Journal of Peking University(Health Sciences) ›› 2018, Vol. 50 ›› Issue (3): 482-487. doi: 10.3969/j.issn.1671-167X.2018.03.015

• Article • Previous Articles     Next Articles

Effects of high-efficiency particulate air purifiers on indoor fine particulate matter and its constituents in a district of Beijing during winter

CHU Meng-tian, DONG Wei, CHI Rui, PAN Lu, LI Hong-yu, HU Da-yu, YANG Xuan, DENG Fu-rong△, GUO Xin-biao   

  1. (Department of Occupational and Environmental Health Sciences, Peking University School of Public Health, Beijing 100191, China)
  • Online:2018-06-18 Published:2018-06-18
  • Contact: DENG Fu-rong E-mail:lotus321321@126.com
  • Supported by:
    Supported by the Grants of the National Key Research and Development Program of China (2016YFC0206506, 2017YFC0702701), the Grant of China Medical Board (CMB 15-228), and the National Natural Science Foundation of China (81571130090, 91543112)

Abstract: Objective: To analyze the effect of domestic high-efficiency particulate air (HEPA) puri-fiers on the concentrations of indoor fine particulate matter (PM2.5) and its elementary constituents in 20 residences in a district of Beijing during winter. Methods: From November 2015 to January 2016, 20 residences in a district of Beijing were selected, where indoor and outdoor PM2.5 data were collected simultaneously in three time periods according to the operating of air purifiers (Group 0 h: 24 hours before operating; Group 24 h: 24 hours after operating; Group 48 h: 24 to 48 hours after operating). The content of 21 elements in PM2.5 samples were determined by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICPOES). Indoor/outdoor particle concentration ratio (I/O ratios) and ΔI/O ratios were used to describe the pollution levels and the variation range of PM2.5 and its 21 elementary constituents. One-way analysis of variance (ANOVA) for repeated measurement data was applied to compare the I/O ratios of PM2.5 and its elementary constituents among the different groups, and Bonferroni method was used for comparison in pairs. Wilcoxon signed rank test for paired-samples was used to compare ΔI/O ratios of 21 elementary consti-tuents with that of PM2.5. Results: The median I/O ratios of PM2.5 in the three groups were 1.27 (P25-P75: 0.50-2.68), 0.45 (P25-P75: 0.27-1.03) and 0.36 (P25-P75: 0.28-2.48), respectively. Compared with Group 0 h, the I/O ratios of PM2.5 in Group 24 h (P=0.042) and Group 48 h (P=0.006) decreased significantly. However, there was no significant difference between Group 24 h and Group 48 h. Significant differences were found comparing ΔI/O ratios of aluminium, ferrum and titanium to that of PM2.5, in both Group 24 h and Group 48 h (P<0.05). No significant change was found in the I/O ratios of these three elements among the three groups before and after air purifier operating (P>0.05). Distances from residences to traffic arteries could affect I/O ratios of some elements from trafficrelated source (P<0.05). Conclusion: Domestic HEPA air purifiers could effectively reduce indoor PM2.5 concentration, and the pollution level of PM2.5 tend to be stable after the purifier operating for a time. The purifiers had different effects on different elements, among which most showed statistical significances.

Key words: Air pollutants, Particulate matter, Environmental exposure, Elements, Air pollution, indoor, I/O ratio

CLC Number: 

  •  
[1] Huangda GUO,Hexiang PENG,Siyue WANG,Tianjiao HOU,Yixin LI,Hanyu ZHANG,Mengying WANG,Yiqun WU,Xueying QIN,Xun TANG,Jing LI,Dafang CHEN,Yonghua HU,Tao WU. A ssociations of short-term ambient particulate matter exposure and MTNR1B gene with triglyceride-glucose index: A family-based study [J]. Journal of Peking University (Health Sciences), 2024, 56(3): 375-383.
[2] ZHANG Hong,DONG Ji-yuan,WANG Jian-jun,FAN Lin-xia,QU Qiang,LIU Yang. Short-term effects and seasonal variation of ozone on daily hospital outpatient visits for childhood asthma in Lanzhou [J]. Journal of Peking University (Health Sciences), 2022, 54(2): 227-235.
[3] WU Xiao-yin, LI Guo-xing, WANG Xu-ying, LIANG Feng-chao, PAN Xiao-chuan. Correlation study between respiratory death and airborne particles in Beijing: Spa-tiotemporal analysis based on satellite remote sensing data [J]. Journal of Peking University(Health Sciences), 2017, 49(3): 409-417.
[4] ZHANG Yi1, SONG Xiao-ming1, ZHAO Qian, WANG Tong, Li Li-juan, CHEN Jie, XU Hong-bing, LIU Bei-bei, SUN Xiao-yan, HE Bei, HUANG Wei. Effects of exposure to ambient particulate matter and polycyclic aromatic hydrocarbons on oxidative stress biomarkers in the patients with chronic obstructive pulmonary disease [J]. Journal of Peking University(Health Sciences), 2017, 49(3): 394-402.
[5] FAN Ai-qin, FENG Jin-qiu, LIU Wei, ZHANG Min-jia, LIU Tan, ZHOU Ya-lin, XU Ya-jun. Antagonistic effect of quercetin on PM2.5 toxicity in the rat’s embryonic development in vitro [J]. Journal of Peking University(Health Sciences), 2017, 49(3): 388-393.
[6] HUANG Jing, GUO Bin, GUO Xin-Biao. Research progress in health impact of traffic noise [J]. Journal of Peking University(Health Sciences), 2015, 47(3): 555-558.
[7] YI Tie-Ci, LI Jian-Ping. Adverse effects of ultrafine particles on the cardiovascular system and its mechanisms [J]. Journal of Peking University(Health Sciences), 2014, 46(6): 996-1000.
[8] NI Yang, TU Xing-Ying, ZHU Yi-Dan, GUO Xin-Biao, DENG Fu-Rong. Concentrations of fine particulate matters and ultrafine particles and influenced actors during winter in an area of Beijing [J]. Journal of Peking University(Health Sciences), 2014, 46(3): 389-394.
[9] LIU Duo-Jian, WU Jing, Liu-Ya-Qiong, 欧Yang-Li , WANG Jing-Yu. Effects of lead exposure on 18 elements in blood and excretions in rats [J]. Journal of Peking University(Health Sciences), 2014, 46(2): 232-236.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!