Journal of Peking University (Health Sciences) ›› 2023, Vol. 55 ›› Issue (2): 343-350. doi: 10.19723/j.issn.1671-167X.2023.02.021
Previous Articles Next Articles
Ao-nan WEN1,2,Wei LIU3,Da-wei LIU4,Yu-jia ZHU2,Ning XIAO2,Yong WANG1,2,*(),Yi-jiao ZHAO1,2,*()
CLC Number:
1 |
Fink M , Hirschfelder U , Hirschinger V , et al. Assessment of facial soft-tissue profiles based on lateral photographs versus three-dimensional face scans[J]. J Orofac Orthop, 2017, 78 (1): 70- 76.
doi: 10.1007/s00056-016-0055-z |
2 |
Topsakal O , Akbas MI , Smith BS , et al. Evaluating the agreement and reliability of a web-based facial analysis tool for rhinoplasty[J]. Int J Comput Assist Radiol Surg, 2021, 16 (8): 1381- 1391.
doi: 10.1007/s11548-021-02423-z |
3 | Anas IY , Bamgbose BO , Nuhu S . A comparison between 2D and 3D methods of quantifying facial morphology[J]. Heliyon, 2019, 5 (6): e1880. |
4 |
Stebel A , Desmedt D , Bronkhorst E , et al. Rating nasolabial appearance on three-dimensional images in cleft lip and palate: A comparison with standard photographs[J]. Eur J Orthod, 2016, 38 (2): 197- 201.
doi: 10.1093/ejo/cjv024 |
5 |
Krneta B , Primo IJ , Zhurov A , et al. Three-dimensional evaluation of facial morphology in children aged 5-6 years with a class Ⅲ malocclusion[J]. Eur J Orthod, 2014, 36 (2): 133- 139.
doi: 10.1093/ejo/cjs018 |
6 |
Bockey S , Berssenbrügge P , Dirksen D , et al. Computer-aided design of facial prostheses by means of 3D-data acquisition and following symmetry analysis[J]. J Craniomaxillofac Surg, 2018, 46 (8): 1320- 1328.
doi: 10.1016/j.jcms.2018.05.020 |
7 |
Farook TH , Jamayet NB , Abdullah JY , et al. Designing 3D prosthetic templates for maxillofacial defect rehabilitation: A comparative analysis of different virtual workflows[J]. Comput Biol Med, 2020, 118, 103646.
doi: 10.1016/j.compbiomed.2020.103646 |
8 |
Duppe K , Becker M , Schonmeyr B . Evaluation of facial anthropometry using three-dimensional photogrammetry and direct mea-suring techniques[J]. J Craniofac Surg, 2018, 29 (5): 1245- 1251.
doi: 10.1097/SCS.0000000000004580 |
9 |
van der Meer WJ , Dijkstra PU , Visser A , et al. Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner[J]. Br J Oral Maxillofac Surg, 2014, 52 (10): 922- 927.
doi: 10.1016/j.bjoms.2014.08.019 |
10 |
Andrade LM , Rodrigues da Silva AMB , Magri LV , et al. Repeatability study of angular and linear measurements on facial morpho-logy analysis by means of stereophotogrammetry[J]. J Craniofac Surg, 2017, 28 (4): 1107- 1111.
doi: 10.1097/SCS.0000000000003554 |
11 | Zhao Y , Xiong Y , Wang Y . Three-dimensional accuracy of facial scan for facial deformities in clinics: A new evaluation method for facial scanner accuracy[J]. PLoS One, 2017, 12 (1): e169402. |
12 | Gaber A, Faher MF, Waned MA. Automated grading of facial paralysis using the Kinect v2: A proof of concept study: International Conference on Virtual Rehabilitation (ICVR)[C]. Valencia, Spain: IEEE, 2015: 258-264. |
13 |
Sidequersky FV , Verze L , Mapelli A , et al. Quantification of facial movements by optical instruments: Surface laser scanning and optoelectronic three-dimensional motion analyzer[J]. J Craniofac Surg, 2014, 25 (1): e65- e70.
doi: 10.1097/SCS.0000000000000379 |
14 | Gaber A , Taher MF , Wahed MA . Quantifying facial paralysis using the Kinect v2[J]. Annu Int Conf IEEE Eng Med Biol Soc, 2015, 2015, 2497- 2501. |
15 |
Knoops PG , Beaumont CA , Borghi A , et al. Comparison of three-dimensional scanner systems for craniomaxillofacial imaging[J]. J Plast Reconstr Aesthet Surg, 2017, 70 (4): 441- 449.
doi: 10.1016/j.bjps.2016.12.015 |
16 |
Modabber A , Peters F , Kniha K , et al. Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning[J]. J Craniomaxillofac Surg, 2016, 44 (10): 1719- 1724.
doi: 10.1016/j.jcms.2016.08.008 |
17 |
Ahn H , Chang Y , Kim K , et al. Measurement of three-dimensional perioral soft tissue changes in dentoalveolar protrusion patients after orthodontic treatment using a structured light scanner[J]. Angle Orthod, 2014, 84 (5): 795- 802.
