北京大学学报(医学版) ›› 2015, Vol. 47 ›› Issue (5): 834-837. doi: 10.3969/j.issn.1671-167X.2015.05.020

• 论著 • 上一篇    下一篇

热牙胶充填系统携热头工作状态下的实际温度

渠薇1,白伟2,梁宇红1,3△,高学军1   

  1. (1.北京大学口腔医学院·口腔医院牙体牙髓科,北京100081; 2.北京大学口腔医学院·口腔医院口腔材料研究室,北京100081;3.北京大学国际医院口腔医学科,北京102206)
  • 出版日期:2015-10-18 发布日期:2015-10-18
  • 通讯作者: 梁宇红 E-mail:leungyuhong@sina.com

Real temperature of the continuous-wave pluggers

QU Wei1, BAI Wei2, LIANG Yu-hong1,3△, GAO Xue-jun1   

  1. (1.Department of Cariology and Endodontology, 2.Dental Material Laboratory, Peking University School and Hospital of Stomatology, Beijing 100081, China; 3. Dental Clinic, Peking University International Hospital, Beijing 102206, China)
  • Online:2015-10-18 Published:2015-10-18
  • Contact: LIANG Yu-hong E-mail:leungyuhong@sina.com

摘要:

目的:测量热牙胶充填系统携热头工作状态下的实际温度,为临床研究热损伤、观察温度升高对充填材料影响提供理论依据。方法:使用双通道K型电偶温度计测量3种热牙胶充填系统的不同大小携热头和携热头不同部位(工作端尖端和距尖端2 mm、5 mm、10 mm处)的实际温度(设置温度200 ℃),重复测量5次,比较不同充填系统、不同携热头大小、不同测量位点的实际工作温度和设置温度的差异,并用单因素方差分析法分析各因素的影响。结果:BeeFill 40/0.03携热头尖端工作温度最高(198.7±7.7)℃,与设定温度200 ℃差异无统计学意义(P>0.05),其余携热头工作温度均低于设定温度200 ℃,差异有统计学意义(P<0.05),BeeFill 60/0.06携热头距尖端10 mm处温度最低(69.9±4.0) ℃。所有携热头尖端(0 mm)及尖端2 mm处温度较高(112.1~198.7 ℃,中位数140.8 ℃)。结论:大部分热牙胶充填系统的携热头实际工作温度低于设定温度200 ℃。

关键词:  温度, 根管充填材料, 携热头

Abstract:

Objective: To measure the real temperatures on the pluggers of three continuous-wave devices, and to provide theoretical reference to evaluate thermal damage and heat’s influence on the filling materials.  Methods: The dual channel K type thermocouple was contacted to various sizes’ pluggers in three different continuous-wave devices (BeeFill, Elements, B&L), and the highest temperatures at different points (tip, and 2 mm, 5 mm, 10 mm from the tip) of the pluggers (preset temperature was 200 ℃) were recorded. The measurements were performed 5 times. T-test was used to compare the real temperatures at the tips with that set on the display and one-way ANOVA was used to compare the temperatures of the pluggers in different devices, sizes and points. Results: The highest temperature was at the tip of BeeFill 40/0.03 plugger (198.7±7.7) ℃, but there was on statistical differences between that and the preset temperature 200 ℃. The temperatures of the remaining pluggers were obviously lower than 200 ℃(P<0.05). The lowest temperature of the pluggers was detected at 10 mm from the tip of BeeFill 60/0.06 plugger (69.9±4.0) ℃. The highest temperature of each plugger was detected at the tip or 2 mm from the tip (112.1 to 198.7 ℃,and the median was 140.8 ℃). Conclusion: The real temperature of most continuous-wave pluggers included in this study is below the set temperature 200 ℃.

Key words: Temperature, Root canal filling materiak, Plugger

中图分类号: 

  • R783.1
[1] 何佩瑶,包旭东. 常温流动牙胶封闭剂GuttaFlow2单尖充填弯曲根管的封闭效果[J]. 北京大学学报(医学版), 2024, 56(1): 99-105.
[2] 臧海玲,王月,梁宇红. 有机溶剂对牙本质表面残留根管封闭剂的清除效果[J]. 北京大学学报(医学版), 2018, 50(1): 63-68.
[3] 范聪,袁重阳,张继川,王晓燕. 牙胶类根管充填材料导热性对根尖封闭的影响[J]. 北京大学学报(医学版), 2017, 49(1): 110-114.
[4] 乔迪, 董艳梅, 高学军. 体外评价新型根尖倒充填材料iRoot的生物学性能[J]. 北京大学学报(医学版), 2016, 48(2): 324-329.
[5] 陈小贤, 林碧琛, 钟洁, 葛立宏. 改良乳牙根管充填材料体内降解匹配性与临床效果[J]. 北京大学学报(医学版), 2015, 47(3): 529-535.
[6] 卫彦, 严红, 马琦. 四种根管封闭剂的根尖封闭性研究[J]. 北京大学学报(医学版), 2008, 40(1): 71-73.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!