Journal of Peking University(Health Sciences) ›› 2015, Vol. 47 ›› Issue (6): 1015-1021. doi: 10.3969/j.issn.1671-167X.2015.06.023

• Article • Previous Articles     Next Articles

Finite element analysis of the maxillary central incisor with crown lengthening surgery and post-core restoration in management of crown-root fracture

ZHEN Min1, HU Wen-jie1△, RONG Qi-guo2△   

  1. (1. Department of Periodontology, Peking University School and Hospital of Stomatology, Beijing 100081, China; 2.Department of Mechanics and Engineering Scince, College of Engineering, Peking University, Beijing 100871, China)
  • Online:2015-12-18 Published:2015-12-18
  • Contact: HU Wen-jie1, RONG Qi-guo E-mail:huwenjie@pkuss.bjmu.edu.cn, qrong@pku.edu.cn
  • Supported by:

    Supported by the Capital Foundation for Clinical Characteristics and Application Research(Z131107002213174)

Abstract:

Objective: To construct the finite element models of maxillary central incisor and the simulations with crown lengthening surgery and post-core restoration in management of different crown-root fracture types, to investigate the stress intensity and distributions of these models mentioned above, and to analyze the indications of crown lengthening from the point of view of mechanics. Methods: An extracted maxillary central incisor and alveolar bone plaster model were scanned by Micro-CT and dental impression scanner (3shape D700) respectively. Then the 3D finite element models of the maxillary central incisor and 9 simulations with crown lengthening surgery and postcore restoration were constructed by Mimics 10.0, Geomagic studio 9.0 and ANSYS 14.0 software. The oblique static force (100 N) was applied to the palatal surface (the junctional area of the incisal 1/3 and middle 1/3), at 45 degrees to the longitudinal axis, then the von Mises stress of dentin, periodontal ligament, alveolar bone, post and core, as well as the periodontal ligament area, were calculated. Results: A total of 10 high-precision three-dimensional finite element models of maxillary central incisor were established. The von Mises stress of models: post>dentin>alveolar bone>core>periodontal ligament, and the von Mises stress increased linearly with the augmentation of fracture degree (besides the core). The periodontal ligament area of the crown lengthening was reduced by 12% to 33%. The von Mises stress of periodontal ligament of the B2L2c, B2L3c, B3L1c, B3L2c, B3L3c models exceeded their threshold limit value, respectively. Conclusion: The maxillary central incisors with the labial fracture greater than three-quarter crown length and the palatal fracture deeper than 1 mm below the alveolar crest are not the ideal indications of the crown lengthening surgery.

Key words: Tooth fractures, Crown lengthening, Finite element analysis, Tooth crown, Tooth root

CLC Number: 

