北京大学学报(医学版) ›› 2019, Vol. 51 ›› Issue (5): 851-855. doi: 10.19723/j.issn.1671-167X.2019.05.010

• 论著 • 上一篇    下一篇

非体外循环冠状动脉旁路移植术中桥血管血流对术后近中期预后的影响

孙文强,赵舟,高卿,韩增强,杨威,廉波,刘刚,陈生龙,陈彧()   

  1. 北京大学人民医院心脏中心心脏外科, 北京 100044
  • 收稿日期:2017-09-18 出版日期:2019-10-18 发布日期:2019-10-23
  • 通讯作者: 陈彧 E-mail:chenyu@pkuph.edu.cn

Effects of intraoperative graft flow measurements on the early mid-term outcomes after off-pump coronary artery bypass grafting

Wen-qiang SUN,Zhou ZHAO,Qing GAO,Zeng-qiang HAN,Wei YANG,Bo LIAN,Gang LIU,Sheng-long CHEN,Yu CHEN()   

  1. Department of Cardiac Surgery, Heart Center, Peking University People’s Hospital, Beijing 100044, China
  • Received:2017-09-18 Online:2019-10-18 Published:2019-10-23
  • Contact: Yu CHEN E-mail:chenyu@pkuph.edu.cn

RICH HTML

  

摘要:

目的:对非体外循环冠状动脉旁路移植术(off-pump coronary artery bypass,OPCAB)中测定的血流资料和术后近中期结果进行分析,探讨两者间的相关性。方法:回顾性收集2013年1月至2016年6月在北京大学人民医院行单纯OPCAB手术的患者资料,分析并对比患者术中测定的血流指标、术后早期临床事件及术后随访资料。术后早期临床事件包括围手术期心肌梗死、主动脉内球囊反搏(intra-aortic balloon pump,IABP)使用、再次手术、新发心房颤动及院内死亡。结果:共463例患者纳入研究,平均年龄(62.80±8.36)岁,其中女性115例(24.8%),平均吻合桥血管(3.10±0.81)支,共1 435支桥血管,术中血流测定结果显示移植血管平均血流量(mean flow,MF)为(32.34±14.45) mL/min,搏动指数(pulsatility index,PI)为2.87±0.92。23例(5%)患者发生围手术期心肌梗死,IABP使用者11例,术后30 d死亡患者4例。围手术期心肌梗死组的桥血管MF低于无心肌梗死组,而PI高于无心肌梗死组(P<0.05)。其他术后早期临床事件组间比较,其MF、PI值差异均无统计学意义。Logistic回归分析显示移植血管低MF(Wald=5.684,P=0.017,95%CI:0.894~0.989)、高PI(Wald=9.040,P=0.003,95%CI:1.252~2.903)是围手术期心肌梗死的危险因素。随访最长时间37个月,共7例患者死亡,死亡组与生存组间术中血流指标差异均无统计学意义。与动脉桥正常血流组比较,低MF组(MF<10 mL/min)随访期间死亡率较高,差异有统计学意义(OR=9.6,P<0.05)。结论:移植血管低MF、高PI会增加围手术期心肌梗死发生率,动脉桥MF<10 mL/min 会增加患者术后中期死亡率,但仍需进一步研究证实,术中血流测定技术对OPCAB术后近中期结果有一定的预测价值。

关键词: 冠状动脉旁路移植术, 非体外循环, 监测, 手术中, 冠状动脉循环, 血流测量, 手术后期间

Abstract:

Objective: To investigate and analyze the relationship between intraoperative graft flow measurements and the early mid-term outcomes after off-pump coronary artery bypass grafting (OPCAB). Methods: Patients who underwent isolated OPCAB in the Department of Cardiac Surgery of Peking University People’s Hospital from January 2013 to June 2016 were included. Perioperative characteristics, graft flow measurements and postoperative follow-up outcomes were retrospectively collected. Comparison was made between flow measurements of grafts and the early mid-term outcomes. Flow measurements of grafts included the mean flow (MF) and the pulsatility index (PI). The early outcomes included peri-operative myocardial infarction (PMI), use of an intra-aortic balloon pump (IABP), reoperation for all causes, new-onset atrial fibrillation and in-hospital or 30-day mortality. Results: A total of 463 patients were included in the study. Mean age was (62.80±8.36) years, and 24.8% were females. The total number of grafts was 1 435, which averaged 3.10 grafts per patient. The MF and PI were separately (32.34±14.45) mL/min and 2.87±0.92. Of all the patients, 23(5%) had PMI, and 11 used IABP. Observed in-hospital or 30-day mortality was 0.86% (4 patients). Compared with non-PMI group, the MF was lower and the PI was higher in the PMI group (P<0.05). However, the differences of other early outcomes had no statistical significance between the PMI group and the non-PMI group. The lower MF (Wald=5.684, P=0.017, 95%CI: 0.894-0.989) and the higher PI (Wald=9.040, P=0.003, 95%CI: 1.252-2.903)were risk factors of PMI in multivariable Logistic regression modeling. The longest follow-up time was 37 months, and 7 patients died. The differences of graft flow measurements between the surviving group and the non-survivors had no statistical significance, but overall mid-term survival was lower in patients with poor left internal mammary artery (LIMA) to left anterior descending artery (LAD) graft flow (MF<10 mL/min; OR=9.6, P<0.05). Conclusion: Intraoperative graft flow parameters during OPCAB can predict the early mid-term outcomes. The lower MF and the higher PI should increase the rate of PMI. A lower flow of LIMA to LAD graft (<10 mL/min) should increase the rate of midterm mortality, but further research will be needed to confirm and explore the findings.

