Journal of Peking University (Health Sciences) ›› 2021, Vol. 53 ›› Issue (1): 76-82. doi: 10.19723/j.issn.1671-167X.2021.01.012
Previous Articles Next Articles
FANG Shuo-bo1,2,YANG Guang-ju1,2,KANG Yan-feng1,2,SUN Yu-chun1,XIE Qiu-fei1,2,Δ()
CLC Number:
[1] |
Clark GT. The TMJ repositioning appliance: a technique for construction, insertion, and adjustment[J]. Cranio, 1986,4(1):37-46.
doi: 10.1080/08869634.1986.11678129 pmid: 3456393 |
[2] |
Aslanidou K, Kau CH, Vlachos C, et al. The fabrication of a customized occlusal splint based on the merging of dynamic jaw tracking records, cone beam computed tomography, and CAD-CAM digital impression[J]. J Orthod Sci, 2017,6(3):104-109.
doi: 10.4103/jos.JOS_61_16 pmid: 28717635 |
[3] |
Kühnöl C, Kordaß B. Digital workflow for TMD diagnostics and bite alteration: description of a case treated using Sicat Function[J]. Int J Comput Dent, 2019,22(3):283-292.
pmid: 31463492 |
[4] | 杨德圣, 韩科, 周书敏, 等. 临床弹响消失牙合位作为调位牙合垫治疗牙合位的研究[J]. 中华口腔医学杂志, 2000,35(6):465-466. |
[5] | 陈慧敏, 傅开元, 李优伟, 等. 再定位牙合垫戴入前后颞下颌关节盘和髁突的位置改变[J]. 华西口腔医学杂志, 2009,27(4):408-412. |
[6] |
Dao TT, Lavigne G. Oral splints: the crutches for temporomandi-bular disorders and bruxism?[J]. Crit Rev Oral Biol Med, 1998,9(3):345-361.
doi: 10.1177/10454411980090030701 pmid: 9715371 |
[7] | 佘文珺, 谢俊良, 翁维民. 下颌运动轨迹描记在无牙颌颌位记录中的应用[J]. 临床口腔医学杂志, 2018,34(1):22-24. |
[8] |
Li W, Xie Q, Wang Y, et al. A pilot study of digital recording of edentulous jaw relations using a handheld scanner and specially designed headgear[J]. Sci Rep, 2018,8(1):8975.
doi: 10.1038/s41598-018-27277-5 pmid: 29895978 |
[9] | 吴冰, 吴国锋. 口腔修复CAD/CAM系统中的虚拟牙合架[J]. 实用口腔医学杂志, 2016,32(2):293-297. |
[10] |
Gärtner C, Kordaß B. The virtual articulator: development and evaluation[J]. Int J Comput Dent, 2003,6(1):11-24.
pmid: 12838585 |
[11] |
Bohner L, Gamba DD, Hanisch M, et al. Accuracy of digital technologies for the scanning of facial, skeletal, and intraoral tissues: A systematic review[J]. J Prosthet Dent, 2019,121(2):246-251.
doi: 10.1016/j.prosdent.2018.01.015 pmid: 30017156 |
[12] | 宋杨, 孙玉春, 赵一姣, 等. 牙颌模型三维扫描仪精度定量评价[J]. 北京大学学报(医学版), 2013,45(1):140-144. |
[13] |
Andreiotelli M, Kamposiora P, Papavasiliou G. Digital data management for CAD/CAM technology. An update of current systems[J]. Eur J Prosthodont Restor Dent, 2013,21(1):9-15.
pmid: 23682504 |
[14] | Fang JJ, Kuo TH. Tracked motion-based dental occlusion surface estimation for crown restoration[J]. Computer Aided Design, 2009,41(4):315-323. |
[15] | Li L, Sun Y, Wang Y, et al. Accuracy of a novel virtual articulator for recording three-dimensional dentition[J]. Int J Pros-thodont, 2020,33(4):441-451. |
[16] | 陈磊, 张豪, 冯海兰, 等. 颅颌运动仿真系统牙合接触精度初探[J]. 中华口腔医学杂志, 2010,45(2):98-101. |
[17] |
Uechi J, Okayama M, Shibata T, et al. A novel method for the 3-dimensional simulation of orthognathic surgery by using a multimodal image-fusion technique[J]. Am J Orthod Dentofacial Orthop, 2006,130(6):786-798.
doi: 10.1016/j.ajodo.2006.03.025 pmid: 17169742 |
[18] |
Swennen GR, Mommaerts MY, Abeloos J, et al. The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model[J]. J Craniofac Surg, 2007,18(3):533-539.
doi: 10.1097/scs.0b013e31805343df pmid: 17538314 |
[19] |
Nkenke E, Zachow S, Benz M, et al. Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgery[J]. Dentomaxillofac Radiol, 2004,33(4):226-232.
doi: 10.1259/dmfr/27071199 pmid: 15533975 |
[20] | 赵一姣, 原福松, 谢晓艳, 等. 牙颌模型激光扫描数据与锥形束CT数据配准方法的精度比较[J]. 中华口腔医学杂志, 2013,48(3):173-176. |
[21] | 谢秋菲. 牙合垫在口腔疾病治疗中的应用现状及未来发展趋势[J]. 中华口腔医学杂志, 2019,58(8):515-521. |
[22] |
Dedem P, Türp JC. Digital Michigan splint: from intraoral scanning to plasterless manufacturing[J]. Int J Comput Dent, 2016,19(1):63-76.
