Journal of Peking University(Health Sciences) ›› 2015, Vol. 47 ›› Issue (2): 263-268. doi: 10.3969/j.issn.1671-167X.2015.02.014

• Articles • Previous Articles     Next Articles

Radiographic analysis of treatment of inter-trochanteric fractures using proximal femoral nails

ZHAO Jing-xin, SU Xiu-yun, ZHAO Zhe, ZHANG Li-cheng, ZHANG Li-hai, TANG Pei-fu△   

  1. (Department of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853)
  • Online:2015-04-18 Published:2015-04-18

Abstract: Objective: To establish a reliable approach for measuring proximal femoral 3 dimensional anatomy, and to compare post-operative differences of proximal femoralanatomy in the inter-trochanter fractures with two kinds of antegrade nailings.Methods: Some computer assisted design (CAD) softwares, e.g. Mimics, were used to establish a reliable approach for measuring proximal femoral 3 dimensional (3D) anatomy. Intra-class correlation coefficient (ICC) was used to test the reliability of intra- and inter-observers. The post-operative pelvic CT data of 19 cases of inter-trochanter fracture patients treated with InterTAN nailing and 21 cases of inter-trochanter fracture patients treated with proximal femoral nail anti-rotation (PFNA) were retrospectively analysed and used to measure bilateral proximal femoral anatomical parameters, including 2D and 3D femoral neck-shaft (NS) angle and femoral neck anteversion (NA) angle, and 2D and 3D anteversion angles of the intramedullary (IM) nailings. ICC was used to test the consistency of the NA angles in the different groups, and the paired student T-test was used to test the differences of the paired quantitative data. Results: The established measurement method hasdexcellent consistency within the intra- and inter-observers, with all the ICCs higher than 0.9. The paired student T-test showed no significant difference between the post-operative bilateral 2D or 3D NA angles. The ICCs results showed that there were no consistency between the post-operative bilateral 2D or 3D NA angles (P values were 0.099 and 0.055, respectively), but the excellent consistency between the 2D injured side NA angle and 2D IM nailing’s NA angle, or between the 3D injured side NA angle and 3D IM nailing’s NA angle (the ICCs were 0.81 and 0.8, respectively, P values < 0.001). In PFNA group, 57% of the differences between the 2D post-operative injured side’s and intact side’s NA angles were higher than 15°, which was more than 15.78% in InterTAN group. The paired student T-test showed no significant difference between the post-operative injured side’s 2D or 3D NS angles and the intact side’s respective 2D or 3D angles in PFNA group (P values were 0.925 and 0.367, respectively), but in InterTAN group, the post-operative injured side’s 2D or 3D NS angles were significantly smaller than the intact side’s respective angles (P values were 0.033 and 0.009, respectively). Conclusion: By analyzing and comparing bilateral proximal femoral anatomical parameters after two kinds of IM nailings procedures, the differences between the bilateral post-operative NA angles in PFNA group were significantly larger than those in InterTAN group. There was significant correlation between the NA angles of the injured sides and NA angles of IM nailings in both the groups.

Key words: Femoral fractures, Fracture fixation, intramedullary, Bone nails, Computer-aided design

CLC Number: 