doi: 10.2319/112913-877.1 |
18 |
Dindaroǧlu F , Kutlu P , Duran GS , et al. Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry[J]. Angle Orthod, 2016, 86 (3): 487- 494.
doi: 10.2319/041415-244.1 |
19 | 熊玉雪, 杨慧芳, 赵一姣, 等. 两种评价面部三维表面数据不对称度方法的比较[J]. 北京大学学报(医学版), 2015, 47 (2): 340- 343. |
20 |
Zeng W , Chen G , Ju R , et al. The combined application of database and three-dimensional image registration technology in the restoration of total nose defect[J]. J Craniofac Surg, 2018, 29 (5): e484- e487.
doi: 10.1097/SCS.0000000000004500 |
21 | 赵一姣, 熊玉雪, 杨慧芳, 等. 2种三维颜面部扫描仪测量精度的定量评价[J]. 实用口腔医学杂志, 2016, 32 (1): 37- 42. |
22 |
Artopoulos A , Buytaert JA , Dirckx JJ , et al. Comparison of the accuracy of digital stereophotogrammetry and projection moiré profilometry for three-dimensional imaging of the face[J]. Int J Oral Maxillofac Surg, 2014, 43 (5): 654- 662.
doi: 10.1016/j.ijom.2013.10.005 |
23 |
Winder RJ , Darvann TA , McKnight W , et al. Technical validation of the Di3D stereophotogrammetry surface imaging system[J]. Br J Oral Maxillofac Surg, 2008, 46 (1): 33- 37.
doi: 10.1016/j.bjoms.2007.09.005 |
24 |
Lo Russo L , Di Gioia C , Salamini A , et al. Integrating intraoral, perioral, and facial scans into the design of digital dentures[J]. J Prosthet Dent, 2020, 123 (4): 584- 588.
doi: 10.1016/j.prosdent.2019.05.030 |
25 |
Swennen G , Pottel L , Haers PE . Custom-made 3D-printed face masks in case of pandemic crisis situations with a lack of commercially available FFP2/3 masks[J]. Int J Oral Maxillofac Surg, 2020, 49 (5): 673- 677.
doi: 10.1016/j.ijom.2020.03.015 |
26 | Mai H , Lee D . The effect of perioral scan and artificial skin markers on the accuracy of virtual dentofacial integration: stereophotogrammetry versus smartphone three-dimensional face-scanning[J]. Int J Environ Res Public Health, 2021, 18 (1): 229. |
27 |
Duran GS , Dindaroglu F , Kutlu P . Hard- and soft-tissue symmetry comparison in patients with Class Ⅲ malocclusion[J]. Am J Orthod Dentofacial Orthop, 2019, 155 (4): 509- 522.
doi: 10.1016/j.ajodo.2018.05.021 |
28 | 史雨林, 商洪涛, 田磊, 等. 骨性Ⅲ类错畸形患者双颌手术前后面部软组织变化的三维研究[J]. 中国修复重建外科杂志, 2018, 32 (5): 612- 616. |
29 | 刘文静, 史雨林, 许方方, 等. 偏突颌畸形患者手术前后面部软组织的三维测量研究[J]. 现代生物医学进展, 2018, 18 (14): 2669- 2673. |
30 | Yamamoto S , Miyachi H , Fujii H , et al. Intuitive facial imaging method for evaluation of postoperative swelling: A combination of 3-dimensional computed tomography and laser surface scanning in orthognathic surgery[J]. J Oral Maxillofac Surg, 2016, 74 (12): 2501- 2506. |
31 |
Özsoy U , Uysal H , Hizay A , et al. Three-dimensional objective evaluation of facial palsy and follow-up of recovery with a handheld scanner[J]. J Plast Reconstr Aesthet Surg, 2021, 74 (12): 3404- 3414.
