Journal of Peking University(Health Sciences) ›› 2015, Vol. 47 ›› Issue (2): 330-335. doi: 10.3969/j.issn.1671-167X.2015.02.028

• Articles • Previous Articles     Next Articles

Dentin barrier cytotoxicity test with three-dimensional cell cultures

JIANG Ruo-dan1,LIN Hong1△,ZHENG Gang1,YUAN Shen-po1,DU Qiao2,ZHANG Yan1   

  1. (1.Dental Medical Devices Testing Center, Dental Materials Laboratory, National Engineering Laboratory for Digital and Material Technology of Stomatology, Peking University School and Hospital of Stomatology, Beijing 100081, China; 2.Department of Stomatology, Beijing Hospital of Chinese Traditional and Western Medicine, Beijing 100039, China)
  • Online:2015-04-18 Published:2015-04-18

Abstract: Objective: To evaluate the cytotoxicity of four dentin filling materials and two dentin adhesives with a dentin barrier test and to compare the results with those in a conventional filter diffusion test in order to investigate the advantages of the dentin barrier test. Methods: Eugenol cement, zinc phosphate cement, adhesive glass ionomer cement, composite resin and two self-etching adhesives (REMI BOND and Adper Easy One) were tested. In the dentin barrier test, L929 mouse fibroblasts were three-dimensional cultured in polystyrene meshes. The dentin disks were cut from the human third molars, near the pulp and in parallel with the occlusal surface, and their permeability within the measurement area was evaluated by a hydraulic permeability device. A mesh with the cells was placed in the “pulp cavity” of the chamber and one dentin disk was put on the cell mesh and its “pulp side” was in contact with the mesh. The test materials and controls were in contact with the “occlusal side” of the dentine disks for 24 h. The cell viability was obtained with MTT assay and the results were expressed as a percentage of control tissues. The Mann-Whitney U test was used to make the statistical analyses. In the filter diffusion test, after a 24 h contact between the test materials and the filters with monolayer cells, the filters were dyed and the grades of cytotoxicity were decided. Results: A mean permeability of the dentin disks near the pulp was 0.293 μL/(min·cm2·cmH2O)(1 cmH2O=0.098 kPa); In the dentin barrier test, Eugenol cement, REMI BOND and Adper Easy One respectively reduced the cell survival rates to 82%, 63% and 54%. Other materials showed no or very low toxic reactions; In the filter diffusion test, the lightcuring composite resin was moderately cytotoxic, the dental adhesive glass ionomer cement was mildly cytotoxic and the others were severely cytotoxic; All the six materials in the dentin barrier test had lower cytotoxicity than in the filter diffusion test. Conclusion: The cytotoxicity of the test materials using the dentin barrier test with threedimensional cell cultures is lower than that in the filter diffusion test, which has good correlation with the clinical situation.

Key words: Cytotoxicity tests, Dentin permeability, Cell survival, Dentin-bonding agents, Cell culture technique

CLC Number: 

  • R783.1
[1] FU Zhao-ran,TIAN Fu-cong,ZHANG Lu,HAN Bing,WANG Xiao-yan. Curing mode of universal adhesives affects the bond strength of resin cements to dentin [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 101-104.
[2] ZHANG Lu, YUAN Chong-yang, TIAN Fu-cong, WANG Xiao-yan, GAO Xue-jun. Antibacterial effect of self-etching adhesive systems on Streptococcus mutans [J]. Journal of Peking University(Health Sciences), 2016, 48(1): 57-62.
[3] TIAN Fu-Cong, WANG Xiao-Yan, Gao-Xue-Jun. Influence of thermalcycling on bonding durability of selfetch adhesives with dentin [J]. Journal of Peking University(Health Sciences), 2014, 46(2): 284-287.
[4] ZHANG Feng-Qiu, MENG Huan-Xin, HAN Jie, DING Qian. Isolation, culture and ultrastructure analysis of mesenchymal stem cells from human periodontal ligament [J]. Journal of Peking University(Health Sciences), 2014, 46(2): 274-277.
[5] TIAN Fu-cong, WANG Xiao-yan, GAO Xue-jun. Clinical evaluation of a two-step etch-and-rinse adhesive and a one-step self-etch adhesive in non-carious cervical lesion [J]. Journal of Peking University(Health Sciences), 2014, 46(1): 58-61.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. Journal of Peking University(Health Sciences), 2009, 41(4): 456 -458 .
[2] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 125 -128 .
[3] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 135 -140 .
[4] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 217 -220 .
[5] . [J]. Journal of Peking University(Health Sciences), 2009, 41(1): 52 -55 .
[6] . [J]. Journal of Peking University(Health Sciences), 2009, 41(1): 109 -111 .
[7] . [J]. Journal of Peking University(Health Sciences), 2009, 41(3): 297 -301 .
[8] . [J]. Journal of Peking University(Health Sciences), 2009, 41(5): 505 -515 .
[9] . [J]. Journal of Peking University(Health Sciences), 2009, 41(5): 599 -601 .
[10] . [J]. Journal of Peking University(Health Sciences), 2009, 41(5): 516 -520 .