北京大学学报(医学版) ›› 2019, Vol. 51 ›› Issue (2): 335-339. doi: 10.19723/j.issn.1671-167X.2019.02.025

• 论著 • 上一篇    下一篇

计算机辅助设计与制作一体化聚醚醚酮可摘局部义齿不同形态组件的适合性评价

李欣欣1,柳玉树1,孙玉春2,陈虎2,叶红强1,(),周永胜1,()   

  1. 1. 北京大学口腔医学院·口腔医院, 修复科 国家口腔疾病临床医学研究中心 口腔数字化医疗技术和材料国家工程实验室 口腔数字医学北京市重点实验室, 北京 100081;
    2. 北京大学口腔医学院·口腔医院口腔医学数字化研究中心, 北京 100081;
  • 出版日期:2019-04-18 发布日期:2019-04-26
  • 通讯作者: 叶红强,周永胜 E-mail:yhqfy@163.com;zhouysh72@163.com
  • 基金资助:
    首都卫生发展科研专项项目(首发2018?2?4101);科技北京百名领军人才培养工程(Z171100001117169);北京大学口腔医院青年科研基金(PKUSS20170204)

Evaluation of one-piece polyetheretherketone removable partial denture fabricated by computer-aided design and computer-aided manufacturing

Xin-xin LI1,Yu-shu LIU1,Yu-chun SUN2,Hu CHEN2,Hong-qiang YE1,(),Yong-sheng ZHOU1,()   

  1. 1. Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology,Beijing 100081, China;
    2. Center for Digital Dentistry,Peking University School and Hospital of Stomatology,Beijing 100081, China
  • Online:2019-04-18 Published:2019-04-26
  • Contact: Hong-qiang YE,Yong-sheng ZHOU E-mail:yhqfy@163.com;zhouysh72@163.com
  • Supported by:
    the Capital’s Funds for Health Improvement and Research (CFH 2018?2?4101);the Project for Culturing Leading Talents in Scientific and Technological Innovation of Beijing(Z171100001117169);PKU School of Stomatology for Talented Young Investigators(PKUSS20170204)

摘要:

目的: 评价用聚醚醚酮(polyetheretherketone,PEEK)制作可摘局部义齿不同形态组件的适合性。方法: 选取已进行基牙预备的下颌牙列缺损超硬石膏标准模型进行三维扫描,获得牙列缺损数字模型,联合牙科计算机辅助设计软件与逆向工程软件分别设计13个完整的可摘局部义齿,用计算机辅助制作技术制作PEEK一体化可摘局部义齿,在超硬石膏模型上试戴。用硅橡胶印模材复制义齿各组件与模型之间的间隙,采用三维偏差分析法测量牙合支托、基托和大连接体处的间隙大小,通过单因素方差分析、配对t检验分别比较各组件之间以及各组件内部的间隙差异是否有统计学意义。结果: PEEK一体化可摘局部义齿在超硬石膏模型上就位良好。单因素方差分析表明牙合支托、基托和大连接体处间隙的差异有统计学意义(P<0.01)。牙合支托处平均间隙[(84.3±23.6) μm]大于基托[(32.5±27.8) μm]和大连接体处[(49.9±47.0) μm] (P<0.01),但均满足临床需求;基托与大连接体处间隙差异无统计学意义(P>0.05)。游离端与非游离端基托处平均间隙为(25.1±55.3) μm和(41.5±17.7) μm,两者差异无统计学意义(P>0.05)。远离缺牙间隙牙合支托与靠近缺牙间隙牙合支托的平均间隙为(80.8±42.1) μm和(86.1±29.8) μm,两者差异无统计学意义(P>0.05)。结论: 数字化设计的全组件可摘局部义齿可用PEEK切削为一体化可摘局部义齿,该义齿不同形态组件均有良好的适合性,有良好的应用前景。

关键词: 计算机辅助设计, 计算机辅助制作, 聚醚醚酮, 可摘局部义齿

Abstract:

