北京大学学报(医学版) ›› 2018, Vol. 50 ›› Issue (3): 482-487. doi: 10.3969/j.issn.1671-167X.2018.03.015

• 论著 • 上一篇    下一篇

高效空气过滤净化器对北京市冬季某区居民室内PM2.5及其组分的净化效果

楚梦天,董伟,迟锐,潘璐,李宏宇,胡大宇,杨玄,邓芙蓉△,郭新彪     

  1. (北京大学公共卫生学院劳动卫生与环境卫生学系, 北京100191)
  • 出版日期:2018-06-18 发布日期:2018-06-18
  • 通讯作者: 邓芙蓉 E-mail:lotus321321@126.com
  • 基金资助:
     国家科技部十三五重点研发计划(2016YFC0206506、2017YFC0702701)、美国中华医学基金会项目(CMB 15-228)和国家自然科学基金(81571130090、91543112)资助

Effects of high-efficiency particulate air purifiers on indoor fine particulate matter and its constituents in a district of Beijing during winter

CHU Meng-tian, DONG Wei, CHI Rui, PAN Lu, LI Hong-yu, HU Da-yu, YANG Xuan, DENG Fu-rong△, GUO Xin-biao   

  1. (Department of Occupational and Environmental Health Sciences, Peking University School of Public Health, Beijing 100191, China)
  • Online:2018-06-18 Published:2018-06-18
  • Contact: DENG Fu-rong E-mail:lotus321321@126.com
  • Supported by:
    Supported by the Grants of the National Key Research and Development Program of China (2016YFC0206506, 2017YFC0702701), the Grant of China Medical Board (CMB 15-228), and the National Natural Science Foundation of China (81571130090, 91543112)

摘要: 目的:分析使用家用高效空气过滤净化器(HEPA净化器)对北京市冬季某区居民住宅室内PM2.5浓度及其各元素组分的影响。方法:于2015年11月至2016年1月间选择北京市某区20户居民住宅,分别于空气净化器开启前后3个时间阶段(0 h组:开启前24 h;24 h组:开启后24 h;48 h组:开启后24~48 h)同步收集室内外PM2.5,采用电感耦合等离子体质谱法及等离子体发射光谱法测定PM2.5样品中21种元素含量,用室内外污染物浓度比值(indoor/outdoor ratio, I/O比值)与ΔI/O比值描述PM2.5及其组分的污染水平和变化幅度,采用单因素重复测量方差分析比较净化器开启前后不同组别PM2.5及其组分的I/O比值变化,Bonferroni法进行组间比较,采用配对样本比较的Wilcoxon符号秩检验方法比较PM2.5与各元素组分的ΔI/O比值。结果:3组PM2.5的I/O比值中位数分别为1.27(P25~P75:0.50~2.68)、0.45(P25~P75:0.27~1.03)和0.36(P25~P75:0.28~2.48)。与0 h组相比,24 h组(P=0.042)和48 h组(P=0.006)的I/O比值均显著下降,但24 h组和48 h组之间差异无统计学意义;24 h组和48 h组中,Al、Fe、Ti 3种元素的ΔI/O比值与PM2.5的ΔI/O比值差异有统计学意义(P<0.05),且此3种元素I/O比值随净化器开启时间阶段变化不显著(P>0.05)。结论:家用HEPA净化器能够有效降低室内PM2.5浓度,PM2.5浓度在净化器开启一定时间后趋于稳定,空气净化器对PM2.5不同元素组分影响不同,对大部分元素效果显著。

关键词: 空气污染物, 颗粒物, 环境暴露, 元素, 空气污染, 室内, I/O比值

Abstract: Objective: To analyze the effect of domestic high-efficiency particulate air (HEPA) puri-fiers on the concentrations of indoor fine particulate matter (PM2.5) and its elementary constituents in 20 residences in a district of Beijing during winter. Methods: From November 2015 to January 2016, 20 residences in a district of Beijing were selected, where indoor and outdoor PM2.5 data were collected simultaneously in three time periods according to the operating of air purifiers (Group 0 h: 24 hours before operating; Group 24 h: 24 hours after operating; Group 48 h: 24 to 48 hours after operating). The content of 21 elements in PM2.5 samples were determined by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICPOES). Indoor/outdoor particle concentration ratio (I/O ratios) and ΔI/O ratios were used to describe the pollution levels and the variation range of PM2.5 and its 21 elementary constituents. One-way analysis of variance (ANOVA) for repeated measurement data was applied to compare the I/O ratios of PM2.5 and its elementary constituents among the different groups, and Bonferroni method was used for comparison in pairs. Wilcoxon signed rank test for paired-samples was used to compare ΔI/O ratios of 21 elementary consti-tuents with that of PM2.5. Results: The median I/O ratios of PM2.5 in the three groups were 1.27 (P25-P75: 0.50-2.68), 0.45 (P25-P75: 0.27-1.03) and 0.36 (P25-P75: 0.28-2.48), respectively. Compared with Group 0 h, the I/O ratios of PM2.5 in Group 24 h (P=0.042) and Group 48 h (P=0.006) decreased significantly. However, there was no significant difference between Group 24 h and Group 48 h. Significant differences were found comparing ΔI/O ratios of aluminium, ferrum and titanium to that of PM2.5, in both Group 24 h and Group 48 h (P<0.05). No significant change was found in the I/O ratios of these three elements among the three groups before and after air purifier operating (P>0.05). Distances from residences to traffic arteries could affect I/O ratios of some elements from trafficrelated source (P<0.05). Conclusion: Domestic HEPA air purifiers could effectively reduce indoor PM2.5 concentration, and the pollution level of PM2.5 tend to be stable after the purifier operating for a time. The purifiers had different effects on different elements, among which most showed statistical significances.

