prepared for each of the three tested capping materials, namely mineral trioxide aggregate (MTA), iRoot BP Plus (BP) and iRoot FS (FS). Specimens of each material were divided into three groups and bonded at three setting time points of the materials respectively: initial setting time (4 h for MTA, 2 h for BP and 20 min for FS), 24 h after application and 7 d after application. The specimen surfaces of each group were treated with self-etch mode or etch-and-rinse mode of one universal adhesive (Single Bond Universal, SBU) (n=10). The bonding area was restricted to a round area with 3 mm diameter, on which composite cylinders were build up with flowable composite and light cured completely. The shear bond strength was tested immediately with a shear strength tester and fracture mode was observed under stereo microscope and recorded. The mean shear bond strength for each group was analyzed with SPSS 19.0 software ANOVA method. The surface morphology of each material was observed after setting and acid treatment under scanning electron microscope. Results: There was no significant difference among the three tested materials at either initial setting point or 7 d after application (P<0.05). The bond strength of MTA was significantly higher than those of BP and FS 24 h after application in both bonding modes (P<0.05). For all the three tested materials, shear bond strength was significantly higher for complete setting group than for initial setting group of the same material (P<0.05). Under scanning electron microscope, the characteristic crystal patterns could be observed on the three bioactive materials surfaces after complete setting, the size of which was bigger for MTA than for BP and FS. These features were lost to some extent after self-etch primer application or phosphoric acid etching. Conclusion: Based on the present results, adequate bond strength can be obtained for FS at initial setting time, which is comparable with BP and MTA. This implies that clinically composite restoration can be placed over bioactive direct capping materials after shortened initial setting process in one visit.

Key words: Dental pulp capping, Bioactive materials, Shear strength, Adhesives, Setting time

中图分类号: 

  • R783.1
[1] 宫玮玉,刘绍清,董艳梅,高学军,陈晓峰. 纳米生物活性玻璃促进兔颅骨临界骨缺损修复[J]. 北京大学学报(医学版), 2018, 50(1): 42-48.
[2] 唐琳,张一,李皓,刘玉华,周永胜,李博文,吴唯伊,王思雯. 不同浓度的碳二亚胺乙醇溶液处理对牙本质自酸蚀粘接剂粘接强度的影响[J]. 北京大学学报(医学版), 2017, 49(6): 1055-1059.
[3] 朱曚曚, 王国敏, 孙科, 李应龙, 潘洁. 低温等离子体用于牙齿外漂白后对牙釉质粘接强度的影响[J]. 北京大学学报(医学版), 2016, 48(1): 116-120.
[4] 张路, 袁重阳, 田福聪, 王晓燕, 高学军. 自酸蚀粘接剂系统对变形链球菌的抑制作用[J]. 北京大学学报(医学版), 2016, 48(1): 57-62.
[5] 张丽丽, 罗铮, 张一, 刘玉华. 两种自酸蚀核树脂/水门汀与冠部牙本质粘接强度的比较[J]. 北京大学学报(医学版), 2015, 47(2): 364-367.
[6] 白伟, 林红, 郑刚. 一步法粘接剂对金属、陶瓷材料粘接性能的研究[J]. 北京大学学报(医学版), 2014, 46(2): 336-338.
[7] 吕品, 姜婷. 热酸蚀处理对氧化锆表面剪切粘接强度的影响[J]. 北京大学学报(医学版), 2014, 46(2): 302-305.
[8] 田福聪, 王晓燕, 高学军. 温度循环对自酸蚀粘接剂与牙本质粘接耐久性的影响[J]. 北京大学学报(医学版), 2014, 46(2): 284-287.
[9] 田福聪,王晓燕,高学军. 不同粘接系统用于楔状缺损直接修复的临床观察[J]. 北京大学学报(医学版), 2014, 46(1): 58-61.
[10] 周丽晶, 胡白河. 酸蚀时间对牙颈部非龋性硬化牙本质粘接界面形态的影响[J]. 北京大学学报(医学版), 2006, 38(2): 204-206.
[11] 周丽晶, 谭建国, 胡白河, 冯海兰. 牙颈部非龋性硬化牙本质经全酸蚀牙本质粘接剂处理后的超微形态[J]. 北京大学学报(医学版), 2004, 36(3): 319-321.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 张三. 中文标题测试[J]. 北京大学学报(医学版), 2010, 42(1): 1 -10 .
[2] 赵磊, 王天龙 . 右心室舒张末期容量监测用于肝移植术中容量管理的临床研究[J]. 北京大学学报(医学版), 2009, 41(2): 188 -191 .
[3] 万有, , 韩济生, John E. Pintar. 孤啡肽基因敲除小鼠电针镇痛作用增强[J]. 北京大学学报(医学版), 2009, 41(3): 376 -379 .
[4] 张燕, 韩志慧, 钟延丰, 王盛兰, 李玲玲, 郑丹枫. 骨骼肌活组织检查病理诊断技术的改进及应用[J]. 北京大学学报(医学版), 2009, 41(4): 459 -462 .
[5] 林红, 王玉凤, 吴野平. 学校生活技能教育对小学三年级学生行为问题影响的对照研究[J]. 北京大学学报(医学版), 2007, 39(3): 319 -322 .
[6] 丰雷, 程嘉, 王玉凤. 注意缺陷多动障碍儿童的运动协调功能[J]. 北京大学学报(医学版), 2007, 39(3): 333 -336 .
[7] 李岳玲, 钱秋瑾, 王玉凤. 儿童注意缺陷多动障碍成人期预后及其预测因素[J]. 北京大学学报(医学版), 2007, 39(3): 337 -340 .
[8] . 书讯[J]. 北京大学学报(医学版), 2007, 39(3): 225 -328 .
[9] 牟向东, 王广发, 刁小莉, 阙呈立. 肺黏膜相关淋巴组织型边缘区B细胞淋巴瘤一例[J]. 北京大学学报(医学版), 2007, 39(4): 346 -350 .
[10] 韩金涛, 赵军, 栾景源, 张龙. 多发结核性腹主动脉瘤一例[J]. 北京大学学报(医学版), 2007, 39(4): 361 -364 .