Objective: To quantitatively evaluate the trueness of five chairside three-dimensional facial scanning techniques, and to provide reference for the application of oral clinical diagnosis and treatment. Methods: The three-dimensional facial data of the subjects were collected by the traditional professional three-dimensional facial scanner Face Scan, which was used as the reference data of this study. Four kinds of portable three-dimensional facial scanners (including Space Spider, LEO, EVA and DS-FScan) and iPhone Ⅹ mobile phone (Bellus3D facial scanning APP) were used to collect three-dimensional facial data from the subjects. In Geomagic Studio 2013 software, through data registration, deviation analysis and other functions, the overall three-dimensional deviation and facial partition three-dimensional deviation of the above five chairside three-dimensional facial scanning technologies were calculated, and their trueness performance evaluated. Scanning time was recorded during the scanning process, and the subject's comfort was scored by visual analogue scale(VAS). The scanning efficiency and patient acceptance of the five three-dimensional facial scanning techniques were evaluated. Results: DS-FScan had the smallest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.334 mm and 0.329 mm, respectively. The iPhone Ⅹ mobile phone had the largest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.483 mm and 0.497 mm, respectively. The detailed features of the three-dimensional facial data obtained by Space Spider were the best. The iPhone Ⅹ mobile phone had the highest scanning efficiency and the highest acceptance by the subject. The average scanning time of the iPhone Ⅹ mobile phone was 14 s, and the VAS score of the subjects' scanning comfort was 9 points. Conclusion: Among the five chairside three-dimensional face scanning technologies, the trueness of the scan data of the four portable devices had no significant difference, and they were all better than the iPhone Ⅹ mobile phone scan. The subject with the iPhone Ⅹ scanning technology had the best expe-rience.
Ao-nan WEN , Wei LIU , Da-wei LIU , Yu-jia ZHU , Ning XIAO , Yong WANG , Yi-jiao ZHAO . Preliminary evaluation of the trueness of 5 chairside 3D facial scanning techniques[J]. Journal of Peking University(Health Sciences), 2023 , 55(2) : 343 -350 . DOI: 10.19723/j.issn.1671-167X.2023.02.021
| 1 | Fink M , Hirschfelder U , Hirschinger V , et al. Assessment of facial soft-tissue profiles based on lateral photographs versus three-dimensional face scans[J]. J Orofac Orthop, 2017, 78 (1): 70- 76. |
| 2 | Topsakal O , Akbas MI , Smith BS , et al. Evaluating the agreement and reliability of a web-based facial analysis tool for rhinoplasty[J]. Int J Comput Assist Radiol Surg, 2021, 16 (8): 1381- 1391. |
| 3 | Anas IY , Bamgbose BO , Nuhu S . A comparison between 2D and 3D methods of quantifying facial morphology[J]. Heliyon, 2019, 5 (6): e1880. |
| 4 | Stebel A , Desmedt D , Bronkhorst E , et al. Rating nasolabial appearance on three-dimensional images in cleft lip and palate: A comparison with standard photographs[J]. Eur J Orthod, 2016, 38 (2): 197- 201. |
| 5 | Krneta B , Primo IJ , Zhurov A , et al. Three-dimensional evaluation of facial morphology in children aged 5-6 years with a class Ⅲ malocclusion[J]. Eur J Orthod, 2014, 36 (2): 133- 139. |
| 6 | Bockey S , Berssenbrügge P , Dirksen D , et al. Computer-aided design of facial prostheses by means of 3D-data acquisition and following symmetry analysis[J]. J Craniomaxillofac Surg, 2018, 46 (8): 1320- 1328. |
| 7 | Farook TH , Jamayet NB , Abdullah JY , et al. Designing 3D prosthetic templates for maxillofacial defect rehabilitation: A comparative analysis of different virtual workflows[J]. Comput Biol Med, 2020, 118, 103646. |
| 8 | Duppe K , Becker M , Schonmeyr B . Evaluation of facial anthropometry using three-dimensional photogrammetry and direct mea-suring techniques[J]. J Craniofac Surg, 2018, 29 (5): 1245- 1251. |
| 9 | van der Meer WJ , Dijkstra PU , Visser A , et al. Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner[J]. Br J Oral Maxillofac Surg, 2014, 52 (10): 922- 927. |
| 10 | Andrade LM , Rodrigues da Silva AMB , Magri LV , et al. Repeatability study of angular and linear measurements on facial morpho-logy analysis by means of stereophotogrammetry[J]. J Craniofac Surg, 2017, 28 (4): 1107- 1111. |
| 11 | Zhao Y , Xiong Y , Wang Y . Three-dimensional accuracy of facial scan for facial deformities in clinics: A new evaluation method for facial scanner accuracy[J]. PLoS One, 2017, 12 (1): e169402. |
