Determination of UV-327 and UV-328 in mouse plasma by high performance liquid chromatography

  • Mei-qing ZHU ,
  • Rong CUI
Expand
  • Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing 100191, China

Received date: 2020-01-09

  Online published: 2020-06-30

Abstract

Objective: To establish a high performance liquid chromatography (HPLC) method for the determination of ultraviolet (UV) absorbers UV-327 and UV-328 in mouse plasma.Methods: N-hexane-acetone (volume ratio 1 ∶1) was added to a mouse plasma sample as the extraction solvent for vortex extraction, and the supernatant was dried at 50 ℃ with nitrogen. Thereafter the residue was redissolved with methanol, centrifuged and filtered. The separation was performed on a Waters Symmetry?C18 column (250 mm×4.6 mm, 5 μm), and the concentrations of UV-327 and UV-328 in the mouse plasma were determined by HPLC with an UV detector. The elution was isocratic at a flow rate of 1.0 mL/min with a mobile phase composed of 100% methanol, and the UV detection wavelength was 340 nm. The retention time was used for qualitative analysis, and the internal standard method was used for quantitative analysis using UV-320 as the internal standard. Results: The calibration curves of UV-327 and UV-328 were linear with correlation coefficients of 0.999 7 over the concentration range of 0.05 to 10.0 mg/L. The limit of detection was 0.01 mg/L, and the limit of quantitation was 0.03 mg/L. The average recoveries at low, medium and high three concentrations (0.50, 1.00, 2.00 mg/L) in the mouse plasma were 91.7%-101.0% for UV-327, and 97.5%-103.9% for UV-328. The intra-day precisions (n=6) of UV-327 were 2.9%-6.6%, and 2.7%-7.4% for UV-328. The inter-day precisions (n=3) of UV-327 were 6.0%-9.3%, and 6.6%-8.6% for UV-328. The extraction recoveries of UV-327 were 98.8%-103.8%, and 99.8%-100.9% for UV-328. The measured relative deviations of UV-327 in the mouse plasma samples placed at room temperature for 6 hours and -40 ℃ for 15 days were 0.9%-3.5% and 7.4%-15.0%, and the measured relative deviations of UV-328 were 2.0%-4.3% and 2.1%-13.8%, respectively. The mouse plasma samples could be stored at room temperature for 6 hours at least and -40 ℃ for 15 days at three spiked concentration levels.Conclusion: The method was simple and fast with high accuracy, precision and sensitivity, and could be applied to the determination of UV-327 and UV-328 in mouse plasma.

Cite this article

Mei-qing ZHU , Rong CUI . Determination of UV-327 and UV-328 in mouse plasma by high performance liquid chromatography[J]. Journal of Peking University(Health Sciences), 2020 , 52(3) : 591 -596 . DOI: 10.19723/j.issn.1671-167X.2020.03.030

References

[1] 王晶, 张子豪, 刘莹峰, 等. 3类高关注紫外线吸收剂的前处理与检测技术研究进展[J]. 分析测试学报, 2016,35(11):1505-1512.
[2] 赵海浪, 谭玉静, 韩宁, 等. GC-MS法快速测定纺织品中4种苯并三唑类紫外线吸收剂[J]. 印染, 2018,44(4):43-47.
[3] Nakata H, Murata S, Filatreau J. Occurrence and concentrations of benzotriazole UV stabilizers in marine organisms and sediments from the Ariake Sea, Japan[J]. Environ Sci Technol, 2009,43(18):6920-6926.
[4] Langford KH, Reid MJ, Fjeld E, et al. Environmental occurrence and risk of organic UV filters and stabilizers in multiple matrices in Norway[J]. Environ Int, 2015,80:1-7.
[5] Hirata-Koizumi M, Watari N, Mukai D, et al. A 28-day repeated dose toxicity study of ultraviolet absorber 2-(2'-hydroxy-3',5'-di-tert-butylphenyl) benzotriazole in rats[J]. Drug Chem Toxicol, 2007,30(4):327-341.
[6] Hirata-Koizumi M, Ogata H, Imai T, et al. A 52-week repeated dose toxicity study of ultraviolet absorber 2-(2'-hydroxy-3',5'-di-tert-butylphenyl)benzotriazole in rats[J]. Drug Chem Toxicol, 2008,31(1):81-96.
[7] Hirata-Koizumi M, Matsuyama T, Imai T, et al. Gender-related difference in the toxicity of ultraviolet absorber 2-(3',5'-di-tert-butyl-2'-hydroxyphenyl)-5-chlorobenzotriazole in rats[J]. Drug Chem Toxicol, 2008,31(3):383-398.
[8] Muir DC, Howard PH. Are there other persistent organic pollutants? A challenge for environmental chemists[J]. Environ Sci Technol, 2006,40(23):7157-7166.
[9] 中国国家标准化管理委员会. GB9685—2008 食品容器、包装材料用添加剂使用卫生标准[S]. 北京: 中华人民共和国卫生部、中国国家标准化管理委员会, 2008.
[10] Nakata H, Shinohara R, Murata S, et al. Detection of benzo-triazole UV stabilizers in the blubber of marine mammals by gas chromatography-high resolution mass spectrometry (GC-HRMS)[J]. J Environ Monit, 2010,12(11):2088-2092.
[11] Lee S, Kim S, Park J, et al. Synthetic musk compounds and benzotriazole ultraviolet stabilizers in breast milk: Occurrence, time-course variation and infant health risk[J]. Environ Res, 2015,140:466-473.
[12] Kim JW, Isobe T, Ramaswamy BR, et al. Contamination and bioaccumulation of benzotriazole ultraviolet stabilizers in fish from Manila Bay, the Philippines using an ultra-fast liquid chromatography-tandem mass spectrometry[J]. Chemosphere, 2011,85(5):751-758.
[13] Lu Z, Peart TE, Cook CJ, et al. Simultaneous determination of substituted diphenylamine antioxidants and benzotriazole ultra violet stabilizers in blood plasma and fish homogenates by ultra high performance liquid chromatography-electrospray tandem mass spectrometry[J]. J Chromatogr A, 2016,1461:51-58.
[14] Lu Z, De Silva AO, Zhou W, et al. Substituted diphenylamine antioxidants and benzotriazole UV stabilizers in blood plasma of fish, turtles, birds and dolphins from North America[J]. Sci Total Environ, 2019,647:182-190.
[15] Peng X, Jin J, Wang C, et al. Multi-target determination of organic ultraviolet absorbents in organism tissues by ultrasonic assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry[J]. J Chromatogr A, 2015,1384:97-106.
[16] 李雯镜, 李志彤, 梁雪芳. 苯并三唑类紫外稳定剂在环境中的检测、分布及其毒性效应[J]. 生态毒理学报, 2018,13(1):89-105.
[17] 王成云, 刘彩明, 刘北卓, 等. 高效液相色谱法测定人造革中苯并三唑类紫外线吸收剂的含量[J]. 聚氯乙烯, 2016,44(7):30-34.
Outlines

/