论著

三种数字化分析算法测量咬合接触分布及面积的对比研究

  • 萧宁 ,
  • 孙玉春 ,
  • 赵一姣 ,
  • 王勇
展开
  • 北京大学口腔医学院·口腔医院,口腔医学数字化研究中心,口腔修复教研室 国家口腔疾病临床医学研究中心口腔数字化医疗技术和材料国家工程实验室 口腔数字医学北京市重点实验室,北京 100081

收稿日期: 2019-10-10

  网络出版日期: 2020-02-20

基金资助

国家自然科学基金面上项目(81870815);国家重点研发计划课题(2018YFB1106903);宁夏回族自治区重点研发计划重点项目课题(2018BEG02012)

Preliminary study on three digital analysis methods for analyzing the distribution and area of occlusal contacts

  • Ning XIAO ,
  • Yu-chun SUN ,
  • Yi-jiao ZHAO ,
  • Yong WANG
Expand
  • Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China

Received date: 2019-10-10

  Online published: 2020-02-20

Supported by

Supported by the General Program of National Natural Science Foundation of China(81870815);the National Key R&D Program of China(2018YFB1106903);the Key R&D Program of Ningxia Hui Autonomous Region(2018BEG02012)

摘要

目的:研究三种数字化分析算法测量石膏牙颌模型三维咬合接触分布及面积的检测效果,并与传统咬合分析方法进行比较,探究各数字化分析算法的特点和应用。方法:选取一副正常受试者的上、下颌石膏牙颌模型,使用3shape E4牙颌模型三维扫描仪进行数字化扫描得到数字模型,在三维测量分析软件Geomagic Studio 2013及Geomagic Qualify 2013中采用“三维偏差色阶图法”、“点云统计分析法”和“虚拟咬合纸法”三种数字化分析算法获得相应的三维咬合接触分布及面积,同时使用牙合记录硅橡胶法及咬合纸扫描法两种传统咬合分析方法获得咬合接触分布和面积。各方法的咬合检测阈值为100 μm,量化评价各数字化分析算法与传统咬合分析方法的检测结果。结果:上述五种方法所得的全牙列咬合接触分布的定性评价结果基本一致,三维偏差色阶图法、点云统计分析法、虚拟咬合纸法、牙合记录硅橡胶法和咬合纸扫描法所得到的总咬合接触面积分别为133.10 mm 2、142.08 mm 2、128.95 mm 2、163.31 mm 2、100.55 mm 2。三种数字化分析算法间的检测结果差异性不大,数字化方法与传统方法检测的总咬合接触面积有一定差异。结论:三种数字化分析算法均可提供较为可靠、准确的牙颌模型咬合接触分布及面积量化分析结果,可为口腔临床修复体数字化设计制作及咬合分析提供参考。

本文引用格式

萧宁 , 孙玉春 , 赵一姣 , 王勇 . 三种数字化分析算法测量咬合接触分布及面积的对比研究[J]. 北京大学学报(医学版), 2020 , 52(1) : 144 -151 . DOI: 10.19723/j.issn.1671-167X.2020.01.023

Abstract

Objective: To analyze the distribution and area of occlusal contacts of clinical dental model using three kinds of digital analysis methods, to compare the results of these methods and traditional occlusal analysis method, and to further analyze the characteristics of each digital analysis method. Methods: A set of plaster models of normal subjects was selected. The models were scanned by lab scanner 3shape E4 and the files were exported in a stereolithography file format. In 3D analysis software Geomagic Studio 2013 and Geomagic Qualify 2013, the corresponding results of 3D occlusal contact distribution and occlusal contact area were obtained through three digital analysis methods: “3D color difference map method”, “point cloud analysis method”, and “virtual articulating paper method”. The occlusal contact distribution and occlusal contact area were also obtained by two traditional occlusal analysis methods: “silicone interocclusal recording material method” and “scanned articulating paper mark method”. A threshold of 100 μm was used to analyze the occlusal contacts and 100 μm was also the thickness of arti-culating paper used in this study. The results of these five different occlusal analysis methods were evaluated qualitatively and quantitatively. Results: The results of 3D occlusal contact distribution obtained by the above five methods were basically consistent. The total occlusal contact area obtained by 3D color difference map method, point cloud analysis method, virtual articulating paper method, silicone interocclusal recording material method and scanned articulating paper mark method were 133.10 mm 2, 142.08 mm 2, 128.95 mm 2, 163.31 mm 2, and 100.55 mm 2 respectively. There was little difference between the results of three digital analysis methods. The results of occlusal contact area obtained by the digital methods and the traditional methods were different. Conclusion: The three digital analysis methods can provide reliable and accurate analysis results of occlusal contact distribution and occlusal contact area of dental model. The results obtained by these methods can serve as references for the digital occlusal surface design of dental prosthesis and clinical occlusal analysis.

