Journal of Peking University(Health Sciences) ›› 2017, Vol. 49 ›› Issue (4): 704-708. doi: 10.3969/j.issn.1671-167X.2017.04.028

• Article • Previous Articles     Next Articles

Precision of three-dimensional printed brackets#br#

ZHANG Da, WANG Lin-chuan, ZHOU Yan-heng, LIU Xiao-mo, LI Jing△   

  1. (Department of Orthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China)
  • Online:2017-08-18 Published:2017-08-18
  • Contact: LI Jing E-mail: lijing1101@hotmail.com
  • Supported by:
    Supported by Youth Fund of Peking University Hospital of Stomatology

Abstract: Objective:This study was based on digital orthodontic diagnosis work flow for indirect bonding transfer tray model design and three-dimensional (3D) printing, and the aim of this paper was to inspect the dimensional accuracyof 3D printed brackets, which is the foundation of the follow up work and hoped that will illuminate the clinical application of the digital orthodontics work flow. Methods: The samples which consisted of 14 cases of patients with malocclusion from Department of Orthodontics Peking University were selected, including 8 cases with tooth extraction and 6 cases without tooth extraction.All the 14 patients were taken intra-oral scan (Trios 3Shape,Denmark)and cone-beam computed tomography (CBCT, NewTom 3G volumetric scanner, Aperio Service,Italy)shooting after periodontal treatment. STL data and DICOM data were obtained from intraoral scans and CBCT images.Data segmentation, registration, fusion, automatic tooth arrangement, virtual positioning of orthodontic appliance and conversion the coordinates of malocclusion model were all done with self-programming software. The data of 3D printing model with brackets on it were output finally and printed out with EDEN260V (Objet Geometries, Israel) to make indirect bonding transfer tray. Digital vernier caliper was used to measure the length and width of upper and lower left brackets and buccal tubes on those 3D models after removal of surrounding supporting material by ultrasonic vibration and water-spray. Intra-examiner reliability was assessed by using intra-class correlation coefficients (ICC), and one-sample T test was used to compare the measurements with the standard dimensional data of the brackets. Results: There were significant differences which range in 0.04-0.17 mm between the 13 items out of the 19 measurement items. Except for the length of the lower left premolars’brackets, mean values of the other items were greater than the test value.Conclusion: Although the measurement results in the width of brackets and the width and length of the buccal tubes obtained experimentally were slightly larger than the test value,this may not reduce the accuracy of indirect bonding procedure in clinic necessarily. Whether the differences which range in 0.04-0.17 mm would actually affect the retention and positioning of brackets needs to be confirmed by further studies.

Key words: 3D printing, Bracket, Orthodontics, Indirect bonding

CLC Number: 

  • R783.5
[1] SUN Yu-chun,GUO Yu-qing,CHEN Hu,DENG Ke-hui,LI Wei-wei. Independent innovation research, development and transformation of precise bionic repair technology for oral prosthesis [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 7-12.
[2] Gao-nan WANG,Jian JIAO,Yan-heng ZHOU,Jie SHI. Effect of orthodontic tooth movement on keratinized gingival width [J]. Journal of Peking University(Health Sciences), 2019, 51(5): 931-936.
[3] DAI Fan-fan, LIU Yi, XU Tian-min, CHEN Gui. Exploring a new method for superimposition of pre-treatment and post-treatment mandibular digital dental casts in adults [J]. Journal of Peking University(Health Sciences), 2018, 50(2): 271-278.
[4] . Stress change of periodontal ligament of the anterior teeth at the stage of space closure in lingual appliances: a 3-dimensional finite element analysis [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 141-147.
[5] SHEN Xiao, SHI Jie, XU Li, JIAO Jian, LU Rui-fang, MENG Huan-xin. Clinical evaluation of periodontal-orthodontic treatment in patients with aggressive periodontitis and malocclusion [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 60-066.
[6] WEN Fu-jia,CHEN Gui,LIU Yi. Morphological analysis of roots and alveolar bone changes after upper anterior #br# retraction with maximum anchorage based on cone-beam computed tomography [J]. Journal of Peking University(Health Sciences), 2016, 48(4): 702-708.
[7] HUANG Jun-qiang, LIU Shi-yao, JIANG Jiu-hui. Therapeutic evaluation of the correction of the severe bi-maxillary protrusion cases by Tweed-Merrifield technique [J]. Journal of Peking University(Health Sciences), 2016, 48(3): 555-561.
[8] SONG Guang-Ying, JIANG Ruo-Ping, ZHANG Xiao-Yun, LIU Si-Qi, YU Xiao-Nan, CHEN Qing, WENG Xuan-Rong, WU Wei-Zi, SU Hong, REN Chong, DAN Ru-Kai, GENG Zhi, XU Tian-Min, JIAN Li-Zhong-Guo-Zheng-Ji-Liao-Xiao-Ping-Jia-Biao-Zhun-Ke-Ti-Zu. Validation of subjective and objective evaluation methods for orthodontic treatment outcome [J]. Journal of Peking University(Health Sciences), 2015, 47(1): 90-97.
[9] PAN Yi-Chun, ZHAO Jian-Hui. Clinical outcome evaluation of midpalatal mini-implant anchorage system in orthodontic treatment [J]. Journal of Peking University(Health Sciences), 2014, 46(6): 969-974.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] Author. English Title Test[J]. Journal of Peking University(Health Sciences), 2010, 42(1): 1 -10 .
[2] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 188 -191 .
[3] . [J]. Journal of Peking University(Health Sciences), 2009, 41(3): 376 -379 .
[4] . [J]. Journal of Peking University(Health Sciences), 2009, 41(4): 459 -462 .
[5] . [J]. Journal of Peking University(Health Sciences), 2010, 42(1): 82 -84 .
[6] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 319 -322 .
[7] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 333 -336 .
[8] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 337 -340 .
[9] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 225 -328 .
[10] . [J]. Journal of Peking University(Health Sciences), 2007, 39(4): 346 -350 .