Journal of Peking University(Health Sciences) ›› 2015, Vol. 47 ›› Issue (2): 336-339. doi: 10.3969/j.issn.1671-167X.2015.02.029

• Articles • Previous Articles     Next Articles

Application of spark erosion technology in manufacture of implant prosthesis

CUI Hong-yan, DI Ping, LI Jian-hui, LIN Ye△, LIU Rong-rong   

  1. (Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing 100081, China)
  • Online:2015-04-18 Published:2015-04-18

Abstract: Objective: To evaluate the influence of the implant-supported porcelain bridges made from non-precious metals using spark erosion techniques, and to discuss the feasibility and details of making the implant restoration by spark erosion technique. Methods: The study included 12 patients (9 males and 3 females) with 92 units implant-supported non-precious porcelain bridge from Sep. 2011 to Feb. 2013. All the patients received implant treatment in Department of Oral Implantology, Peking University School and Hospital of Stomatology. The total of 52 implants, were from Nobel Biocare implant system, Camlog implant system and Ankylos implant system. The implant analogs were connected in sequence with a copper wire to guarantee conductivity. The implant electrodes represented one electrode and the superstructure the other. During spark-erosion machining, the cast holding the implant electrodes and the prosthetic framework were moved toward one another, causing an electrical erosion of the protruding elements. Results: After the spark-erosion machining, the minimum gap between the framework and abutment was 0.21 mm, which was two units bridge. The maximum was 2.59 mm, which was 11 units bridge with 6 implants. The average gap was 0.68 mm. After the spark-erosion machining, the bridge fitted well with the passive position stability. Conclusion: The method of making implantsupported non-precious porcelain bridge reduces costs on patients. Spark erosion has the potential to provide implant framework with an excellent fit. The patients are satisfied with the clinical results.

Key words: Dental implants, Dental prosthesis, Spark erosion

CLC Number: 

  • R783

[1] Yulan WANG, Hao ZENG, Yufeng ZHANG. Current situation and exploration of clinical transformation of plasmatrix in oral implantology [J]. Journal of Peking University (Health Sciences), 2025, 57(5): 836-840.
[2] Ziyang YU, Houzuo GUO, Xi JIANG, Weihua HAN, Ye LIN. Imaging study of osteogenesis in maxillary sinus segment of zygomatic implants [J]. Journal of Peking University (Health Sciences), 2025, 57(5): 967-974.
[3] Fangru LIN, Zhihui TANG. Correlation analysis of peri-implant health after single-tooth dental implant [J]. Journal of Peking University (Health Sciences), 2025, 57(2): 347-353.
[4] Juan WANG, Lixin QIU, Huajie YU. Influence of emergence profile designs on the peri-implant tissue in the mandibular molar: A randomized controlled trial [J]. Journal of Peking University (Health Sciences), 2025, 57(1): 65-72.
[5] Yifan KANG, Yanjun GE, Xiaoming LV, Shang XIE, Xiaofeng SHAN, Zhigang CAI. One-stage mandibular reconstruction combining iliac flap with immediate implant-based denture [J]. Journal of Peking University (Health Sciences), 2025, 57(1): 78-84.
[6] Congwei WANG,Min GAO,Yao YU,Wenbo ZHANG,Xin PENG. Clinical analysis of denture rehabilitation after mandibular fibula free-flap reconstruction [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 66-73.
[7] Sui LI,Wenjie MA,Shimin WANG,Qian DING,Yao SUN,Lei ZHANG. Trueness of different digital design methods for incisal guidance of maxillary anterior implant-supported single crowns [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 81-87.
[8] Qian DING,Wen-jin LI,Feng-bo SUN,Jing-hua GU,Yuan-hua LIN,Lei ZHANG. Effects of surface treatment on the phase and fracture strength of yttria- and magnesia-stabilized zirconia implants [J]. Journal of Peking University (Health Sciences), 2023, 55(4): 721-728.
[9] Meng-en OU,Yun DING,Wei-feng TANG,Yong-sheng ZHOU. Three-dimensional finite element analysis of cement flow in abutment margin-crown platform switching [J]. Journal of Peking University (Health Sciences), 2023, 55(3): 548-552.
[10] Fei SUN,Jian LIU,Si-qi LI,Yi-ping WEI,Wen-jie HU,Cui WANG. Profiles and differences of submucosal microbial in peri-implantitis and health implants: A cross-sectional study [J]. Journal of Peking University (Health Sciences), 2023, 55(1): 30-37.
[11] MA Ke-nan,CHEN Hu,SHEN Yan-ru,ZHOU Yong-sheng,WANG Yong,SUN Yu-chun. Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 105-112.
[12] LI Yi,YU Hua-jie,QIU Li-xin. Clinical classification and treatment decision of implant fracture [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 126-133.
[13] WANG Juan,YU Hua-jie,SUN Jing-de,QIU Li-xin. Application evaluation of prefabricated rigid connecting bar in implants immediate impression preparation of edentulous jaw [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 187-192.
[14] SUN Yu-chun,GUO Yu-qing,CHEN Hu,DENG Ke-hui,LI Wei-wei. Independent innovation research, development and transformation of precise bionic repair technology for oral prosthesis [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 7-12.
[15] Feng LIANG,Min-jie WU,Li-dong ZOU. Clinical observation of the curative effect after 5-year follow-up of single tooth implant-supported restorations in the posterior region [J]. Journal of Peking University (Health Sciences), 2021, 53(5): 970-976.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!