Journal of Peking University (Health Sciences) ›› 2020, Vol. 52 ›› Issue (2): 368-372. doi: 10.19723/j.issn.1671-167X.2020.02.027

Previous Articles     Next Articles

A novel tray for recording maxillomandibular relationship of edentulous patients based on dimensional surveying of complete dentures

Yang LIU,Jin-ru HU,Yi-jiao ZHAO,Yong WANG,Yu-chun SUN,Shao-xia PAN,Hai-lan FENG()   

  1. Department of Prosthodontics, Center for Digital Dentistry, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
  • Received:2019-10-10 Online:2020-04-18 Published:2020-04-18
  • Contact: Hai-lan FENG E-mail:kqfenghl@bjmu.edu.cn

RICH HTML

  

Abstract:

Objective: To measure the dimensional data of complete dentures and to design a novel tray for recording maxillomandibular relationship of edentulous patients.Methods: For the measurement, 100 pairs of complete dentures from the clinic were surveyed for the following parameters: a1, the distance between the middle fossa of the upper left and right first molars; a2, the anterior-posterior distance between the middle fossa of the upper first molars and the incisal edge; a3, the width of the upper denture; a4, the anterior-posterior length of the upper denture; a51, the height from the mesio-lingual cusp of the right upper first molar to the saddle surface; a52, the height from the central fossa of the right lower first molar to the saddle surface; a6, the height from the notch of the upper lip frenulum to the upper central incisor edge; a7, the least thickness of the labial saddle base in the upper central incisor region. Based on the data, the trays with different sizes were designed and fabricated, and the key parameters were: b1, the distance between the foramina of screw posts, b2, the anterior-posterior distance between the foramina of the screw posts and the incisal edge; b3, the width of the tray; b4, the anterior-posterior length of the tray; b51, the height of the posterior platform with the screw nut; b52, the height of the screw post; b6, the height of the anterior tray handle; b7, the thickness of the anterior tray handle.Results: The minimum, average and maximum data for each parameter were (in millimeter): a1: 37.1, 44.5, and 59.6; a2: 22.6, 29.0, and 38.1; a3: 48.5, 58.2, and 76.6; a4: 37.4, 50.8, and 61.0; a51: 5.6, 9.5, and 14.7; a52: 3.8, 9.9, and 18.8; a6: 8.9, 16.6, and 24.7; a7: 1.2, 2.8, and 5.9. Based on the data, the trays in small, medium and large sizes were designed and fabricated. In clinical application, the putty silicone rubber impression material was used to reline the tray, meanwhile the posterior platform and anterior tray handle were set as the occlusal plane, then the screw posts were added and adjusted till the proper vertical dimension, after that, the putty silicone rubber impression material was added around the screw posts to record the horizontal maxillomandibular relationship, finally, the anterior surface of the tray handle was used to record the midline of the face and lower edge of the upper lip at rest and with smile.Conclusion: The dimensional data offered reference for the analysis of restoration space in edentulous patients. The tray designed and fabricated in this study may serve as a new tool for recording the maxillomandibular relationship.

Key words: Jaw, edentulous, Denture, complete, Maxillomandibular relationship, Prosthodontics

CLC Number: 

  • R783.6

Figure 1

The illustration of measured parameters of complete dentures and the related counterpart of tray a1, the distance between the middle fossa of the upper left and right first molars; a2, the anterior-posterior distance between the middle fossa of the upper first molars and the incisal edge; a3, the width of upper denture; a4, the anterior-posterior length of upper denture; a51, the height from the mesio-lingual cusp of right upper first molar to saddle surface; a52, the height from the central fossa of right lower first molar to saddle surface; a6, the height from the notch of upper lip frenulum to the upper central incisor edge; a7, the least thickness of labial saddle base in the upper central incisor region. b1, the distance between the foramina of screw posts; b2, the anterior-posterior distance between the foramina of screw posts and the incisal edge; b3, the width of tray; b4, the anterior-posterior length of tray; b51, the height of the posterior platform with screw nut; b52, the height of the screw post; b6, the height of the anterior tray handle; b7, the thickness of the anterior tray handle."

Figure 2

The measured data of complete denturesFor the definition of a1-a7, please refer to the figure legend of figure 1."

Figure 3

The application of the tray A, after relining with putty silicone rubber, the occlusal plane was determined; B, the screw posts were adjusted till the proper vertical dimension; C, the silicone rubber was then added to record the maxillomandibular relationship; D, the rigid stand bars of screw posts may present as bumps outside the silicone rubber, which should be trimmed before locating the record between the upper and lower working models (yellow arrows)."