| 12 | Gaber A, Faher MF, Waned MA. Automated grading of facial paralysis using the Kinect v2: A proof of concept study: International Conference on Virtual Rehabilitation (ICVR)[C]. Valencia, Spain: IEEE, 2015: 258-264. |
| 13 | Sidequersky FV , Verze L , Mapelli A , et al. Quantification of facial movements by optical instruments: Surface laser scanning and optoelectronic three-dimensional motion analyzer[J]. J Craniofac Surg, 2014, 25 (1): e65- e70. |
| 14 | Gaber A , Taher MF , Wahed MA . Quantifying facial paralysis using the Kinect v2[J]. Annu Int Conf IEEE Eng Med Biol Soc, 2015, 2015, 2497- 2501. |
| 15 | Knoops PG , Beaumont CA , Borghi A , et al. Comparison of three-dimensional scanner systems for craniomaxillofacial imaging[J]. J Plast Reconstr Aesthet Surg, 2017, 70 (4): 441- 449. |
| 16 | Modabber A , Peters F , Kniha K , et al. Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning[J]. J Craniomaxillofac Surg, 2016, 44 (10): 1719- 1724. |
| 17 | Ahn H , Chang Y , Kim K , et al. Measurement of three-dimensional perioral soft tissue changes in dentoalveolar protrusion patients after orthodontic treatment using a structured light scanner[J]. Angle Orthod, 2014, 84 (5): 795- 802. |
| 18 | Dindaro?lu F , Kutlu P , Duran GS , et al. Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry[J]. Angle Orthod, 2016, 86 (3): 487- 494. |
| 19 | 熊玉雪, 杨慧芳, 赵一姣, 等. 两种评价面部三维表面数据不对称度方法的比较[J]. 北京大学学报(医学版), 2015, 47 (2): 340- 343. |
| 20 | Zeng W , Chen G , Ju R , et al. The combined application of database and three-dimensional image registration technology in the restoration of total nose defect[J]. J Craniofac Surg, 2018, 29 (5): e484- e487. |
| 21 | 赵一姣, 熊玉雪, 杨慧芳, 等. 2种三维颜面部扫描仪测量精度的定量评价[J]. 实用口腔医学杂志, 2016, 32 (1): 37- 42. |
| 22 | Artopoulos A , Buytaert JA , Dirckx JJ , et al. Comparison of the accuracy of digital stereophotogrammetry and projection moiré profilometry for three-dimensional imaging of the face[J]. Int J Oral Maxillofac Surg, 2014, 43 (5): 654- 662. |
| 23 | Winder RJ , Darvann TA , McKnight W , et al. Technical validation of the Di3D stereophotogrammetry surface imaging system[J]. Br J Oral Maxillofac Surg, 2008, 46 (1): 33- 37. |
| 24 | Lo Russo L , Di Gioia C , Salamini A , et al. Integrating intraoral, perioral, and facial scans into the design of digital dentures[J]. J Prosthet Dent, 2020, 123 (4): 584- 588. |
| 25 | Swennen G , Pottel L , Haers PE . Custom-made 3D-printed face masks in case of pandemic crisis situations with a lack of commercially available FFP2/3 masks[J]. Int J Oral Maxillofac Surg, 2020, 49 (5): 673- 677. |
| 26 | Mai H , Lee D . The effect of perioral scan and artificial skin markers on the accuracy of virtual dentofacial integration: stereophotogrammetry versus smartphone three-dimensional face-scanning[J]. Int J Environ Res Public Health, 2021, 18 (1): 229. |
| 27 | Duran GS , Dindaroglu F , Kutlu P . Hard- and soft-tissue symmetry comparison in patients with Class Ⅲ malocclusion[J]. Am J Orthod Dentofacial Orthop, 2019, 155 (4): 509- 522. |
| 28 | 史雨林, 商洪涛, 田磊, 等. 骨性Ⅲ类错 畸形患者双颌手术前后面部软组织变化的三维研究[J]. 中国修复重建外科杂志, 2018, 32 (5): 612- 616. |
| 29 | 刘文静, 史雨林, 许方方, 等. 偏突颌畸形患者手术前后面部软组织的三维测量研究[J]. 现代生物医学进展, 2018, 18 (14): 2669- 2673. |
| 30 | Yamamoto S , Miyachi H , Fujii H , et al. Intuitive facial imaging method for evaluation of postoperative swelling: A combination of 3-dimensional computed tomography and laser surface scanning in orthognathic surgery[J]. J Oral Maxillofac Surg, 2016, 74 (12): 2501- 2506. |
| 31 | ?zsoy U , Uysal H , Hizay A , et al. Three-dimensional objective evaluation of facial palsy and follow-up of recovery with a handheld scanner[J]. J Plast Reconstr Aesthet Surg, 2021, 74 (12): 3404- 3414. |
| 32 | 王勇, 赵一姣, 司燕. 与三维测量有关的名词浅析[J]. 中华口腔正畸学杂志, 2009, 16 (2): 111- 113. |
| 33 | 陈俊锴, 孙玉春, 陈虎, 等. 口内三维扫描仪扫描精度的定量评价方法研究[J]. 中华口腔医学杂志, 2021, 56 (9): 920- 925. |
| 34 | 曹悦, 陈俊锴, 邓珂慧, 等. 三款口内三维扫描仪获取无牙颌红膏初印模精度的对比评价[J]. 北京大学学报(医学版), 2020, 52 (1): 129- 137. |
| 35 | Rudy HL , Wake N , Yee J , et al. Three-dimensional facial scanning at the fingertips of patients and surgeons: accuracy and precision testing of iphone Ⅹ three-dimensional scanner[J]. Plast Reconstr Surg, 2020, 146 (6): 1407- 1417. |
| 36 | 赵一姣, 熊玉雪, 杨慧芳, 等. 3种不同原理颜面部扫描仪测量精度的评价[J]. 北京大学学报(医学版), 2014, 46 (1): 76- 80. |
| 37 | Amornvit P , Sanohkan S . The accuracy of digital face scans obtained from 3d scanners: An in vitro study[J]. Int J Environ Res Public Health, 2019, 16 (24): 5061. |
| 38 | Petrides G , Clark JR , Low H , et al. Three-dimensional scanners for soft-tissue facial assessment in clinical practice[J]. J Plast Reconstr Aesthet Surg, 2021, 74 (3): 605- 614. |
/
| 〈 |
|
〉 |