pmid: 27027103 |
[23] |
Berntsen C, Kleven M, Heian M, et al. Clinical comparison of conventional and additive manufactured stabilization splints[J]. Acta Biomater Odontol Scand, 2018,4(1):81-89.
doi: 10.1080/23337931.2018.1497491 pmid: 30128331 |
[24] | 王时敏, 李峥, 王冠博, 等. 全程数字化夜磨牙保护牙合垫的制作和初步应用[J]. 北京大学学报(医学版), 2019,51(1):111-116. |
[25] |
Li Z, Wang S, Ye H, et al. Preliminary clinical application of complete workflow of digitally designed and manufactured sports mouthguards[J]. Int J Prosthodont, 2020,33(1):99-104.
doi: 10.11607/ijp.6348 pmid: 31860919 |
[1] | Xinyu XU,Ling WU,Fengqi SONG,Zili LI,Yi ZHANG,Xiaojing LIU. Mandibular condyle localization in orthognathic surgery based on mandibular movement trajectory and its preliminary accuracy verification [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 57-65. |
[2] | Sui LI,Wenjie MA,Shimin WANG,Qian DING,Yao SUN,Lei ZHANG. Trueness of different digital design methods for incisal guidance of maxillary anterior implant-supported single crowns [J]. Journal of Peking University (Health Sciences), 2024, 56(1): 81-87. |
[3] | FENG Sha-wei,GUO Hui,WANG Yong,ZHAO Yi-jiao,LIU He. Initial establishment of digital reference standardized crown models of the primary teeth [J]. Journal of Peking University (Health Sciences), 2022, 54(2): 327-334. |
[4] | LI Yi,WONG Lai U,LIU Xiao-qiang,ZHOU Ti,LYU Ji-zhe,TAN Jian-guo. Marginal features of CAD/CAM laminate veneers with different materials and thicknesses [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 140-145. |
[5] | QIU Shu-ting,ZHU Yu-jia,WANG Shi-min,WANG Fei-long,YE Hong-qiang,ZHAO Yi-jiao,LIU Yun-song,WANG Yong,ZHOU Yong-sheng. Preliminary clinical application verification of complete digital workflow of design lips symmetry reference plane based on posed smile [J]. Journal of Peking University (Health Sciences), 2022, 54(1): 193-199. |
[6] | XU Xiao-xiang,CAO Ye,ZHAO Yi-jiao,JIA Lu,XIE Qiu-fei. In vitro evaluation of the application of digital individual tooth tray in the impression making of mandibular full-arch crown abutments [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 54-61. |
[7] | YUE Zhao-guo,ZHANG Hai-dong,YANG Jing-wen,HOU Jian-xia. Comparison of residual cement between CAD/CAM customized abutments and stock abutments via digital measurement in vitro [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 69-75. |
[8] | LI Zheng,LIU Yu-shu,WANG Shi-min,ZHANG Rui,JIA Lu,YE Hong-qiang,HU Wen-jie,ZHAO Wen-yan,LIU Yun-song,ZHOU Yong-sheng. Application of biocopy function of temporary crown occlusal morphology in patients with severe attrition [J]. Journal of Peking University (Health Sciences), 2021, 53(1): 62-68. |
[9] | Lang YOU,Ke-hui DENG,Wei-wei LI,Yi-jiao ZHAO,Yu-chun SUN,Yong-sheng ZHOU. Visual sensitivity threshold of lateral view of nasolabial Angle changes in edentulous jaw patients [J]. Journal of Peking University(Health Sciences), 2020, 52(1): 107-112. |
[10] | Shuo CHEN,Yang HE,Jin-gang AN,Yi ZHANG. Application of computer-aided virtual mandibular position in the simultaneous treatment of children with temporomandibular joint ankylosis and jaw deformity [J]. Journal of Peking University(Health Sciences), 2019, 51(5): 954-958. |
[11] | Jing WANG,Jun-peng CHEN,Yang WANG,Xiang-liang XU,Chuan-bin GUO. Application of digital mandibular movement record and masticatory muscle electromyography in the evaluation of stomatognathic function in patients with mandibular tumor [J]. Journal of Peking University(Health Sciences), 2019, 51(3): 571-578. |
[12] | Kuan-paul WANG,Hong-qiang YE,Hu CHEN,Yong WANG,Yu-chun SUN,Yong-sheng ZHOU. Establishment and preliminary clinical evaluation of edentulous custom trays designed and fabricated by chair-side CAD and 3D printing systems [J]. Journal of Peking University(Health Sciences), 2019, 51(2): 349-355. |
[13] | Xin-xin LI,Yu-shu LIU,Yu-chun SUN,Hu CHEN,Hong-qiang YE,Yong-sheng ZHOU. Evaluation of one-piece polyetheretherketone removable partial denture fabricated by computer-aided design and computer-aided manufacturing [J]. Journal of Peking University(Health Sciences), 2019, 51(2): 335-339. |
[14] | Shi-min WANG,Zheng LI,Guan-bo WANG,Hong-qiang YE,Yun-song LIU,Dai TONG,Wen-hui GAO,Yong-sheng ZHOU. Preliminary clinical application of complete digital workflow of design and manufacturing occlusal splint for sleep bruxism [J]. Journal of Peking University(Health Sciences), 2019, 51(1): 105-110. |
[15] | PENG Li, WANG Zu-hua, SUN Yu-chun, QU Wei,HAN Yang, LIANG Yu-hong. Computer aided design and three-dimensional printing forapicoectomy guide template [J]. Journal of Peking University(Health Sciences), 2018, 50(5): 905-910. |
|