北京大学学报(医学版) ›› 2017, Vol. 49 ›› Issue (1): 86-091. doi: 10.3969/j.issn.1671-167X.2017.01.015

• 论著 • 上一篇    下一篇

数字化全口义齿个别托盘制作与临床应用时间

魏菱1,陈虎2,周永胜1,孙玉春2,潘韶霞1△   

  1. (北京大学口腔医学院·口腔医院, 1. 修复科, 2. 口腔医学数字化研究中心,口腔修复教研室口腔数字化医疗技术和材料国家工程实验室口腔数字医学北京市重点实验室,北京100081)
  • 出版日期:2017-02-18 发布日期:2017-02-18
  • 通讯作者: 潘韶霞 E-mail:panshaoxia@vip.163.com
  • 基金资助:

    首都医学发展科研基金(2016-1-4101)、北京大学口腔医院临床新技术新疗法项目基金(2016)资助

Evaluation of production and clinical working time of computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays for complete denture

WEI Ling1,CHEN Hu2,ZHOU Yong-sheng1,SUN Yu-chun2,PAN Shao-xia1△   

  1. (1.Department of Prosthodontics, 2. Center for Digital Dentistry, Faculty of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China)
  • Online:2017-02-18 Published:2017-02-18
  • Contact: PAN Shao-xia E-mail:panshaoxia@vip.163.com
  • Supported by:

    Supported by the Capital Foundation for Medical Research and Development (2016-1-4101) and the Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology (2016)

摘要:

目的:比较三维打印数字化无牙颌个别托盘与传统无牙颌个别托盘的技工制作用时及临床操作用时,从临床时间花费角度对数字化个别托盘进行适用性验证。方法: 招募20名无牙颌患者进行前瞻性、单盲、自身随机对照临床试验,每人均采用北京大学口腔医院功能易适性数字化全口义齿(functional suitable denture, FSD)系统修复方式及传统全口义齿修复方式制作无牙颌个别托盘,将利用两种方式制作的个别托盘制取终印模后制作全口义齿,记录技工制作用时及临床操作用时。结果: 三维打印数字化无牙颌个别托盘与传统无牙颌个别托盘的制作平均人工用时分别为(28.6±2.9) min、(31.1±5.7) min,两者差异有统计学意义(P<0.05)。分别用三维打印数字化无牙颌个别托盘与传统无牙颌个别托盘制取终印模的临床操作平均用时为(23.4±11.5) min、(25.4±13.0)min,两者差异有统计学意义(P<0.05)。结论: 三维打印数字化无牙颌个别托盘的技工制作用时及临床操作用时均小于传统无牙颌个别托盘,采用三维打印数字化无牙颌个别托盘制作全口义齿能够节约技工的制作时间及临床操作用时,且由于其不需要灌注初印模,可节省印模材料及模型材料,在全口义齿修复治疗中,是值得临床推广的制作无牙颌个别托盘的方式。

关键词:  计算机辅助设计, 计算机辅助制造, 义齿, 全口, 成像, 三维, 个别托盘

Abstract:

Objective: To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Methods: Twenty edentulous patients were recruited into this study, which was prospective, single blind, rando-mized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. Results: The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant diffe-rence in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (P<0.05). Conclusion: The average time spent on fabricating three-dimensional printing custom trays using FSD system and making the final impression with the trays are less than those of the conventional custom trays fabricated manually, which reveals that the FSD three-dimensional printing custom trays is less time-consuming both in the clinical and laboratory process than the conventional custom trays. In addition, when we manufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being popularized.

