Abstract:

Objective: To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT).Methods: Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25×magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Threedimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared.Results:The shorter preparation time [(0.53±0.14) min] was observed in TF group, while the preparation time of PU group was (2.06±0.39) min (P<0.05). In mid-root level, TF group shaping resulted in less canal center transportation than PU group [(0.070±0.056) mm vs. (0.097±0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25× magnification.  Conclusion:Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.

Key words: Nickel, Titanium, Alloys, Root canal preparation, X-Ray microtomography

CLC Number: 

  • R781.33
[1] Jia-qi SHI,Ying MA,Yi ZHANG,Zhang-jian CHEN,Guang JIA. Effects of titanium dioxide nanoparticles on circRNA expression profiles in human hepatocellular carcinoma cells HepG2 [J]. Journal of Peking University (Health Sciences), 2023, 55(3): 392-399.
[2] Hua ZHOU,Ren-ji WANG,Zhong-jun LIU,Xiao-guang LIU,Feng-liang WU,Lei DANG,Feng WEI. 3D-printed vertebral body in anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma [J]. Journal of Peking University (Health Sciences), 2023, 55(1): 144-148.
[3] Jia-he ZHANG,Jia-qi SHI,Zhang-jian CHEN,Guang JIA. Effects of nano titanium dioxide on gut microbiota based on human digestive tract microecology simulation system in vitro [J]. Journal of Peking University (Health Sciences), 2022, 54(3): 468-476.
[4] Di ZHOU,Zhang-jian CHEN,Gui-ping HU,Teng-long YAN,Chang-mao LONG,Hui-min FENG,Guang JIA. Influence of oxidative/antioxidative biomarkers and inflammatory cytokines on rats after sub-acute orally administration of titanium dioxide nanoparticles [J]. Journal of Peking University (Health Sciences), 2020, 52(5): 821-827.
[5] Shuo HAN,Zhang-jian CHEN,Di ZHOU,Pai ZHENG,Jia-he ZHANG,Guang JIA. Effects of titanium dioxide nanoparticles on fecal metabolome in rats after oral administration for 90 days [J]. Journal of Peking University (Health Sciences), 2020, 52(3): 457-463.
[6] Zhang-jian CHEN,Shuo HAN,Pai ZHENG,Shu-pei ZHOU,Guang JIA. Effect of subchronic combined oral exposure of titanium dioxide nanoparticles and glucose on levels of serum folate and vitamin B12 in young SD rats [J]. Journal of Peking University (Health Sciences), 2020, 52(3): 451-456.
[7] Bei-bei LI,Ping DI. Effects of CAD/CAM titanium alloy surface treatment and resin luting on shear bond strength and durability of composite resin [J]. Journal of Peking University(Health Sciences), 2019, 51(1): 111-114.
[8] YANG Yin-jie, HOU Ben-xiang, HOU Xiao-mei. Effect of autoclave on surface microstructure and cyclic fatigue resistance of R-phase rotary instruments#br# [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 882-886.
[9] WANG Fang-fang, YANG Yin-jie, HOU Xiao-mei. Surface microstructure and cyclic fatigue resistance of electro discharged machining nickel-titanium endodontic instrument [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 876-881.
[10] CHEN Chen, ZHANG Wen-xin,QI Li-yuan,GAO Xue-jun, LIANG Yu-hong. Detection of root cracks after root canal preparation using rotary NiTi systems by optical coherence tomography (OCT) scan [J]. Journal of Peking University(Health Sciences), 2018, 50(3): 547-552.
[11] DUAN Shu-min, ZHANG Yong-liang, WANG Yun. Effects of titanium dioxide nanoparticles and lipopolysaccharide on antioxidant function of liver tissues in mice [J]. Journal of Peking University(Health Sciences), 2018, 50(3): 395-400.
[12] HAN Yi, BAI Yu-hao, HOU Xiao-mei. Glide path management of rotary nickel-titanium instruments in simulated root canals [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 148-153.
[13] ZHANG Yong-liang, CHEN Zhang-jian, CHEN Shi, ZHUO lin, JIA Guang, WANG Yun. Effect of nano-TiO2 on intestinal glucose absorption in young rat on the everted gut sac model [J]. Journal of Peking University(Health Sciences), 2017, 49(3): 376-382.
[14] TIAN Shi-yu, BAI Wei, LIANG Yu-hong. Impact of apical preparation diameter on fracture resistance of mandibular premolar roots [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 92-095.
[15] SU Zheng, BAI Yu-hao, HOU Xiao-mei. Effects of different techniques on removal of vapor lock in the apical region of curved canals: a cone-beam computed tomography study [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 76-080.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!