[1] 王兴 . 第四次全国口腔健康流行病学调查报告 [M]. 北京: 人民卫生出版社, 2018.
[2] Kassebaum NJ, Bernabé E, Dahiya M , et al. Global burden of severe tooth loss: A systematic review and meta-analysis[J]. J Dent Res, 2014,93(7 Suppl):20S-28S.
[3] 张书宇, 董华 . 上海市嘉定区65~74岁老年人群牙列缺损及修复现状调查[J]. 上海口腔医学, 2018,27(5):522-525.
[4] 冯海兰, 徐军 . 口腔修复学[M]. 第2版. 北京: 北京大学医学出版社, 2013.
[5] 徐军 . 总义齿与可摘局部义齿的设计[M].中国大百科全书出版社, 2005.
[6] Rahn AO, Ivanhoe JR, Plummer KD. 全口义齿教科书[M].冯海兰,译. 第6版. 北京:人民卫生出版社, 2011.
[7] 阿部二郎 ,小久保京子,佐藤幸司.下颌吸附性义齿和BPS临床指南[M]. 骆小平译. 北京:, 人民军医出版社, 2014.
[8] Bhargav A, Sanjairaj V, Rosa V , et al. Applications of additive manufacturing in dentistry: A review[J]. J Biomed Mater Res B Appl Biomater, 2018,106(5):2058-2064.
[9] Al-Zarea BK, Sughaireen MG . Comparative analysis of dimen-sional precision of different silicone impression materials[J]. J Con-temp Dent Pract, 2011,12(3):208-215.
[10] Hayakawa I. 全口义齿原理与实践: 塑造心中的义齿形象[M]. 张玉梅,程静涛, 译. 北京:人民军医出版社, 2005.
[11] 徐军 . 总义齿学续[M]. 北京: 人民卫生出版社, 2015.
[12] 佐藤幸司, 石川功和, 生田龙平 . 初学者的总义齿制作方法[M]. 包扬,译. 沈阳: 辽宁科学技术出版社, 2016.
[13] 吴国锋, 张玉梅 . 全口义齿临床修复规范[M]. 北京: 人民军医出版社, 2012.
[14] 王子轩, 孙玉春, 周永胜 . 数字化全口义齿的研究和应用进展[J]. 口腔颌面修复学杂志, 2017,18(5):291-295.
[1] Xinxin ZHAN,Lulu CAO,Dong XIANG,Hao TANG,Dandan XIA,Hong LIN. Effect of printing orientation on physical and mechanical properties of 3D printing prosthodontic base resin materials [J]. Journal of Peking University (Health Sciences), 2024, 56(2): 345-351.
[2] Jiayun DONG,Xuefen LI,Ruifang LU,Wenjie HU,Huanxin MENG. Histopathological characteristics of peri-implant soft tissue in reconstructed jaws with vascularized bone flaps [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 25-31.
[3] Ying ZHOU,Ning ZHAO,Hongyuan HUANG,Qingxiang LI,Chuanbin GUO,Yuxing GUO. Application of double-layer soft tissue suture closure technique in the surgical treatment of patients with mandible medication-related osteonecrosis of the jaw of early and medium stages [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 51-56.
[4] Tuan-feng ZHOU,Xue YANG,Rui-jie WANG,Ming-xuan CHENG,Hua ZHANG,Jin-qi WEI. A clinical application study of digital manufacturing simple intraoral Gothic arch-tracing device in determining the centric relation of complete dentures [J]. Journal of Peking University (Health Sciences), 2023, 55(1): 101-107.
[5] Yu-xing GUO,Jian-yun ZHANG,Dian-can WANG,Chuan-bin GUO. Analysis of pathological characteristics of medication-related osteonecrosis of the jaw and discussion of clinical treatment strategies based on the pathological analysis results [J]. Journal of Peking University (Health Sciences), 2022, 54(6): 1190-1195.
[6] WANG Juan,YU Hua-jie,SUN Jing-de,QIU Li-xin. Application evaluation of prefabricated rigid connecting bar in implants immediate impression preparation of edentulous jaw [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 187-192.
[7] SUN Yu-chun,GUO Yu-qing,CHEN Hu,DENG Ke-hui,LI Wei-wei. Independent innovation research, development and transformation of precise bionic repair technology for oral prosthesis [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 7-12.
[8] YOON Jung-min,WANG Zi-xuan,CHAN Chon-kai,SUN Yu-chun,LIU Yun-song,YE Hong-qiang,ZHOU Yong-sheng. Evaluation of methods for fitness of removable partial denture [J]. Journal of Peking University (Health Sciences), 2021, 53(2): 406-412.
[9] XU Xiao-xiang,CAO Ye,ZHAO Yi-jiao,JIA Lu,XIE Qiu-fei. In vitro evaluation of the application of digital individual tooth tray in the impression making of mandibular full-arch crown abutments [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 54-61.
[10] FANG Shuo-bo,YANG Guang-ju,KANG Yan-feng,SUN Yu-chun,XIE Qiu-fei. Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 76-82.
[11] Ke-yi HAO,Jia LUO,Ping DI,Hou-zuo GUO,Hui-dan SHEN,Yan-ping LIU,Yu ZHANG,Ye LIN. Validation of the digital integration technology for evaluating the nasolabial morphology variation after the cross-arch fixed restoration of maxillary implant-supported prostheses [J]. Journal of Peking University (Health Sciences), 2020, 52(5): 924-930.
[12] Ling WEI,Dong ZOU,Hu CHEN,Shao-xia PAN,Yu-chun SUN,Yong-sheng ZHOU. Evaluation of clinical efficacy of a kind of digital complete denture [J]. Journal of Peking University (Health Sciences), 2020, 52(4): 762-770.
[13] Yu-chun SUN,Yong WANG,Ke-hui DENG,Hu CHEN,Wei-wei LI,Yi-jiao ZHAO,Shao-xia PAN,Hong-qiang YE,Yong-sheng ZHOU. Independent innovation research of functionally suitable denture digital system [J]. Journal of Peking University (Health Sciences), 2020, 52(2): 390-394.
[14] Lang YOU,Ke-hui DENG,Wei-wei LI,Yi-jiao ZHAO,Yu-chun SUN,Yong-sheng ZHOU. Visual sensitivity threshold of lateral view of nasolabial Angle changes in edentulous jaw patients [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 107-112.
[15] Yue CAO,Jun-kai CHEN,Ke-hui DENG,Yong WANG,Yu-chun SUN,Yi-jiao ZHAO. Accuracy of three intraoral scans for primary impressions of edentulous jaws [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 129-137.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!