  • R683.42
[1] LI Yi,WONG Lai U,LIU Xiao-qiang,ZHOU Ti,LYU Ji-zhe,TAN Jian-guo. Marginal features of CAD/CAM laminate veneers with different materials and thicknesses [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 140-145.
[2] QIU Shu-ting,ZHU Yu-jia,WANG Shi-min,WANG Fei-long,YE Hong-qiang,ZHAO Yi-jiao,LIU Yun-song,WANG Yong,ZHOU Yong-sheng. Preliminary clinical application verification of complete digital workflow of design lips symmetry reference plane based on posed smile [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 193-199.
[3] YUE Zhao-guo,ZHANG Hai-dong,YANG Jing-wen,HOU Jian-xia. Comparison of residual cement between CAD/CAM customized abutments and stock abutments via digital measurement in vitro [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 69-75.
[4] XU Xiao-xiang,CAO Ye,ZHAO Yi-jiao,JIA Lu,XIE Qiu-fei. In vitro evaluation of the application of digital individual tooth tray in the impression making of mandibular full-arch crown abutments [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 54-61.
[5] LI Zheng,LIU Yu-shu,WANG Shi-min,ZHANG Rui,JIA Lu,YE Hong-qiang,HU Wen-jie,ZHAO Wen-yan,LIU Yun-song,ZHOU Yong-sheng. Application of biocopy function of temporary crown occlusal morphology in patients with severe attrition [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 62-68.
[6] FANG Shuo-bo,YANG Guang-ju,KANG Yan-feng,SUN Yu-chun,XIE Qiu-fei. Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 76-82.
[7] Lang YOU,Ke-hui DENG,Wei-wei LI,Yi-jiao ZHAO,Yu-chun SUN,Yong-sheng ZHOU. Visual sensitivity threshold of lateral view of nasolabial Angle changes in edentulous jaw patients [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 107-112.
[8] Yun-peng CUI,Chuan MI,Bing WANG,Yuan-xing PAN,Yun-fei LIN,Xue-dong SHI. Perioperative clinical characteristics of patients with pathological fracture of proximal femur [J]. Journal of Peking University(Health Sciences), 2019, 51(5): 875-880.
[9] Shuo CHEN,Yang HE,Jin-gang AN,Yi ZHANG. Application of computer-aided virtual mandibular position in the simultaneous treatment of children with temporomandibular joint ankylosis and jaw deformity [J]. Journal of Peking University(Health Sciences), 2019, 51(5): 954-958.
[10] Yi-ran ZHANG,Feng RAO,Wei PI,Pei-xun ZHANG,Bao-guo JIANG. Proximal femoral nails antirotation and dynamic hip screws for fixation of unstable intertrochanteric fractures of femur: A meta-analysis [J]. Journal of Peking University(Health Sciences), 2019, 51(3): 493-500.
[11] Kuan-paul WANG,Hong-qiang YE,Hu CHEN,Yong WANG,Yu-chun SUN,Yong-sheng ZHOU. Establishment and preliminary clinical evaluation of edentulous custom trays designed and fabricated by chair-side CAD and 3D printing systems [J]. Journal of Peking University(Health Sciences), 2019, 51(2): 349-355.
[12] Xin-xin LI,Yu-shu LIU,Yu-chun SUN,Hu CHEN,Hong-qiang YE,Yong-sheng ZHOU. Evaluation of one-piece polyetheretherketone removable partial denture fabricated by computer-aided design and computer-aided manufacturing [J]. Journal of Peking University(Health Sciences), 2019, 51(2): 335-339.
[13] Shi-min WANG,Zheng LI,Guan-bo WANG,Hong-qiang YE,Yun-song LIU,Dai TONG,Wen-hui GAO,Yong-sheng ZHOU. Preliminary clinical application of complete digital workflow of design and manufacturing occlusal splint for sleep bruxism [J]. Journal of Peking University(Health Sciences), 2019, 51(1): 105-110.
[14] PENG Li, WANG Zu-hua, SUN Yu-chun, QU Wei,HAN Yang, LIANG Yu-hong. Computer aided design and three-dimensional printing forapicoectomy guide template [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 905-910.
[15] CHAI Jin-you, LIU Jian-zhang, WANG Bing, QU Jian, SUN Zhen, GAO Wen-hui, GUO Tian-hao, FENG Hai-lan, PAN Shao-xia. Evaluation of the fabrication deviation of a kind of milling digital implant surgical guides#br# [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 892-898.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] Author. English Title Test[J]. Journal of Peking University(Health Sciences), 2010, 42(1): 1 -10 .
[2] . [J]. Journal of Peking University(Health Sciences), 2009, 41(2): 188 -191 .
[3] . [J]. Journal of Peking University(Health Sciences), 2009, 41(3): 376 -379 .
[4] . [J]. Journal of Peking University(Health Sciences), 2009, 41(4): 459 -462 .
[5] . [J]. Journal of Peking University(Health Sciences), 2010, 42(1): 82 -84 .
[6] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 319 -322 .
[7] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 333 -336 .
[8] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 337 -340 .
[9] . [J]. Journal of Peking University(Health Sciences), 2007, 39(3): 225 -328 .
[10] . [J]. Journal of Peking University(Health Sciences), 2007, 39(4): 346 -350 .