Key words: Coronary artery bypass, off-pump, Monitoring, intraoperative, Coronary circulation, Flow measurement, Postoperative period

中图分类号: 

  • R541.4

表1

患者的基线资料"

Items All patients (n=463)
Age/years, x?±s 62.80±8.36
Female, n(%) 115 (24.8)
BMI, x?±s 25.71±3.25
AMI, n(%) 129 (27.9)
LM, n(%) 109 (23.5)
NYHA class Ⅲ-Ⅳ, n(%) 82 (18.1)
Hypertension, n(%) 289 (62.4)
DM, n(%) 175 (37.8)
PVD, n(%) 13 (2.8)
CVD, n(%) 63 (13.6)
History of smoking, n(%) 193 (41.7)
LVEF/% 61.91±10.10

表2

围手术期心肌梗死组与无围手术期心肌梗死组资料比较"

Items PMI group (n=23) Non-PMI group (n=440) P
Age/years, x?±s 62.96±8.61 62.80±8.36 0.931
Female, n(%) 3 (13) 112 (25.5) 0.179
BMI, x?±s 24.66±2.93 25.77±3.26 0.119
AMI, n(%) 7 (30.4) 122 (27.8) 0.783
LM, n(%) 4 (17.4) 105 (23.9) 0.476
NYHA class Ⅲ-Ⅳ, n(%) 1 (4.5) 81 (18.9) 0.157
Hypertension, n(%) 14 (60.9) 275 (62.5) 0.875
DM, n(%) 5 (21.7) 170 (38.6) 0.103
CVD, n(%) 2 (8.7) 61 (13.9) 0.692
MF/(mL/min) , x?±s 22.52±12.76 32.85±14.36 0.001
PI, x?±s 3.80±1.69 2.82±0.84 0.011

表3

PMI的多因素分析"