参考文献

[1] 马斐斐, 胡秀莲, 林野 . 口腔种植修复与咬合[J]. 实用口腔医学杂志, 2013,29(1):121-123.
[2] Foz AM, Artese HP, Horliana AC , et al. Occlusal adjustment associated with periodontal therapy: A systematic review[J]. J Dent, 2012,40(12):1025-1035.
[3] 曾艳, 王嘉德 . 牙体牙髓病临床问题解析Ⅱ. 牙齿的慢性损伤性疾病[J]. 中华口腔医学杂志, 2009,44(7):441-443.
[4] 谢秋菲 . 牙体解剖与口腔生理学 [M]. 北京: 北京大学医学出版社, 2013.
[5] Abduo J, Bennamoun M, Tennant M , et al. Effect of prosthodontic planning on intercuspal occlusal contacts: Comparison of digital and conventional planning[J]. Comput Biol Med, 2015,60:143-150.
[6] Moreno-Hay I, Okeson JP . Does altering the occlusal vertical dimension produce temporomandibular disorders? A literature review[J]. J Oral Rehabil, 2015,42(11):875-882.
[7] 韩科, 张豪 . 牙合学理论与临床实践 [M]. 北京: 人民军医出版社, 2014.
[8] 宋倩, 王辉, 冯春雷 , 等. 咬合纸指导调牙合可靠性的定量研究[J]. 牙体牙髓牙周病学杂志, 2016,26(2):86-90.
[9] Koos B, Godt A, Schille C , et al. Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch[J]. J Orofac Orthop, 2010,71(6):403-410.
[10] Forrester SE, Presswood RG, Toy AC , et al. Occlusal measurement method can affect SEMG activity during occlusion[J]. J Oral Rehabil, 2011,38(9):655-660.
[11] 赵一姣, 王勇, 吕培军 . 一种基于数字化牙颌模型的三维咬合分析方法[J]. 北京大学学报(医学版), 2008,40(1):109-111.
[12] Gintaute A, Keeling AJ, Osnes CA , et al. Precision of maxillo-mandibular registration with intraoral scanners in vitro [J]. J Prosthodont Res, 2019, pii: S1883- 1958(19) 30145-8. doi: 10.1016/j.jpor.2019.05.006.[Epub ahead of print].
[13] Lee H, Cha J, Chun YS , et al. Comparison of the occlusal contact area of virtual models and actual models: a comparative in vitro study on Class Ⅰ and Class Ⅱ malocclusion models[J]. Bmc Oral Health, 2018,18(1):109.
[14] 陈磊, 张豪, 冯海兰 , 等. 正常受试者单侧咀嚼运动中的牙合接触模式[J]. 北京大学学报(医学版), 2009,41(1):90-94.
[15] Abduo J . Geometrical effects of conventional and digital prosthodontic planning wax-ups on lateral occlusal contact number, contact area, and steepness[J]. J Oral Sci, 2017,59(3):431-438.
[16] Iwase Y, Saitoh I, Okamoto A , et al. Do occlusal contact areas of maximum closing position during gum chewing and intercuspal position coincide?[J]. Arch Oral Biol, 2011,56(12):1616-1623.
[17] Schelb E, Kaiser DA, Brukl CE . Thickness and marking characteristics of occlusal registration strips[J]. J Prosthet Dent, 1985,54(1):122-126.
[18] Cohen-Levy J, Cohen N . Computerized analysis of occlusal contacts after lingual orthodontic treatment in adults[J]. Int Orthod, 2011,9(4):410-431.
[19] Qadeer S, Kerstein R, Kim RJ , et al. Relationship between arti-culation paper mark size and percentage of force measured with compu-terized occlusal analysis[J]. J Adv Prosthodont, 2012,4(1):7-12.
[20] Kerstein RB . Articulating paper mark misconceptions and compu-terized occlusal analysis technology: A clinical brief[J]. Dent Implantol Update, 2008,19(6):41-46.