Key words: Computer-aided design, Computer-aided manufacturing, Denture, complete, Imaging, three-dimensional, Custom tray

中图分类号: 

  • R783.6
[1] 刁畅, 王时敏, 李曼, 潘韶霞, 刘洋. 牙列缺失种植覆盖义齿集中𬌗型的临床研究[J]. 北京大学学报(医学版), 2026, 58(1): 133-138.
[2] 温奥楠, 张晓会, 杨咏涛, 高梓翔, 李文博, 单珅瑶, 商相宜, 田淯文, 郭殊玮, 王艺蓁, 王勇, 赵一姣. 基于非刚性配准构建三维颜面微笑仿真序列数据的方法[J]. 北京大学学报(医学版), 2026, 58(1): 139-144.
[3] 邵梁, 马雯洁, 陈莹, 丁茜, 张磊. 上颌切牙前伸和正中咬合接触解剖特征的数字化测量与分析[J]. 北京大学学报(医学版), 2026, 58(1): 99-106.
[4] 王翠萍, 陈哲, 程永静. 超微血流成像评估与膝骨关节炎临床症状的关联研究[J]. 北京大学学报(医学版), 2025, 57(6): 1096-1100.
[5] 宋凤岐, 徐心雨, 刘筱菁, 李自力. 上颌骨前部和整体顺时针旋转改善骨性Ⅲ类牙颌面畸形患者鼻旁凹陷的对比[J]. 北京大学学报(医学版), 2025, 57(5): 980-988.
[6] 肖宇嘉, 毛渤淳, 周彦恒. 姿势性微笑的三维形态学研究[J]. 北京大学学报(医学版), 2025, 57(5): 989-995.
[7] 王泽远, 于栓宝, 郑浩轲, 陶金, 范雅峰, 张雪培. 基于临床特征和多参数MRI的前列腺癌盆腔淋巴结转移的术前预测模型[J]. 北京大学学报(医学版), 2025, 57(4): 684-691.
[8] 宁圆, 张晓盈, 李雪, 李原, 何菁, 金月波. 干燥综合征并发乳腺淋巴瘤1例[J]. 北京大学学报(医学版), 2025, 57(4): 808-811.
[9] 孙建军, 马千权, 尹晓亮, 杨辰龙, 张嘉, 陈素华, 吴超, 谢京城, 韩芸峰, 林国中, 司雨, 杨军, 邬海博, 赵强. 任意维度重建磁共振对骶管囊肿进行精准分型对于指导微创手术和康复的意义[J]. 北京大学学报(医学版), 2025, 57(2): 303-308.
[10] 仇师禹, 练洋, 康一帆, 张雷, 蔡义望, 单小峰, 蔡志刚. 基于下颌骨数据库和全连接神经网络的三维检索模型辅助下的下颌骨个性化重建[J]. 北京大学学报(医学版), 2025, 57(2): 360-368.
[11] 马丽娟, 腾雍辉, 王勇, 赵一姣, 张馨月, 秦庆钊, 尹东. 乳牙缺失数字化丝圈间隙保持器的三维有限元分析[J]. 北京大学学报(医学版), 2025, 57(2): 376-383.
[12] 朱玉佳, 沈华, 温奥楠, 高梓翔, 秦庆钊, 单珅瑶, 李文博, 傅湘玲, 赵一姣, 王勇. 三维颌面对称参考平面智能构建的深度学习算法[J]. 北京大学学报(医学版), 2025, 57(1): 113-120.
[13] 徐昕恺, 赵建江, 田素坤, 刘中宁, 赵晓一, 赵晓波, 江腾飞, 陈晓军, 马超, 孙玉春. 集成压缩气流系统扫描头辅助获取液体干扰表面三维数据精度评价[J]. 北京大学学报(医学版), 2025, 57(1): 121-127.
[14] 吴灵, 方嘉琨, 刘筱菁, 李自力, 李阳, 王晓霞. 基于牙颌面畸形患者三维颅面特征相似性度量模型的建立及评估[J]. 北京大学学报(医学版), 2025, 57(1): 128-135.
[15] 康一帆, 葛严军, 吕晓鸣, 谢尚, 单小峰, 蔡志刚. 即刻种植体支持式义齿修复的血管化髂骨瓣重建下颌骨缺损[J]. 北京大学学报(医学版), 2025, 57(1): 78-84.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!