Items B SE Wald P OR 95%CI
MF -0.062 0.026 5.684 0.017 0.940 0.894-0.989
PI 0.645 0.215 9.040 0.003 1.906 1.252-2.903
[1] Thygesen K, Alpert JS, Jaffe AS , et al. Third universal definition of myocardial infarction[J]. J Am Coll Cardiol, 2012,60(16):1581-1598.
[2] Hess CN, Lopes RD, Gibson CM , et al. Saphenous vein graft failure after coronary artery bypass surgery: insights from PREVENT Ⅳ[J]. Circulation, 2014,130(17):1445-1451.
[3] Alexander JH, Hafley G, Harrington RA , et al. Effcacy and safety of edifoligide, an E2F transcription factor decoy, for prevention of vein graft failure following coronary artery bypass graft surgery: PREVENT Ⅳ: a randomized controlled trial[J]. JAMA, 2005,294(19):2446-2454.
[4] Task Force on Myocardial Revascularization of the European Society of Cardiology ( ESC) and the European Association for Cardio-Thoracic Surgery ( EACTS), European Association for Percutaneous Cardiovascular Interventions ( EAPCI), Kolh P , et al. Guidelines on myocardial revascularization[J]. Eur J Cardiothorac Surg, 2010,38(Suppl):S1-S52.
[5] Waseda K, Ako J, Hasegawa T , et al. Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft[J]. JACC Cardiovasc Imaging, 2009,2(5):604-612.
[6] 高长青, 张涛, 李伯君 , 等. 中国人移植的乳内动脉平均流量测定及影响因素[J]. 中国胸心血管外科临床杂志, 2004,11(2):84-87.
[7] 张涛, 高长青, 李伯君 , 等. 冠状动脉旁路移植术大大隐静脉桥的平均流量及影响因素分析[J]. 中华外科杂志, 2006,44(2):80-82.
[8] Herman C, Sullivan JA, Buth K , et al. Intraoperative graft flow measurements during coronary artery bypass surgery predict in-hospital outcomes[J]. Interact Cardiovasc Thorac Surg, 2008,7(4):582-585.
[9] D’Ancona G, Karamanoukian HL, Ricci M , et al. Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting[J]. Eur J Cardiothorac Surg, 2000,17(3):287-293.
[10] Walker PF, Daniel WT, Moss E , et al. The accuracy of transit time flow measurement in predicting graft patency after coronary artery bypass grafting[J]. Innovations (Phila), 2013,8(6):416-419.
[11] Lehnert P, Møller CH, Damgaard S , et al. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up[J]. J Card Surg, 2015,30(1):47-52.
[12] Khaleel MS, Dorheim TA, Duryee MJ , et al. High-pressure distention of the saphenous vein during preparation results in increased markers of inflammation: a potential mechanism for graft failure[J]. Ann Thorac Surg, 2012,93(2):552-558.
[13] 冠状动脉旁路移植术围术期抗血小板治疗共识专家组. 冠状动脉旁路移植术围术期抗血小板治疗专家共识[J]. 中华胸心血管外科杂志, 2016,32(1):1-8.
[14] Gao G, Zheng Z, Pi Y , et al. Aspirin plus clopidogrel therapy increases early venous graft patency after coronary artery bypass surgery a single-center, randomized, controlled trial[J]. J Am Coll Cardiol, 2010,56(20):1639-1643.
[1] 王飞,秦彩朋,杜依青,刘士军,李清,徐涛. 中危非肌层浸润性膀胱癌的最佳膀胱镜监测强度[J]. 北京大学学报(医学版), 2022, 54(4): 669-673.
[2] 闫辉,逄璐,李雪迎,杨文双,蒋世菊,刘平,闫存玲. 单中心就诊2~18岁儿童胆固醇水平异常发生率及病因分析[J]. 北京大学学报(医学版), 2022, 54(2): 217-221.
[3] 霍阳,周兵,何红彦,赵龙,张雪丽,李静,左玉花,郑宇,任正洪,韩芳,张俊. 腕表式睡眠监测仪与多导睡眠监测的睡眠参数比较和相关性分析[J]. 北京大学学报(医学版), 2021, 53(5): 942-945.
[4] 张绍兴,姚子明,栾胜,王丽,徐颖. 使用多参数压敏式便携睡眠监测系统检测阻塞型睡眠呼吸暂停伴低通气综合征[J]. 北京大学学报(医学版), 2021, 53(3): 608-612.
[5] 杨羽,王胜锋,詹思延. 社交媒体数据在药品上市后安全性监测的应用[J]. 北京大学学报(医学版), 2021, 53(3): 623-627.
[6] 许志锋,凌云鹏,崔仲奇,赵鸿,宫一辰,傅元豪,杨航,万峰. 经左胸前外侧微创冠脉搭桥治疗冠心病多支病变[J]. 北京大学学报(医学版), 2020, 52(5): 863-869.
[7] 陈嘉惠,胡大宇,贾旭,牛薇,邓芙蓉,郭新彪. 大气臭氧短期监测指标与健康年轻人肺功能和气道炎症的关联[J]. 北京大学学报(医学版), 2020, 52(3): 492-499.
[8] 王玉华,张国华,张令令,罗俊丽,高兰,赵绵松. 合并恶性肿瘤的类风湿关节炎74例[J]. 北京大学学报(医学版), 2018, 50(6): 986-990.
[9] 何娜,闫盈盈,应颖秋,伊敏,么改琦,葛庆岗,翟所迪. 持续静脉血液滤过联合体外膜肺氧合治疗1例急性重症胰腺炎的万古霉素个体化治疗方案报道[J]. 北京大学学报(医学版), 2018, 50(5): 915-920.
[10] 吴双胜,杨鹏,李海月,马春娜,王全意. 传染病健康素养水平与传染病症状发生之间的相关性研究[J]. 北京大学学报(医学版), 2018, 50(5): 937-940.
[11] 马运东, 黄东, 陈宇峰, 姜皓云, 刘军华, 孙洪强, 李志宏. 应用于无线多导睡眠监测的皮肤贴电极制备及验证[J]. 北京大学学报(医学版), 2018, 50(2): 358-363.
[12] 张鲁锋,凌云鹏, 杨航, 宫一辰, 宋之明, 万峰. 两种微创旁路移植手术治疗多支冠状动脉病变效果的对比[J]. 北京大学学报(医学版), 2017, 49(6): 1066-1070.
[13] 李西慧,肖锋,张思宇. 不停跳冠状动脉旁路移植术后急性肾损伤的影响因素探讨及3年随访结果[J]. 北京大学学报(医学版), 2017, 49(1): 131-136.
[14] 郁静茹, 金蕾, 肖利华, 靳蕾. 北京通州区神经管缺陷患病率及其与监测时限的关系[J]. 北京大学学报(医学版), 2015, 47(6): 1042-1045.
[15] 张沫, 李昭屏, 李卫虹, 李丹, 刘丽娜, 冯新恒, 高炜. 非冠心病胸痛患者心外膜脂肪与冠状动脉血流储备的相关性[J]. 北京大学学报(医学版), 2014, 46(6): 848-853.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!