Journal of Peking University(Health Sciences) ›› 2018, Vol. 50 ›› Issue (3): 547-552. doi: 10.3969/j.issn.1671-167X.2018.03.026

• Article • Previous Articles     Next Articles

Detection of root cracks after root canal preparation using rotary NiTi systems by optical coherence tomography (OCT) scan

CHEN Chen1*, ZHANG Wen-xin 2, QI Li-yuan 1, GAO Xue-jun1, LIANG Yu-hong1,3△   

  1. (1. Department of Cariology and Endodontology,Peking University School and Hospital of Stomatology & Natioual Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China; 2. Department of Physics, Tsinghua University, Beijing 100084, China; 3. Department of Stomatology, Peking University International Hospital, Beijing 102206, China)
  • Online:2018-06-18 Published:2018-06-18
  • Contact: LIANG Yu-hong E-mail:leungyuhong@sina.com

Abstract: Objective: To evaluate the accuracy of optical coherence tomography (OCT) in detecting root cracks after root canal instrumentation using histological gold standard. Methods: Twenty complete extracted human mandibular incisors that were free of caries, calculus, and root treatment were chosen and accessed coronally with a diamond bur, then mounted in resin blocks with alginate impression material using simulated periodontal ligaments, and the apex was exposed 3 mm. The teeth were stored in water at room temperature. Then the teeth were then instrumented to the major apical foramen (AF) at #30/0.09 using ProTaper Universal rotary nickel titanium system(Dentsply Maillefer, Ballaigues, Switzerland), irrigation with 1% sodium hypochlorite (NaOCl) by using a 26gauge needle followed after each instrument. The apical root was scanned with 360° of rotation by Swept-Source Optical Coherence Tomography (SS-OCT) (wavelength: 1 310 nm, scan rate: 20 kHz, axial resolution: 16 μm) with driving device(stepper motor and lifting platform). The reconstruction images of axial planes 1, 2 and 3 mm from the apex were examined and the root cracks were blindly diagnosed by two observers. The horizontal section was performed at 1, 2 and 3 mm from the apex using low speed disc saw (Leica SP1600, Wetzlar, Germany). The presence of cracks was noted under an optical stereomicroscope (ZOOM-630E) with a cold light source using as gold standard to evaluate the accuracy of OCT in detecting root cracks after root canal instrumentation. Results: After canals instrumentation with ProTaper Universal rotary nickel titanium system to #30/0.09, root cracks were detected in 9 of 20 teeth by histological examination. Crack lines were observed on 13 of 60 horizontal sections and cracks on 12 of the 13 sections were detected by OCT. No cracks were observed in the other 47 of the 60 horizontal sections,none of which was misdiagnosed by OCT. The overall accuracy rate for detection of root cracks with OCT was 0.983, the sensitivity was 0.923, the specificity was 1.000, the positive predictive value (PPV) was 1.000 and the negative predictive value (NPV) was 0.979. Conclusion: OCT may be a promising nondestructive imaging method for diagnosing root canal cracks after canal instrumentation.

Key words: Optical coherence tomography (OCT), Root canal preparation, Root crack

CLC Number: 

  •  
[1] YANG Yin-jie, HOU Ben-xiang, HOU Xiao-mei. Effect of autoclave on surface microstructure and cyclic fatigue resistance of R-phase rotary instruments#br# [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 882-886.
[2] TIAN Shi-yu, BAI Wei, LIANG Yu-hong. Impact of apical preparation diameter on fracture resistance of mandibular premolar roots [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 92-095.
[3] SU Zheng, BAI Yu-hao, HOU Xiao-mei. Effects of different techniques on removal of vapor lock in the apical region of curved canals: a cone-beam computed tomography study [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 76-080.
[4] CHEN Xiao-bo, CHEN Chen, LIANG Yu-hong. Comparison of effectiveness and safety between Twisted File technique and ProTaper Universal rotary full sequence based on micro-computed tomography [J]. Journal of Peking University(Health Sciences), 2016, 48(1): 101-104.
[5] CHEN Chen, LIANG Yu-Hong, GAO Xue-Jun. Comparison of the incidences of apical root cracks after canal preparation with two nickel-titanium rotary systems: an in vitro study [J]. Journal of Peking University(Health Sciences), 2015, 47(1): 129-133.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!