Journal of Peking University(Health Sciences) ›› 2019, Vol. 51 ›› Issue (6): 1119-1123. doi: 10.19723/j.issn.1671-167X.2019.06.025

Previous Articles     Next Articles

Quantitative analysis of occlusal changes in posterior partial fixed implant supported prostheses

Qiang LUO1,Qian DING2,Lei ZHANG2,(),Qiu-fei XIE2   

  1. 1. Institute of Stomatology, General Hospital of Chinese PLA, Beijing 100853, China
    2. Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
  • Received:2017-10-23 Online:2019-12-18 Published:2019-12-19
  • Contact: Lei ZHANG E-mail:drzhanglei@yeah.net
  • Supported by:
    Supported by the National Natural Science Foundation of China(81671026);the Capital Health Development Research Special(2014-4-4105)

RICH HTML

  

Abstract:

Objective: To analyze changes in occlusal force distribution and occlusal contact in poste-rior partial fixed implant-supported prostheses over time, and to provide reference for the precise occlusion design, adjustment and maintenance of implant prostheses.Methods: According to certain inclusion and exclusion criteria, patients were recruited from partially edentulous patients who had received implant-supported single crown or fixed bridge in the posterior region. The patients were collected since the implant prostheses settling and scheduled for the routine examination of implant prostheses and the occlusal examinations of complete dentition after 2 weeks, 3, 6, and 12 months. Occlusal examinations were taken with the articulating papers and T-Scan Ⅲ ? (Tekscan, South Boston, USA), which could check and measure the occlusal contact condition of complete dentition. The occlusion time and relative occlusal forces of implant prostheses, mesial adjacent teeth and control teeth were recorded at the same time.Results: Thirty-seven posterior partial fixed implant prostheses in 33 patients (17 women and 16 men, aged 24-70 years) were followed up for 3-12 months (average 8.3 months). At baseline, the relative occlusal forces of implant prostheses were significantly lower than those of the corresponding control teeth (P<0.001). However, after 3 months, the relative occlusal forces of implant prostheses had significantly increased (P<0.05), while control teeth decreased significantly (P<0.05), resulting in no statistical significance between them. The implant prostheses occlusion time ratio also increased significantly from 2 weeks to 3 months (P<0.05). There was no significant difference from the third month to the sixth month, or from the sixth month to the twelfth month (P>0.05).Conclusion: Light contact and time-delayed occlusion of posterior implant prostheses changes significantly in the first three months after settling implant prostheses. These changes mainly include the advance of the time point of the implant prosthesis to start the occlusion contact, and the increase of the occlusal force of the implant prosthesis. The occlusion of posterior implant prostheses should be carefully monitored at end of the third month follow-up clinically.

Key words: Dental prosthesis, Dental occlusion, Dental implantation, Occlusal adjustment

CLC Number: 

  • R783.3

Figure 1

T-scan occlusal examination (A), digital images illustrating maximum intercuspation with corresponding articulating paper mark (B)"

Figure 2

The record of occlusion time from the beginning of bite to the balanced and stable occlusion position of dentition A point, the first occlusal contact of natural teeth; B point, the time of the balanced and stable occlusion position; A’ point, the first occlusal contact of implant prostheses. Implant occlusion time means the time from A’ point to B point."

Table 1

The comparisons of relative occlusal force between implant prostheses and control natural teeth over time"

Time points Implant
prostheses/%,
median (min, max)
Control
natural teeth/%,
median (min, max)
P
2 weeks (n=37) 7 (1, 18) 14 (3, 28) <0.001
3 months (n=27) 9 (1, 25) 11 (5, 24) 0.247
6 months (n=25) 9 (2, 25) 13 (3, 23) 0.156
12 months (n=14) 10 (3, 20) 14 (5, 28) 0.140

Figure 3

Relative occlusal force changes of mesial teeth, implant prostheses and control teeth over time A, from 2 weeks to 3 months; B, from 3 months to 6 months; C, from 6 months to 12 months."

