Application of biocopy function of temporary crown occlusal morphology in patients with severe attrition

  • Zheng LI ,
  • Yu-shu LIU ,
  • Shi-min WANG ,
  • Rui ZHANG ,
  • Lu JIA ,
  • Hong-qiang YE ,
  • Wen-jie HU ,
  • Wen-yan ZHAO ,
  • Yun-song LIU ,
  • Yong-sheng ZHOU
Expand
  • 1. Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
    2. 2nd Dental Center, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
    3. Digital Laboratory, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
    4. Department of Periodontics, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
    5. Department of Implantation, Yinchuan Stomatology Hospital, Yinchuan 75002, China

Received date: 2020-10-09

  Online published: 2021-02-07

Supported by

New Clinical Technology of Peking University of Stomatology(PKUSSNCT-19G01);Grant of the Key Research and Development Program of Ningxia Hui Autonomous Region(2018BEG02012)

Abstract

Objective: To explore the preliminary application of “biocopy function” in digital technology of temporary crown in severe tooth attrition, so as to reduce the difficulty of final restoration adjustment in severe tooth wear cases, and save clinical time.Methods: Twelve patients aged between 40 and 65 years with severe tooth attrition were recruited in this study. The experimental group (6 cases, 3 females and 3 males) used the method of digital copy of temporary restoration shape when making the final restoration, and the control group (6 cases, 3 females and 3 males) used the traditional method to make the final restoration. The mean time of central occlusal adjustment and protrusive and lateral occlusal adjustment of each crown, the number of follow-up visits of the patients were recorded and statistically analyzed. The occlusal comfort of the first and the third months after wearing the prosthesis was evaluated by the patients, and the difference of the occlusal comfort of the final prosthesis made by the two methods was compared (the full score was 10 points). The occlusal adjustment time and occlusal comfort score were used as measurement data. Single sample t test was used. The number of follow-up visits was count data. Rank sum test was used for non-normal continuous variables.Results: The mean occlusal time of each crown adjustment in the experimental group was significantly lower than that in the control group (P<0.01), and the median number of follow-up visits in the experimental group was lower than that in the control group (P<0.01). The average occlusal comfort score of the experimental group was higher than that of the control group at the first time (P<0.01). After three months of crown wearing, the median occlusal comfort score of the experimental group was higher than that of the control group (P<0.05).Conclusion: In the case of severe tooth attrition, it is feasible to use the “biocopy function” in the design software to design the final prosthesis, which is conducive to reduce the difficulty of adjustment and achieve predictable functional and aesthetic effects, which is of great significance to save clinical time and improve the accuracy of restoration.

Cite this article

Zheng LI , Yu-shu LIU , Shi-min WANG , Rui ZHANG , Lu JIA , Hong-qiang YE , Wen-jie HU , Wen-yan ZHAO , Yun-song LIU , Yong-sheng ZHOU . Application of biocopy function of temporary crown occlusal morphology in patients with severe attrition[J]. Journal of Peking University(Health Sciences), 2021 , 53(1) : 62 -68 . DOI: 10.19723/j.issn.1671-167X.2021.01.010

References

[1] 李波, 易新竹. 牙列重度磨耗的研究现状[J]. 日本医学介绍, 2001,22(7):327-329.
[2] Calamita M, Coachman C, Sesma N, et al. Occlusal vertical dimension: treatment planning decisions and management considerations[J]. Int J Esthet Dent, 2019,14(2):166-181.
[3] Takeuchi Y, Koizumi H, Furuchi M, et al. Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses[J]. J Oral Sci, 2018,60(1):1-7.
[4] 李峥, 柳玉树, 叶红强, 等. 数字化修复结合牙周手术解决复杂前牙美学缺陷[J]. 北京大学学报(医学版), 2017,49(1):71-75.
[5] 刘云松, 叶红强, 谷明, 等. 患者参与的数字化设计在前牙美学修复中的应用[J]. 北京大学学报(医学版), 2014,46(1):90-94.
[6] 王芳萍, 温玉茹, 谭建国, 等. 全口牙列重度磨耗患者的功能和美学重建[J]. 中华口腔医学杂志, 2019,54(6):406-409.
[7] Spear FM. Interdisciplinary management of worn anterior teeth: facially generated treatment planning[J]. Dent Today, 2016,35(5):104-107.
[8] 王时敏, 李峥, 王冠博, 等. 全程数字化夜磨牙保护牙合垫的制作和初步应用[J]. 北京大学学报(医学版), 2019,51(01):111-116.
[9] 熊耀阳, 张松梅, 花葳蕾, 等. 数字化方法复制诊断饰面在重度氟斑牙全冠修复中的应用[J]. 中华口腔医学杂志, 2018,53(11):777-779.
[10] 吴冰, 吴国锋. 口腔修复CAD/CAM系统中的虚拟牙合架[J]. 实用口腔医学杂志, 2016,32(2):293-297.
[11] Wetselaar P, Lobbezoo F. The tooth wear evaluation system: a modular clinical guideline for the diagnosis and management planning of worn dentitions[J]. J Oral Rehabil, 2016,43(1):69-80.
[12] Peutzfeldt A, Jaeggi T, Lussi A. Restorative therapy of erosive lesions[J]. Monogr Oral Sci, 2014,25:253-261.
[13] Ferrando-Cascales á, Astudillo-Rubio D, Pascual-Moscardó A, et al. A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: a minimally invasive approach[J]. J Prosthet Dent, 2020,123(4):537-547.
[14] Tiwari B, Ladha K, Lalit A, et al. Occlusal concepts in full mouth rehabilitation: an overview[J]. J Indian Prosthodont Soc, 2014,14(4):344-351.
[15] Vyas R, Suchitra SR, Gaikwad PT, et al. Assessment of fracture resistance capacity of different core materials with porcelain fused to metal crown: an in vitro study[J]. J Contemp Dent Pract, 2018,19(4):389-392.
[16] Sannino G, Germano F, Arcuri L, et al. Cerec CAD/CAM chairside system[J]. Oral Implantol (Rome), 2014,7(3):57-70.
[17] Hsu MR, Driscoll CF, Romberg E, et al. Accuracy of dynamic virtual articulation: trueness and precision[J]. J Prosthodont, 2019,28(4):436-443.
Outlines

/