表1 模板法确定三维下颌骨标志点的定点误差
|
Table 1 Distance error of 3D mandible landmarks determined by template-method
|
|
| Number | Name of landmarks | Abbreviations | Distance error/mm, $\bar x \pm s$ | | 1 | Condylion (right) | CoR | 1.94±0.60 | | 2 | Condylion (left) | CoL | 2.24±0.97 | | 3 | Condyle lateral point (right) | CLPR | 0.77±0.50 | | 4 | Condyle lateral point (left) | CLPL | 0.96±0.38 | | 5 | Condyle medial point (right) | CMPR | 1.43±0.53 | | 6 | Condyle medial point (left) | CMPL | 1.37±0.44 | | 7 | Coronoid process (right) | CPR | 1.01±0.44 | | 8 | Coronoid process (left) | CPL | 0.56±0.14 | | 9 | Lowest point of the sigmoid notch (right) | LPSNR | 1.00±0.60 | | 10 | Lowest point of the sigmoid notch (left) | LPSNL | 0.75±0.37 | | 11 | Gonion (right) | GoR | 2.23±0.73 | | 12 | Gonion (left) | GoL | 1.82±1.17 | | 13 | Lowest anterior ramus (right) | LARR | 2.52±0.95 | | 14 | Lowest anterior ramus (left) | LARL | 2.57±1.10 | | 15 | Pogonion | Pog | 0.83±0.36 | | 16 | Menton | Me | 1.04±0.39 | | 17 | Gnathion | Gn | 0.84±0.32 | | 18 | Lower incisor | LI | 0.72±0.39 | | 19 | Supramental | B | 2.33±1.06 |
|
|
|