  • R781.45
[1] Wei ZHOU,Jin-gang AN,Qi-guo RONG,Yi ZHANG. Three-dimensional finite element analysis of traumatic mechanism of mandibular symphyseal fracture combined with bilateral intracapsular condylar fractures [J]. Journal of Peking University (Health Sciences), 2021, 53(5): 983-989.
[2] Shuang REN,Hui-juan SHI,Jia-hao ZHANG,Zhen-long LIU,Jia-yi SHAO,Jing-xian ZHU,Xiao-qing HU,Hong-shi HUANG,Ying-fang AO. Finite element analysis of the graft stresses after anterior cruciate ligament reconstruction [J]. Journal of Peking University (Health Sciences), 2021, 53(5): 865-870.
[3] JIANG You-sheng,FENG Lin,GAO Xue-jun. Influence of base materials on stress distribution in endodontically treated maxillary premolars restored with endocrowns [J]. Journal of Peking University (Health Sciences), 2021, 53(4): 764-769.
[4] Wei-liang WU,Xiao ZENG,Xiao-qiang LIU,Jian-guo TAN. Esthetic proportions of maxillary anterior teeth of 120 Chinese adults [J]. Journal of Peking University (Health Sciences), 2020, 52(6): 1130-1134.
[5] Xiao-xian CHEN,Jie ZHONG,Wen-juan YAN,Hong-mei ZHANG,Xia JIANG,Qian HUANG,Shi-hua XUE,Xing-gang LIU. Clinical performance of rensin-bonded composite strip crowns in primary incisors [J]. Journal of Peking University (Health Sciences), 2020, 52(5): 907-912.
[6] Chun-ping LIN,Song-he LU,Jun-xin ZHU,Hong-cheng HU,Zhao-guo YUE,Zhi-hui TANG. Influence of thread shapes of custom-made root-analogue implants on stress distribution of peri-implant bone: A three-dimensional finite element analysis [J]. Journal of Peking University(Health Sciences), 2019, 51(6): 1130-1137.
[7] Jia-hao ZHANG,Shuang REN,Jia-yi SHAO,Xing-yue NIU,Xiao-qing HU,Ying-fang AO. Anatomical and finite element analysis of anterior cruciate ligament reconstruction within biomechanical insertion [J]. Journal of Peking University(Health Sciences), 2019, 51(3): 586-590.
[8] Hong-yu FU,Fang-fang WANG,Xiao-mei HOU. Construction and mechanical analysis of finite element model for bending property of controlled memory wire nickel-titanium rotary file [J]. Journal of Peking University(Health Sciences), 2019, 51(1): 131-135.
[9] . Stress change of periodontal ligament of the anterior teeth at the stage of space closure in lingual appliances: a 3-dimensional finite element analysis [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 141-147.
[10] ZHAO Yi-jiao, LIU Yi, SUN Yu-chun, WANG Yong. Three-dimensional data fusion method for tooth crown and root based on curvature continuity algorithm#br# [J]. Journal of Peking University(Health Sciences), 2017, 49(4): 719-723.
[11] ZHAO Yi-jiao, WANG Si-wei, LIU Yi, WANG Yong. A method for rapid extracting three-dimensional root model of vivo tooth from cone beam computed tomography data based on the anatomical characteristics of periodontal ligament [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 54-059.
[12] YANG Xuan,LE Di,ZHANG Yan-ling,LIANG ling-zhi,YANG Gang,HU Wen-jie. Relationship between crown form of upper central incisors and papilla filling in Chinese Han-nationality youth [J]. Journal of Peking University(Health Sciences), 2016, 48(5): 866-870.
[13] WEN Fu-jia,CHEN Gui,LIU Yi. Morphological analysis of roots and alveolar bone changes after upper anterior #br# retraction with maximum anchorage based on cone-beam computed tomography [J]. Journal of Peking University(Health Sciences), 2016, 48(4): 702-708.
[14] ZHAO Xu, ZHANG Lei, SUN Jian, YANG Zhen-yu, XIE Qiu-fei. Three-dimensional finite element analysis of influence of occlusal surface height on stress distribution around posterior implant-supported single crown [J]. Journal of Peking University(Health Sciences), 2016, 48(1): 94-100.
[15] JIA Xue-ting, ZHEN Min, HU Wen-jie, LIU Yun-song. Different multidisciplinary approaches of two traumatic teeth fractures in the esthetic zone: a case report [J]. Journal of Peking University(Health Sciences), 2015, 47(5): 878-882.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. Journal of Peking University(Health Sciences), 2009, 41(4): 456 -458 .
[2] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 125 -128 .
[3] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 135 -140 .
[4] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 158 -161 .
[5] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 217 -220 .
[6] . [J]. Journal of Peking University(Health Sciences), 2009, 41(1): 52 -55 .
[7] . [J]. Journal of Peking University(Health Sciences), 2009, 41(1): 109 -111 .
[8] . [J]. Journal of Peking University(Health Sciences), 2009, 41(3): 297 -301 .
[9] . [J]. Journal of Peking University(Health Sciences), 2009, 41(5): 505 -515 .
[10] . [J]. Journal of Peking University(Health Sciences), 2009, 41(5): 599 -601 .