Three-dimensional finite element analysis of influence of occlusal surface height on stress distribution around posterior implant-supported single crown

ZHAO Xu1, ZHANG Lei1△, SUN Jian2, YANG Zhen-yu2, XIE Qiu-fei1   

  1. (1. Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China; 2. Institute of Solid Mechanics,School of Aeronautics Sciences and Engineering, Beihang University, Beijing 100191, China)
  • Online:2016-02-18 Published:2016-02-18
  • Contact: ZHANG Lei E-mail:drzhanglei@yeah.net

Abstract:

Objective:To evaluate the effect of the occlusal surface height of a mandibular posterior implant-supported single crown on stress in bone tissues. Methods: Three-dimensional finite element models of the implant-supported single crown replacing the missing right lower second premolar, mesial and distal natural teeth, periodontal membrane, alveolar bone, loaded rigid body and analog food of almond were established. Using the Federation Dentaire International (FDI) system, the first premolar, the second premolar and the first molar were represented with 44, 45, 46. Three occlusal surface heights of the crown were studied: (1) normal height; (2) 15 μm reduction in height; (3) 30 μm reduction in height. The models were loaded by independent loading with maximal occlusal force(44 by 280 N, 45 by 360 N, and 46 by 480 N)and average occlusal force(44 by 140 N, 45 by 180 N, and 46 by 240 N)on the single crown; combined loading (maximal occlusal force transformed into uniform load of 3.7 MPa on top of rigid body, in contact with points on the occlusal surface), and analog almondlike food loading (average occlusal force transformed into uniform load of 1.67 MPa in simulated food chewing, in contact with points on the occlusal surface). Results: For maximal biting force under independent loading, Von Mises stress peak values in bone tissues around 44, 45, and 46 were 82.57 MPa, 45.26 MPa and 27.79 MPa; For average biting force, peak values were 41.28 MPa, 22.63 MPa and 13.89 MPa. Under combined loading, compared with the normal occlusal surface height group, Von Mises stress peak values decreased 4.6 MPa, by 0.84%; increased 7.52 MPa, by 20.04%, and decreased 1.8 MPa, by 5.84%, for 45, 46, and 44 in the 30 μm infra-occlusion group, respectively. Under food loading, Von Mises stress peak values decreased 0.34 MPa, by 1.62%; increased 1.11 MPa, by 2.66%; and increased 0.06 MPa, by 0.54%, and for 45, 46, and 44 in the 30 μm infra-occlusion group, respectively. Conclusion:Within the limitation of this study, within 30 μm reduction of the occlusal surface height of implantsupported single crown, no significant difference of the peak values was observed.

Key words: Implant-supported single crown, Occlusal surface height, Loading method, Finite element analysis, Stress

CLC Number: 

  • R781.33
[1] Yuqing LI,Biao WANG,Peng QIAO,Wei WANG,Xing GUAN. Medium to long-term efficacy of tension-free vaginal tape procedure in the treatment of female recurrent stress urinary incontinence [J]. Journal of Peking University (Health Sciences), 2024, 56(4): 600-604.
[2] Xiaoqian SI,Xiujuan ZHAO,Fengxue ZHU,Tianbing WANG. Risk factors for acute respiratory distress syndrome in patients with traumatic hemorrhagic shock [J]. Journal of Peking University (Health Sciences), 2024, 56(2): 307-312.
[3] Zhi-wei LIU,Peng LIU,Fan-xing MENG,Tian-shui LI,Ying WANG,Jia-qi GAO,Zuo-yi ZHOU,Cong WANG,Bin ZHAO. Regulative effects of endogenous sulfur dioxide on oxidant stress in myocardium of rat with sepsis [J]. Journal of Peking University (Health Sciences), 2023, 55(4): 582-586.
[4] Yu-xin WANG,Yu-han DENG,Yin-liang TAN,Bao-hua LIU. Predictive value of stress-induced hyperglycemia on 28 d risk of all-cause death in intensive care patients [J]. Journal of Peking University (Health Sciences), 2023, 55(3): 442-449.
[5] Meng-en OU,Yun DING,Wei-feng TANG,Yong-sheng ZHOU. Three-dimensional finite element analysis of cement flow in abutment margin-crown platform switching [J]. Journal of Peking University (Health Sciences), 2023, 55(3): 548-552.
[6] Shuang REN,Hui-juan SHI,Jia-hao ZHANG,Zhen-long LIU,Jia-yi SHAO,Jing-xian ZHU,Xiao-qing HU,Hong-shi HUANG,Ying-fang AO. Finite element analysis of the graft stresses after anterior cruciate ligament reconstruction [J]. Journal of Peking University (Health Sciences), 2021, 53(5): 865-870.
[7] Wei ZHOU,Jin-gang AN,Qi-guo RONG,Yi ZHANG. Three-dimensional finite element analysis of traumatic mechanism of mandibular symphyseal fracture combined with bilateral intracapsular condylar fractures [J]. Journal of Peking University (Health Sciences), 2021, 53(5): 983-989.
[8] JIANG You-sheng,FENG Lin,GAO Xue-jun. Influence of base materials on stress distribution in endodontically treated maxillary premolars restored with endocrowns [J]. Journal of Peking University (Health Sciences), 2021, 53(4): 764-769.
[9] BAI Feng,HE Yi-fan,NIU Ya-nan,YANG Ruo-juan,CAO Jing. Effects of ultrafine particulates on cardiac function in rat isolated heart [J]. Journal of Peking University (Health Sciences), 2021, 53(2): 240-245.
[10] Yan XUAN,Yu CAI,Xiao-xuan WANG,Qiao SHI,Li-xin QIU,Qing-xian LUAN. Effect of Porphyromonas gingivalis infection on atherosclerosis in apolipoprotein-E knockout mice [J]. Journal of Peking University (Health Sciences), 2020, 52(4): 743-749.
[11] Chun-ping LIN,Song-he LU,Jun-xin ZHU,Hong-cheng HU,Zhao-guo YUE,Zhi-hui TANG. Influence of thread shapes of custom-made root-analogue implants on stress distribution of peri-implant bone: A three-dimensional finite element analysis [J]. Journal of Peking University(Health Sciences), 2019, 51(6): 1130-1137.
[12] Xian-hui LIU,Wei-yu ZHANG,Hao HU,Qi WANG,Tao WANG,Yong-xin HE,Ke-xin XU. Long-term follow-up of the efficacy of tension-free vaginal tape and trans-obturator tape for different types of stress urinary incontinence [J]. Journal of Peking University(Health Sciences), 2019, 51(4): 694-697.
[13] Jia-hao ZHANG,Shuang REN,Jia-yi SHAO,Xing-yue NIU,Xiao-qing HU,Ying-fang AO. Anatomical and finite element analysis of anterior cruciate ligament reconstruction within biomechanical insertion [J]. Journal of Peking University(Health Sciences), 2019, 51(3): 586-590.
[14] Hong-yu FU,Fang-fang WANG,Xiao-mei HOU. Construction and mechanical analysis of finite element model for bending property of controlled memory wire nickel-titanium rotary file [J]. Journal of Peking University(Health Sciences), 2019, 51(1): 131-135.
[15] Jia-xuan XU,Hong-zhi WANG,Jun DONG,Xiao-jie CHEN,Yong YANG,Ren-xiong CHEN,Guo-dong WANG. Analysis of risk factors for acute lung injury/acute respiratory distress syndrome after esophagectomy [J]. Journal of Peking University(Health Sciences), 2018, 50(6): 1057-1062.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!