Table 2

The statistical correlation between implant prostheses relative occlusal force and implant occlusion time ratio"

Time points Implant prostheses relative occlusal force/%,
median (min, max)
Implant occlusion time ratio,
median (min, max)
R P
2 weeks (n=37) 7 (1, 18) 0.44 (0.08, 1.00) 0.447 0.006
3 months (n=27) 9 (1, 25) 0.64 (0.11, 1.00) 0.714 <0.001
6 months (n=25) 9 (2, 25) 0.70 (0.19, 0.96) 0.497 0.011
12 months (n=14) 10 (3, 20) 0.83 (0.22, 0.93) 0.113 0.700

Figure 4

Longtitudinal changes of implant prostheses occlusion time ratio"

[1] Zembic A, Kim S, Zwahlen M , et al. Systematic review of the survival rate and incidence of biologic, technical, and esthetic complications of single implant abutments supporting fixed prostheses[J]. Int J Oral Maxillofac Implants, 2014,29(Suppl):99-116.
[2] Velzen FJ, Ofec R, Schulten EA , et al. 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients[J]. Clin Oral Implants Res, 2015,26(10):1121-1128.
[3] Jung RE, Zembic A, Pjetursson BE , et al. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years[J]. Clin Oral Implants Res, 2012,23(Suppl 6):2-21.
[4] Lee JH, Lee JB, Park JI , et al. Mechanical complication rates and optimal horizontal distance of the most distally positioned implant-supported single crowns in the posterior region: a study with a mean follow-up of 3 years[J]. J Prosthodont, 2015,24(7):517-524.
[5] Anner R, Grossmann Y, Anner Y , et al. Smoking, diabetes mellitus, periodontitis, and supportive periodontal treatment as factors associated with dental implant survival: a long-term retrospective evaluation of patients followed for up to 10 years[J]. Implant Dent, 2010,19(1):57-64.
[6] Kim Y, Oh TJ, Misch CE , et al. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale[J]. Clin Oral Implants Res, 2005,16(1):26-35.
[7] Goodacre CJ, Bernal G, Rungcharassaeng K , et al. Clinical complications with implants and implant prostheses[J]. J Prosthet Dent, 2003,90(2):121-132.
[8] Yuan JC, Sukotjo C . Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts[J]. J Periodontal Implant Sci, 2013,43(2):51-57.
[9] Bocklage R . Biomechanical aspects of monoblock implant bridges for the edentulous maxilla and mandible: concepts of occlusion and articulation[J]. Implant Dent, 2004,13(1):49-53.
[10] Kerstein RB . Nonsimultaneous tooth contact in combined implant and natural tooth occlusal schemes[J]. Pract Proced Aesthet Dent, 2001,13(9):751-755.
[11] Stevens CJ . Computerized occlusal implant management with the T-Scan II System: a case report[J]. Dent Today, 2006,25(2):88-91.
[12] Lewis MB, Klineberg I . Prosthodontic considerations designed to optimize outcomes for single-tooth implants. A review of the literature[J]. Aust Dent J, 2011,56(2):181-192.
[13] Roberts SD, Kapadia H, Greenlee G , et al. Midfacial and dental changes associated with nasal positive airway pressure in children with obstructive sleep apnea and craniofacial conditions[J]. J Clin Sleep Med, 2016,12(4):469-475.
[14] D’Incau E, Couture C, Maureille B . Human tooth wear in the past and the present: tribological mechanisms, scoring systems, dental and skeletal compensations[J]. Arch Oral Biol, 2012,57(3):214-229.
[15] Mundhe K, Jain V, Pruthi G , et al. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns[J]. J Prosthet Dent, 2015,114(3):358-365.
[16] Palaniappan S, Elsen L, Lijnen I , et al. Nanohybrid and microfilled hybrid versus conventional hybrid composite restorations: 5-year clinical wear performance[J]. Clinl Oral Investig, 2012,16(1):181-190.
[17] Heij DG, Opdebeeck H, van Steenberghe D, et al. Facial deve-lopment, continuous tooth eruption, and mesial drift as compromising factors for implant placement[J]. Int J Oral Maxillofac Implants, 2006,21(6):867-878.
[18] Schulte W . Implants and the periodontium[J]. Int Dent J, 1995,45(1):16-26.
