Journal of Peking University(Health Sciences) ›› 2014, Vol. 46 ›› Issue (1): 76-80.

• Articles • Previous Articles     Next Articles

Evaluation of measurement accuracy of three facial scanners based on different scanning principles

ZHAO Yi-jiao, XIONG Yu-xue, YANG Hui-fang, WANG Yong△   

  1. (Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry, Ministry of Health, Beijing 100081, China)
  • Online:2014-02-18 Published:2014-02-18

Abstract: Objective:To evaluate and compare the measurement accuracy of three facial scanners, based on different scanning principles: line laser, structured light and stereophotography. Methods:Three-dimensional (3D) digital face models of the same plaster head model were obtained by three facial scanners separately. The measurement values of the length of 10 feature lines and the angle of 5 feature angles were measured on these 3D models in the software respectively. The standard values of these characteristics were measured by a coordinate measure machine (CMM) with high accuracy. Statistical and surveying analyses were made between the measurement values and standard values. Facial morphology theory measurement accuracy of these three facial scanners was obtained finally. Results:There was no statistical significant difference between the measurement values from the three facial scanners and the standard value from CMM. The 3dMD and Faro scanners were better in length measurements and the length measurement accuracy was about 0.2 mm. The Faro scanner was also better in angle measurements and the angle measurement accuracy was about 0.5°. Conclusion: The three facial scanners all have good reliability in facial measurements, and their actual measurement accuracy for patients needs further research.

Key words: Imaging, three-dimensional, Face, Dimensional measurement accuracy, Laser scanning

[1] Da-wei WANG,Hua-dong WANG,Li LI,Xin YIN,Wei HUANG,Ji-dong GUO,Ya-feng YANG,Yi-hao LIU,Yang ZHENG. Efficacy analysis of autologous facet joint bone block in lumbar interbody fusion of osteoporosis patients [J]. Journal of Peking University (Health Sciences), 2023, 55(5): 899-909.
[2] Qian DING,Wen-jin LI,Feng-bo SUN,Jing-hua GU,Yuan-hua LIN,Lei ZHANG. Effects of surface treatment on the phase and fracture strength of yttria- and magnesia-stabilized zirconia implants [J]. Journal of Peking University (Health Sciences), 2023, 55(4): 721-728.
[3] Ao-nan WEN,Wei LIU,Da-wei LIU,Yu-jia ZHU,Ning XIAO,Yong WANG,Yi-jiao ZHAO. Preliminary evaluation of the trueness of 5 chairside 3D facial scanning techniques [J]. Journal of Peking University (Health Sciences), 2023, 55(2): 343-350.
[4] Wei-wei LI,Hu CHEN,Yong WANG,Yu-chun SUN. Research on friction and wear behaviors of silicon-lithium spray coating on zirconia ceramics [J]. Journal of Peking University (Health Sciences), 2023, 55(1): 94-100.
[5] Hao-zhe YU,Wei-zhen ZENG,Wen-yu WU,Zhong-qiang YAO,Yun FENG. Evaluation of ocular surface status and function in primary Sjögren's syndrome with hypothyroidism [J]. Journal of Peking University (Health Sciences), 2022, 54(4): 705-711.
[6] Hao LUO,Fu-cong TIAN,Xiao-yan WANG. Surface roughness, gloss and sequential polishing times of various chairside computer aided design/manufacturing restorative materials [J]. Journal of Peking University (Health Sciences), 2022, 54(3): 565-571.
[7] WANG Zheng,DING Qian,GAO Yuan,MA Quan-quan,ZHANG Lei,GE Xi-yuan,SUN Yu-chun,XIE Qiu-fei. Effect of porous zirconia ceramics on proliferation and differentiation of osteoblasts [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 31-39.
[8] LI Si-yu,DUAN Xue-fei,CAO Ye. Evaluation of the effect of using ultrasonic instruments to improve the shoulder of the preparations [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 88-94.
[9] Ren-tao TANG,Xin-hai LI,Jiang-li YU,Lin FENG,Xue-jun GAO. Evaluation of microtensile bond strength between resin composite and glass ceramic [J]. Journal of Peking University (Health Sciences), 2020, 52(4): 755-761.
[10] Jing-ying HU,Li LI,Qian-mei ZHOU,Rui-yu DING,Ran SHANG,Wei BAI. Influence of different mixing pads on physical and mechanical properties of glass ionomer cement [J]. Journal of Peking University(Health Sciences), 2019, 51(5): 964-967.
[11] Chao WU,Zhen-yu WANG,Guo-zhong LIN,Tao YU,Bin LIU,Yu SI,Yi-bo ZHANG,Yuan-chao LI. Biomechanical changes of sheep cervical spine after unilateral hemilaminectomy and different degrees of facetectomy [J]. Journal of Peking University(Health Sciences), 2019, 51(4): 728-732.
[12] JIA Peng-chen, YANG Gang, HU Wen-jie, ZHAO Yi-jiao, LIU Mu-qing. Preliminary study on the accuracy of infrabony root surface area of single-root teeth by periapical films [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 91-97.
[13] ZHANG Hao-yu, JIANG Ting, CHENG Ming-xuan, ZHANG Yu-wei. Wear intensity and surface roughness of microhybrid composite and ceramic occlusal veneers on premolars after the thermocycling and cyclic mechanical loading tests [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 73-77.
[14] LIANG Nai-wen, SHI Lei,HUANG Ying,DENG Xu-liang. Role of different scale structures of titanium implant in the biological behaviors of human umbilical vein endothelial cells [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 43-048.
[15] LI Min, WANG Si-wei, ZHAO Yi-jiao, LIU Yi. A cone-beam computed tomography study on crown-root morphology of maxillary anterior teeth in Class Ⅱ, division 2 malocclusion [J]. Journal of Peking University(Health Sciences), 2016, 48(1): 105-110.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!