Key words: Air pollutants, Particulate matter, Environmental exposure, Elements, Air pollution, indoor, I/O ratio

中图分类号: 

  •  
[1] 阎腾龙,胥嘉钰,陈田,杨鑫,王伟伟,周淑佩,牛丕业,贾光,夏交. 亚慢性PM2.5和O3共同暴露对大鼠鼻黏膜ATP总量及ATP酶活性的影响[J]. 北京大学学报(医学版), 2024, 56(4): 687-692.
[2] 庞博,郭桐君,陈曦,郭华棋,石嘉章,陈娟,王欣梅,李耀妍,单安琪,余恒意,黄婧,汤乃军,王艳,郭新彪,李国星,吴少伟. 天津与上海35岁以上人群氮氧化物个体暴露水平及其影响因素[J]. 北京大学学报(医学版), 2024, 56(4): 700-707.
[3] 郭煌达,彭和香,王斯悦,侯天姣,李奕昕,章涵宇,王梦莹,武轶群,秦雪英,唐迅,李劲,陈大方,胡永华,吴涛. 短期大气颗粒物暴露和MTNR1B基因多态性对甘油三酯-葡萄糖指数影响的家系研究[J]. 北京大学学报(医学版), 2024, 56(3): 375-383.
[4] 姬学朝,刘珊,王万州,赵烨彤,李陆一,张文楼,沈国锋,邓芙蓉,郭新彪. 室内挥发性有机物与年轻女性夜间心率变异性关联的定组研究[J]. 北京大学学报(医学版), 2023, 55(3): 488-494.
[5] 张宏,董继元,王建军,范临夏,曲强,刘洋. 兰州市臭氧对儿童哮喘的短期影响及其季节性差异[J]. 北京大学学报(医学版), 2022, 54(2): 227-235.
[6] 白枫,何倚帆,牛亚楠,杨若娟,曹静. 超细颗粒物对大鼠离体灌注心脏功能的影响[J]. 北京大学学报(医学版), 2021, 53(2): 240-245.
[7] 孙颖,靳蕾. 中国北方3县妊娠妇女血液锰浓度及其影响因素[J]. 北京大学学报(医学版), 2018, 50(3): 463-468.
[8] 范爱琴,冯金秋,刘伟,张敏佳,刘坦,周雅琳,许雅君. 槲皮素拮抗大气细颗粒物PM2.5对大鼠胚胎毒性的体外研究[J]. 北京大学学报(医学版), 2017, 49(3): 388-393.
[9] 张怡,宋晓明,赵茜,王童,李丽娟,陈婕,徐洪兵,刘贝贝,孙晓燕,贺蓓,黄薇. 大气颗粒物及多环芳烃暴露与慢性阻塞性肺疾病患者全身性氧化应激水平[J]. 北京大学学报(医学版), 2017, 49(3): 394-402.
[10] 曹宇,刘徽,张俊,黄克武,赵厚宇,杨羽,詹思延. 北京市颗粒物污染对慢性阻塞性肺疾病急性加重住院的影响[J]. 北京大学学报(医学版), 2017, 49(3): 403-408.
[11] 吴筱音,李国星,王旭英,梁凤超,潘小川. 北京市大气污染与呼吸系统疾病死亡的相关性——基于卫星遥感数据的时空分析[J]. 北京大学学报(医学版), 2017, 49(3): 409-417.
[12] 单娇,李宏宇,刘国峰,杨玄,董伟,简伟研,邓芙蓉,郭新彪. 大气污染对中老年高血压和心脑血管疾病患者卫生服务需求的影响:基于 CHARLS数据的分析[J]. 北京大学学报(医学版), 2016, 48(3): 460-464.
[13] 潘小川. 关注中国大气灰霾(PM2.5)对人群健康影响的新常态[J]. 北京大学学报(医学版), 2015, 47(3): 377-379.
[14] 朱一丹, 魏建荣, 黄露, 王绍华, 田寒梅, 郭新彪. 不同大气污染程度地区学龄儿童呼吸系统疾病及症状发生的比较[J]. 北京大学学报(医学版), 2015, 47(3): 395-399.
[15] 黄婧, 郭斌, 郭新彪. 交通噪声对人群健康影响的研究进展[J]. 北京大学学报(医学版), 2015, 47(3): 555-558.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!