[19] Kerstein RB, Radke J . Clinician accuracy when subjectively interpreting articulating paper markings[J]. Cranio, 2014,32(1):13-23.
[20] Koos B, Godt A, Schille C , et al. Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch[J]. J Orofac Orthop, 2010,71(6):403-410.
[1] Sui LI,Wenjie MA,Shimin WANG,Qian DING,Yao SUN,Lei ZHANG. Trueness of different digital design methods for incisal guidance of maxillary anterior implant-supported single crowns [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 81-87.
[2] Xiaoqiang LIU,Yin ZHOU. Risk factors of perioperative hypertension in dental implant surgeries with bone augmentation [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 93-98.
[3] Meng-en OU,Yun DING,Wei-feng TANG,Yong-sheng ZHOU. Three-dimensional finite element analysis of cement flow in abutment margin-crown platform switching [J]. Journal of Peking University (Health Sciences), 2023, 55(3): 548-552.
[4] MA Ke-nan,CHEN Hu,SHEN Yan-ru,ZHOU Yong-sheng,WANG Yong,SUN Yu-chun. Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 105-112.
[5] WANG Juan,YU Hua-jie,SUN Jing-de,QIU Li-xin. Application evaluation of prefabricated rigid connecting bar in implants immediate impression preparation of edentulous jaw [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 187-192.
[6] SUN Yu-chun,GUO Yu-qing,CHEN Hu,DENG Ke-hui,LI Wei-wei. Independent innovation research, development and transformation of precise bionic repair technology for oral prosthesis [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 7-12.
[7] Feng LIANG,Min-jie WU,Li-dong ZOU. Clinical observation of the curative effect after 5-year follow-up of single tooth implant-supported restorations in the posterior region [J]. Journal of Peking University (Health Sciences), 2021, 53(5): 970-976.
[8] LIU Xiao-qiang,YANG Yang,ZHOU Jian-feng,LIU Jian-zhang,TAN Jian-guo. Blood pressure and heart rate changes of 640 single dental implant surgeries [J]. Journal of Peking University (Health Sciences), 2021, 53(2): 390-395.
[9] Ke-yi HAO,Jia LUO,Ping DI,Hou-zuo GUO,Hui-dan SHEN,Yan-ping LIU,Yu ZHANG,Ye LIN. Validation of the digital integration technology for evaluating the nasolabial morphology variation after the cross-arch fixed restoration of maxillary implant-supported prostheses [J]. Journal of Peking University (Health Sciences), 2020, 52(5): 924-930.
[10] Wei-ting LI,Peng LI,Mu-zi PIAO,Fang ZHANG,Jie DI. Study on bone volume harvested from the implant sites with different methods [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 103-106.
[11] Lin-lin LI,Yi-jiao ZHAO,Hu CHEN,Yong WANG,Yu-chun SUN. Accuracy of intercuspal occlusion in 3D reconstruction with the dental articulator position method [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 138-143.
[12] Ning XIAO,Yu-chun SUN,Yi-jiao ZHAO,Yong WANG. Preliminary study on three digital analysis methods for analyzing the distribution and area of occlusal contacts [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 144-151.
[13] CHAI Jin-you, LIU Jian-zhang, WANG Bing, QU Jian, SUN Zhen, GAO Wen-hui, GUO Tian-hao, FENG Hai-lan, PAN Shao-xia. Evaluation of the fabrication deviation of a kind of milling digital implant surgical guides#br# [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 892-898.
[14] WU Min-jie, ZOU Li-dong, LIANG Feng. Clinical observation on soft and hard tissue changes of immediate implantation and immediate reconstruction in anterior region after loading 3 years [J]. Journal of Peking University(Health Sciences), 2018, 50(4): 694-699.
[15] ZHANG Hai-dong, ZHANG Li, SHI Dong, HAN Jie, YAN Xia, XIE Ye-si, MENG Huan-xin. Clinical study of locking-taper implants in patients treated for periodontitis [J]. Journal of Peking University(Health Sciences), 2018, 50(2): 300-307.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!