Journal of Peking University (Health Sciences) ›› 2023, Vol. 55 ›› Issue (1): 144-148. doi: 10.19723/j.issn.1671-167X.2023.01.022

Previous Articles     Next Articles

3D-printed vertebral body in anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma

Hua ZHOU,Ren-ji WANG,Zhong-jun LIU,Xiao-guang LIU,Feng-liang WU,Lei DANG,Feng WEI*()   

  1. Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
  • Received:2022-03-25 Online:2023-02-18 Published:2023-01-31
  • Contact: Feng WEI E-mail:weifeng@bjmu.edu.cn
  • Supported by:
    the Key Clinical Projects of Peking University Third Hospital(BYSY2017001);Wu Jieping Medical Foundation Special Clinical Research Project(320.6750.2022-3-37)

RICH HTML

  

Abstract:

Objective: To investigate whether 3D-printed artificial vertebral body can reduce prosthesis subsidence rate for patients with cervical chordomas, through comparing the rates of prosthesis subsidence between 3D printing artificial vertebral body and titanium mesh for anterior spinal reconstruction after total spondylectomy. Methods: This was a retrospective analysis of patients who underwent surgical treatment for cervical chordoma at our hospital from March 2005 to September 2019. There were nine patients in the group of 3D artificial vertebral body (3D group), and 15 patients in the group of titanium mesh cage (Mesh group). The patients' characteristics and treatment data were extracted from the medical records, including age, gender, CT hounsfield unit of cervical vertebra and surgical information, such as the surgical segments, time and blood loss of surgery, frequency and degree of prosthesis subsidence after surgery. Radiographic observations of prosthesis subsidence during the follow-up, including X-rays, CT, and magnetic resonance imaging were also collected. SPSS 22.0 was used to analysis the data. Results: There was no significant difference between the two groups in gender, age, CT hounsfield unit, surgical segments, time of surgery, blood loss of posterior surgery and total blood loss. Blood loss of anterior surgery was 700 (300, 825) mL in 3D group and 1 500 (750, 2 800) mL in Mesh group (P < 0.05). The prosthesis subsidence during the follow-up, 3 months after surgery, there was significant difference between the two groups in mild prosthesis subsidence (P < 0.05). The vertebral height of the 3D group decreased less than 1 mm in eight cases (no prosthesis subsidence) and more than 1 mm in one case (mild prosthesis subsidence). The vertebral height of the Mesh group decreased less than 1 mm in five cases (no prosthesis subsidence), and more than 1 mm in eight cases (mild prosthesis subsidence). Two patients did not have X-rays in 3 months after surgery. There was a statistically significant difference between the two groups in the prosthesis subsidence rate at the end of 12 months (P < 0.01). The vertebral height of eight cases in the 3D group decreased less than 1 mm (no prosthesis subsidence) and one case more than 3 mm (severe prosthesis subsidence). Four of the 15 cases in the Mesh group decreased less than 1 mm (no prosthesis subsidence), two cases more than 1 mm (mild prosthesis subsidence), and nine cases more than 3 mm (severe prosthesis subsidence). There was a statistically significant difference between the two groups in the prosthesis subsidence rate at the end of 24 months (P < 0.01). The vertebral height of seven cases in the 3D group decreased less than 1 mm (no prosthesis subsidence), one case more than 3 mm (severe prosthesis subsidence), and one case died with tumor. One case in the Mesh group decreased less than 1 mm (no prosthesis subsidence), one case more than 1 mm (mild prosthesis subsidence), 11 case more than 3 mm (severe prosthesis subsidence), one case died with tumor and one lost the follow-up. Moreover, at the end of 12 months and 24 months, there was significant difference between the two groups in severe prosthesis subsidence rate (P < 0.01). Conclusion: 3D-printed artificial vertebral body for anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma can provide reliable spinal stability, and reduce the incidence of prosthesis subsidence after 2-year follow-up.

Key words: Cervical chordoma, Total spondylectomy, 3D-printed artificial vertebral body, Titanium mesh cage, Prosthesis subsidence

CLC Number: 

  • R739.9

Figure 1

3D-printed artificial vertebral body for anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma Case 1, female, 47 years old, cervical 2-5 chordoma, 3D printed artificial vertebral body and screws were used in the operation. A, B, anteroposterior and lateral X-rays after operation; C, D, E, lateral X-rays 3 months, 12 months and 24 months after operation."

Figure 2

Titanium mesh cage for anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma Case 2, male, 68 years old, cervical 3-5 chordoma, titanium mesh and plate were used in the operation. A, B, anteroposterior and lateral X-rays after operation; C, D, E, lateral X-rays 3 months, 12 months and 24 months after operation."

