Journal of Peking University(Health Sciences) >
Influence of trueness for local finish lines of a full crown preparation on that of complete finish line
Received date: 2019-07-25
Online published: 2021-02-07
Objective: To investigate the factors affecting the trueness of finish lines of full crown preparations in digital impressions.Methods: A full crown preparation of the right maxillary molar was prepared on the standard resin dentition model, the trueness of the finish lines, the full crown preparation in the whole dentition and the isolated full crown preparation were measured respectively. Detection of scanning trueness of the finish lines of the full crown preparation in the whole dentition: (1) Using Imetric scanner to scan the full crown preparation, obtaining STL (Stereo lithographic) format data as the reference true value; (2) Using CEREC Omnicam oral scanner and 3Shape TRIOS oral scanner to scan the full crown preparation, obtaining all the STL format data, import Geomagic Studio 2013 software, extraction of images and data of the complete finish lines or local finish lines (mesial, distal, buccal, lingual) of the full crown preparation, then using the data to 3D Compare Analysis with the reference true value, outputting RMS (root mean square) values which could evaluate the scanning trueness, the lower RMS value was, the lower the trueness was. The detection of scanning trueness of the finish lines of the isolated full crown preparation: (1) the anterior and posterior adjacent teeth of the preparation were removed to establish the model of the isolated full crown preparation; (2) CEREC Omnicam oral scanner and 3Shape TRIOS oral scanner were used to scan the isolated preparations, and each group was repeated 6 times. Data collection and analysis were the same as the first part, that is, detection of scanning trueness of finish lines of the full crown preparation in the whole dentition.Results: In the whole dentition, (1) the RMS value [(44±7) μm] of CEREC Omnicam oral scanner scanning complete finish lines was greater than that of 3Shape TRIOS oral scanner [(35±6) μm](P<0.05). (2) the RMS values of the mesial [(45±9) μm], buccal [(38±3) μm] and lingual [(40±3) μm] finish lines in CEREC Omnicam oral scanner scanning were all lower than that in distal [(63±7) μm](P<0.05), and the RMS values in mesial were higher than that in buccal and lingual (P>0.05). The RMS values of 3Shape TRIOS oral scanner scanning mesial and distal finish lines were significantly higher than those of the buccal and lingual side (P>0.05), in which:(45±8) μm in mesial, (50±10) μm in the distal, (33±8) μm in the buccal and (33±6) μm in the lingual side. The RMS value of CEREC Omnicam oral scanner scanning distal finish line was greater than that of 3Shape TRIOS oral scanner (P<0.05). Without adjacent teeth, (1) the RMS values of the complete finish lines of CEREC Omnicam oral scanner and 3 Shape TRIOS oral scanner were significantly reduced (P<0.05), including CEREC Omnicam oral scanner (34±3) μm and 3 Shape TRIOS oral scanner (26±4) μm; (2) the RMS values of the buccal and lingual finish lines of CEREC Omnicam oral scanner and 3Shape TRIOS oral scanner showed no significant changes (P>0.05), among which, CEREC Omnicam oral scanner buccal (44±7) μm, lingual (43±3) μm, 3Shape TRIOS oral scanner buccal (29±5) μm, lingual (40±7) μm. The RMS values of CEREC Omnicam oral scanner and 3Shape TRIOS oral scanner were significantly reduced and there was no significant difference between them (P>0.05). CEREC Omnicam oral scanner (32±8) μm and 3Shape TRIOS oral scanner (32±6) μm. The RMS values of the distal finish lines of CEREC Omnicam oral scanner and 3 Shape TRIOS oral scanner also decreased significantly (P<0.05), and CEREC Omnicam oral scanner (38±3) μm decreased more significantly, similar to 3Shape TRIOS oral scanner (36±1) μm, P>0.05.Conclusion: When adjacent teeth exist in the full crown preparation, the mesial and distal parts of the finish line will be blocked by adjacent teeth, which will affect the trueness of the local finish line, and ultimately reduce the trueness of the complete finish line.
Key words: Intraoral scanners; Trueness; Preparation; Finish line
Nan JIANG , Xu-dong BAO , Lin YUE . Influence of trueness for local finish lines of a full crown preparation on that of complete finish line[J]. Journal of Peking University(Health Sciences), 2021 , 53(1) : 102 -108 . DOI: 10.19723/j.issn.1671-167X.2021.01.016
| [1] | Logozzo S, Zanetti EM, Franceschini G, et al. Recent advances in dental optics: Part I. 3D intraoral scanners for restorative dentistry[J]. Opt Laser Eng, 2014,54(3):203-221. |
| [2] | 王勇. 口内数字印模技术[J]. 口腔医学, 2015,35(9):705-709, 743. |
| [3] | 张馨月, 李虹, 赵一姣, 等. 两种结构光口内三维扫描仪获取单冠预备体数据质量的模型评价[J]. 中华口腔医学杂志, 2016,51(7):432-436. |
| [4] | Mangano F, Gandolfi A, Luongo G, et al. Intraoral scanners in dentistry: a review of the current literature[J]. BMC Oral Health, 2017,17(1):1-11. |
| [5] | Lee JJ, Jeong ID, Park JY, et al. Accuracy of single-abutment digital cast obtained using intraoral and cast scanners[J]. J Prosthet Dent, 2016,117(2):253-259. |
| [6] | Mou SH, Chai T, Wang JS, et al. Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns[J]. J Prosthet Dent, 2002,87(3):248-255. |
| [7] | Nedelcu R, Olsson P, Nystr?m I, et al. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison[J]. BMC Oral Health, 2018,18(1):1-11. |
| [8] | Sim J, Jang Y, Kim W, et al. Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows[J]. J Prosthodont Res, 2019,63(1):25-30. |
| [9] | Re D, Cerutti F, Augusti G, et al. Comparison of marginal fit of Lava CAD/CAM crown-copings with two finish lines[J]. Int J Esthet Dent, 2014,9(3):426-435. |
| [10] | Schaefer O, Watts DC, Sigusch BW, et al. Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: A three-dimensional analysis of accuracy and reproducibility[J]. Dental Materials, 2012,28(3):320-326. |
| [11] | 药学与临床研究编辑部. 如何正确运用组内相关系数进行一致性检验: 药物研究中的统计学(一)[J]. 药学与临床研究, 2018,26(1):7-8. |
| [12] | 赵一姣, 王勇. 从工程技术角度谈口腔医学椅旁数字化技术[J]. 中华口腔医学杂志, 2018,53(4):230-235. |
/
| 〈 |
|
〉 |