doi: 10.1016/j.bjps.2021.05.003 |
32 | 王勇, 赵一姣, 司燕. 与三维测量有关的名词浅析[J]. 中华口腔正畸学杂志, 2009, 16 (2): 111- 113. |
33 | 陈俊锴, 孙玉春, 陈虎, 等. 口内三维扫描仪扫描精度的定量评价方法研究[J]. 中华口腔医学杂志, 2021, 56 (9): 920- 925. |
34 | 曹悦, 陈俊锴, 邓珂慧, 等. 三款口内三维扫描仪获取无牙颌红膏初印模精度的对比评价[J]. 北京大学学报(医学版), 2020, 52 (1): 129- 137. |
35 | Rudy HL , Wake N , Yee J , et al. Three-dimensional facial scanning at the fingertips of patients and surgeons: accuracy and precision testing of iphone Ⅹ three-dimensional scanner[J]. Plast Reconstr Surg, 2020, 146 (6): 1407- 1417. |
36 | 赵一姣, 熊玉雪, 杨慧芳, 等. 3种不同原理颜面部扫描仪测量精度的评价[J]. 北京大学学报(医学版), 2014, 46 (1): 76- 80. |
37 | Amornvit P , Sanohkan S . The accuracy of digital face scans obtained from 3d scanners: An in vitro study[J]. Int J Environ Res Public Health, 2019, 16 (24): 5061. |
38 | Petrides G , Clark JR , Low H , et al. Three-dimensional scanners for soft-tissue facial assessment in clinical practice[J]. J Plast Reconstr Aesthet Surg, 2021, 74 (3): 605- 614. |
[1] | Xiaotong LING,Liuyang QU,Danni ZHENG,Jing YANG,Xuebing YAN,Denggao LIU,Yan GAO. Three-dimensional radiographic features of calcifying odontogenic cyst and calcifying epithelial odontogenic tumor [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 131-137. |
[2] | Da-wei WANG,Hua-dong WANG,Li LI,Xin YIN,Wei HUANG,Ji-dong GUO,Ya-feng YANG,Yi-hao LIU,Yang ZHENG. Efficacy analysis of autologous facet joint bone block in lumbar interbody fusion of osteoporosis patients [J]. Journal of Peking University (Health Sciences), 2023, 55(5): 899-909. |
[3] | Qian DING,Wen-jin LI,Feng-bo SUN,Jing-hua GU,Yuan-hua LIN,Lei ZHANG. Effects of surface treatment on the phase and fracture strength of yttria- and magnesia-stabilized zirconia implants [J]. Journal of Peking University (Health Sciences), 2023, 55(4): 721-728. |
[4] | Wen ZHANG,Xiao-jing LIU,Zi-li LI,Yi ZHANG. Effect of alar base cinch suture based on anatomic landmarks on the morphology of nasolabial region in patients after orthognathic surgery [J]. Journal of Peking University (Health Sciences), 2023, 55(4): 736-742. |
[5] | Wei-wei LI,Hu CHEN,Yong WANG,Yu-chun SUN. Research on friction and wear behaviors of silicon-lithium spray coating on zirconia ceramics [J]. Journal of Peking University (Health Sciences), 2023, 55(1): 94-100. |
[6] | Hao-zhe YU,Wei-zhen ZENG,Wen-yu WU,Zhong-qiang YAO,Yun FENG. Evaluation of ocular surface status and function in primary Sjögren's syndrome with hypothyroidism [J]. Journal of Peking University (Health Sciences), 2022, 54(4): 705-711. |
[7] | Hao LUO,Fu-cong TIAN,Xiao-yan WANG. Surface roughness, gloss and sequential polishing times of various chairside computer aided design/manufacturing restorative materials [J]. Journal of Peking University (Health Sciences), 2022, 54(3): 565-571. |
[8] | WANG Zheng,DING Qian,GAO Yuan,MA Quan-quan,ZHANG Lei,GE Xi-yuan,SUN Yu-chun,XIE Qiu-fei. Effect of porous zirconia ceramics on proliferation and differentiation of osteoblasts [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 31-39. |
[9] | LI Si-yu,DUAN Xue-fei,CAO Ye. Evaluation of the effect of using ultrasonic instruments to improve the shoulder of the preparations [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 88-94. |
[10] | Ren-tao TANG,Xin-hai LI,Jiang-li YU,Lin FENG,Xue-jun GAO. Evaluation of microtensile bond strength between resin composite and glass ceramic [J]. Journal of Peking University (Health Sciences), 2020, 52(4): 755-761. |
[11] | Jing-ying HU,Li LI,Qian-mei ZHOU,Rui-yu DING,Ran SHANG,Wei BAI. Influence of different mixing pads on physical and mechanical properties of glass ionomer cement [J]. Journal of Peking University(Health Sciences), 2019, 51(5): 964-967. |
[12] | Chao WU,Zhen-yu WANG,Guo-zhong LIN,Tao YU,Bin LIU,Yu SI,Yi-bo ZHANG,Yuan-chao LI. Biomechanical changes of sheep cervical spine after unilateral hemilaminectomy and different degrees of facetectomy [J]. Journal of Peking University(Health Sciences), 2019, 51(4): 728-732. |
[13] | JIA Peng-chen, YANG Gang, HU Wen-jie, ZHAO Yi-jiao, LIU Mu-qing. Preliminary study on the accuracy of infrabony root surface area of single-root teeth by periapical films [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 91-97. |
[14] | ZHANG Hao-yu, JIANG Ting, CHENG Ming-xuan, ZHANG Yu-wei. Wear intensity and surface roughness of microhybrid composite and ceramic occlusal veneers on premolars after the thermocycling and cyclic mechanical loading tests [J]. Journal of Peking University(Health Sciences), 2018, 50(1): 73-77. |
[15] | LIANG Nai-wen, SHI Lei,HUANG Ying,DENG Xu-liang. Role of different scale structures of titanium implant in the biological behaviors of human umbilical vein endothelial cells [J]. Journal of Peking University(Health Sciences), 2017, 49(1): 43-048. |
|