1 Casali PG , Stacchiotti S , Sangalli C , et al. Chordoma[J]. Curr Opin Oncol, 2007, 19 (4): 367- 370.
doi: 10.1097/CCO.0b013e3281214448
2 Dea N , Fisher CG , Reynolds JJ , et al. Current treatment strategy for newly diagnosed chordoma of the mobile spine and sacrum: Results of an international survey[J]. J Neurosurg Spine, 2018, 30 (1): 119- 125.
3 Li Z , Wei F , Liu Z , et al. Risk factors for instrumentation failure after total en bloc spondylectomy of thoracic and lumbar spine tumors using titanium mesh cage for anterior reconstruction[J]. World Neurosurg, 2020, 135, 106- 115.
doi: 10.1016/j.wneu.2019.11.057
4 Wei F , Li Z , Liu Z , et al. Upper cervical spine reconstruction using customized 3D-printed vertebral body in 9 patients with primary tumors involving C2[J]. Ann Transl Med, 2020, 8 (6): 332.
doi: 10.21037/atm.2020.03.32
5 Choy WJ , Mobbs RJ , Wilcox B , et al. Reconstruction of thoracic spine using a personalized 3D-printed vertebral body in adolescent with T9 primary bone tumor[J]. World Neurosurg, 2017, 105, 1013- 1032.
6 Xu N , Wei F , Liu X , et al. Reconstruction of the upper cervical spine using a personalized 3D-printed vertebral body in an adolescent with Ewing sarcoma[J]. Spine (Phila Pa 1976), 2016, 41 (1): 50- 54.
doi: 10.1097/BRS.0000000000001179
7 Wei F , Liu Z , Liu X , et al. An approach to primary tumors of the upper cervical spine with spondylectomy using a combined approach: Our experience with 19 cases[J]. Spine (Phila Pa 1976), 2018, 43 (2): 81- 88.
doi: 10.1097/BRS.0000000000001007
8 Hu B , Wang L , Song Y , et al. A comparison of long-term outcomes of nanohydroxyapatite/polyamide-66 cage and titanium mesh cage in anterior cervical corpectomy and fusion: A clinical follow-up study of least 8 years[J]. Clin Neurol Neurosurg, 2019, 176, 25- 29.
doi: 10.1016/j.clineuro.2018.11.015
9 Jin YZ , Zhao B , Lu XD , et al. Mid- and long-term follow-up efficacy analysis of 3D-printed interbody fusion cages for anterior cervical discectomy and fusion[J]. Orthop Surg, 2021, 13 (7): 1969- 1978.
doi: 10.1111/os.13005
10 Zhou H , Jiang L , Wei F , et al. Prognostic factors in surgical patients with chordomas of the cervical spine: A study of 52 cases from a single institution[J]. Ann Surg Oncol, 2017, 24 (8): 2355- 2362.
doi: 10.1245/s10434-017-5884-5
11 Yoshioka K , Murakami H , Demura S , et al. Risk factors of instrumentation failure after multilevel total en bloc spondylectomy[J]. Spine Surg Relat Res, 2017, 1 (1): 31- 39.
doi: 10.22603/ssrr.1.2016-0005
12 Matsumoto M , Watanabe K , Tsuji T , et al. Late instrumentation failure after total en bloc spondylectomy[J]. J Neurosurg Spine, 2011, 15 (3): 320- 327.
doi: 10.3171/2011.5.SPINE10813
13 Huang S , Ji T , Guo W . Biomechanical comparison of a 3D-printed sacrum prosthesis versus rod-screw systems for reconstruction after total sacrectomy: A finite element analysis[J]. Clin Biomech (Bristol, Avon), 2019, 70, 203- 208.
doi: 10.1016/j.clinbiomech.2019.10.019
14 Kaloostian PE , Gokaslan ZL . Surgical management of primary tumors of the cervical spine: Surgical considerations and avoidance of complications[J]. Neurol Res, 2014, 36 (6): 557- 565.
doi: 10.1179/1743132814Y.0000000367
15 Park SJ , Lee CS , Chang BS , et al. Rod fracture and related factors after total en bloc spondylectomy[J]. Spine J, 2019, 19 (10): 1613- 1619.
doi: 10.1016/j.spinee.2019.04.018
16 Zhang T , Wei Q , Zhou H , et al. Three-dimensional-printed individualized porous implants: A new "implant-bone" interface fusion concept for large bone defect treatment[J]. Bioact Mater, 2021, 6 (11): 3659- 3670.
doi: 10.1016/j.bioactmat.2021.03.030
17 Xiu P , Jia Z , Lv J , et al. Tailored surface treatment of 3D printed porous Ti6Al4V by microarc oxidation for enhanced osseointegration via optimized bone in-growth patterns and interlocked bone/implant interface[J]. ACS Appl Mater Interfaces, 2016, 8 (28): 17964- 17975.
doi: 10.1021/acsami.6b05893
18 Girolami M , Boriani S , Bandiera S , et al. Biomimetic 3D-printed custom-made prosthesis for anterior column reconstruction in the thoracolumbar spine, a tailored option following en bloc resection for spinal tumors: Preliminary results on a case-series of 13 patients[J]. Eur Spine J, 2018, 27 (12): 3073- 3083.
doi: 10.1007/s00586-018-5708-8
19 Yang J , Cai H , Lv J , et al. In vivo study of a self-stabilizing artificial vertebral body fabricated by electron beam melting[J]. Spine (Phila Pa 1976), 2014, 39 (8): 486- 492.
doi: 10.1097/BRS.0000000000000211
[1] LI Jun,LIU Xu-hong,WANG Gong,CHENG Cheng,ZHUANG Hong-qing,YANG Rui-jie. Dosimetric effect of patient arm position on Cyberknife radiosurgery for spinal tumors [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 182-186.
[2] Lei LIU,Li-hua WANG,Yu-bo REN,Xiao-song RAO,Shao-min YANG. Clinicopathological analysis of aggressive angiomyxoma of soft tissue in abdomino-pelvic cavity [J]. Journal of Peking University(Health Sciences), 2018, 50(6): 1098-1101.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!