[21] Toledo MF, Jóias RP, Marques-Iasi YS , et al. Thickness and marking quality of different occlusal contact registration strips[J]. J Appl Oral Sci, 2014,22(6):516-521.
[22] Malta Barbosa J, Urtula AB, Hirata R , et al. Thickness evaluation of articulating papers and foils[J]. J Esthet Restor Dent, 2018,30(1):70-72.
[23] Sara?o?lu A, Ozpinar B . In vivo and in vitro evaluation of occlusal indicator sensitivity[J]. J Prosthet Dent, 2002,88(5):522-526.
[24] Matsui Y, Ohno K, Michi K , et al. A computerized method for evaluating balance of occlusal load[J]. J Oral Rehabil, 1996,23(8):530-535.
[25] Imamura Y, Sato Y, Kitagawa N , et al. Influence of occlusal loading force on occlusal contacts in natural dentition[J]. J Prosthodont Res, 2015,59(2):113-120.
[26] Augusti D, Augusti G, Re D , et al. Effect of different dental articulating papers on SEMG activity during maximum clenching[J]. J Electromyogr Kinesiol, 2015,25(4):612-618.
[27] Sharma A, Rahul GR, Poduval ST , et al. History of materials used for recording static and dynamic occlusal contact marks: a literature review[J]. J Clin Exp Dent, 2013,5(1):e48-e53.
[28] 易新竹 . 牙合学[M]. 北京: 人民卫生出版社, 2012.
[29] Makino E, Nomura M, Motegi E , et al. Effect of orthodontic treatment on occlusal condition and masticatory function[J]. Bull Tokyo Dent Coll, 2014,55(4):185-197.
[30] Horie T, Kanazawa M, Komagamine Y , et al. Association between near occlusal contact areas and mixing ability[J]. J Oral Rehabil, 2014,41(11):829-835.
[31] 刘洋 . 调牙合——临床实用技术图解 [M]. 南京: 江苏凤凰科学技术出版社, 2018.
[32] Brizuela-Velasco A, álvarez-Arenal á, Ellakuria-Echevarria J , et al. Influence of articulating paper thickness on occlusal contacts registration: A preliminary report[J]. Int J Prosthodont, 2015,28(4):360-362.
[33] Komiyama O, Obara R, Iida T , et al. Comparison of direct and indirect occlusal contact examinations with different clenching intensities[J]. J Oral Rehabil, 2015,42(3):185-191.
[34] 程明轩, 姜婷, 孙玉春 , 等. 比较口内扫描和模型扫描对数字化牙列模型咬合定量分析的影响[J]. 北京大学学报(医学版), 2018,50(1):136-140.
[35] Ayuso-Montero R, Mariano-Hernandez Y, Khoury-Ribas L , et al. Reliability and validity of T-scan and 3D intraoral scanning for measuring the occlusal contact area[J]. J Prosthodont, 2019. doi: 10.1111/jopr.13096.
[36] Gupta S, Tarannum F, Gupta NK , et al. Effect of head posture on tooth contacts in dentate and complete denture wearers using computerized occlusal analysis system[J]. J Indian Prosthodont Soc, 2017,17(3):250-254.
[37] Nishimori H, Iida T, Kamiyama H , et al. Comparing the occlusal contact area of individual teeth during low-level clenching[J]. J Oral Sci, 2017,59(3):337-342.
文章导航

/