Objective: To explore a novel method for fabricating removable partial dentures (RPDs) using polyetheretherketone (PEEK) by computer-aided design and computer-aided manufacturing (CAD/CAM) technologies and to evaluate their fits for different assemblies in vitro.Methods: A standard stone cast of mandibular partial edentulous jaw was scanned using a lab scanner. Based on the digital cast, thirteen complete RPDs were designed combing dental CAD software and reverse engineering software, and then fabricated using PEEK by milling machine. Fits of assemblies were evaluated quantitatively by measuring the spaces between RPDs and casts. The gaps between RPDs and stone casts in different assemblies were duplicated using light-body silicone impression material and then measured using three-dimensional (3D) digital analysis methods in virtue of a dedicated software. Statistically, one-way analysis of variance (ANOVA) was used to compare the difference of gaps among assemblies in different shapes such as occlusal rest, denture base, and major connector. Paired-samples t test was used to compare the gaps difference for the similar shape assemblies in different areas.Results: One-piece PEEK RPDs were successfully designed and fabricated by CAD/CAM, and all the RPDs were well-seated on stone casts. The gaps between occlusal rests and casts [(84.3±23.6) μm] were significantly larger than those of denture bases [(32.5±27.8) μm] and major connectors [(49.9±47.0) μm], which meant that the fits of denture bases and major connectors were better than that of occlusal rests. However, the fits of all assemblies could be accepted clinically. For the similar shape assemblies in different areas, there were no significantly differences for gaps between distal extension denture bases [(25.1±55.3) μm] and non-extensive denture bases [(41.5±17.7) μm]. The gaps of occlusal rests adjacent and nonadjacent to the edentulous space were (86.1±29.8) μm and (80.8±42.1) μm respectively and there were no significantly difference between them either. These results implied that different locations had no apparent effect on the fits of assemblies.Conclusion: With the computer-aided design and computer-aided manufacturing technology, PEEK can be used to fabricate one-piece removable partial dentures. And all assemblies of the one-piece PEEK RPDs showed satisfying fits in vitro, indicating a promising clinical application in the future.

Key words: Computer-aided design, Computer-aided manufacturing, Polyetheretherketone, Removable prosthodontics

中图分类号: 

  • R783.3

图1

数字化下颌牙列缺损标准模型"

图2

计算机辅助设计可摘局部义齿各个组件"

图3

完整的可摘局部义齿三维数据(A)与PEEK一体化可摘局部义齿(B)"

图4

不同形态组件的三维偏差分析"

[1] Williams RJ, Bibb R, Rafik T . A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying[J]. J Prosthet Dent, 2004,91(1):85-88.
doi: 10.1016/j.prosdent.2003.10.002
[2] Han J, Wang Y, Lu P . A preliminary report of designing removable partial denture frameworks using a specifically developed software package[J]. Int J Prosthodont, 2010,23(4):370-375.
[3] Panayotov IV, Orti V, Cuisinier F , et al. Polyetheretherketone (peek) for medical applications[J]. J Mater Sci Mater Med, 2016,27(7):118.
[4] Najeeb S, Zafar MS, Khurshid Z , et al. Applications of polyetheretherketone (peek) in oral implantology and prosthodontics[J]. J Prosthodont Res, 2016,60(1):12-19.
doi: 10.1016/j.jpor.2015.10.001
[5] Costa-Palau S, Torrents-Nicolas J, Brufau-de Barbera M , et al. Use of polyetheretherketone in the fabrication of a maxillary obturator prosjournal: a clinical report[J]. J Prosthet Dent, 2013,112(3):680-682.
[6] Zoidis P, Papathanasiou I, Polyzois G . The use of a modified polyetheretherketone (peek) as an alternative framework material for removable dental prostheses. A clinical report[J]. J Pros-thodont, 2015,25(7):580-584.
[7] Tannous F, Steiner M, Shahin R , et al. Retentive forces and fatigue resistance of thermoplastic resin clasps[J]. Dent Mater, 2012,28(3):273-278.
doi: 10.1016/j.dental.2011.10.016
[8] Frank RP, Brudvik JS, Leroux B , et al. Relationship between the standards of removable partial denture construction, clinical acceptability, and patient satisfaction[J]. J Prosthet Dent, 2000,83(5):521-527.
doi: 10.1016/S0022-3913(00)70008-4
[9] Stern MA, Brudvik JS, Frank RP . Clinical evaluation of removable partial denture rest seat adaptation[J]. J Prosthet Dent, 1985,53(5):658-662.
doi: 10.1016/0022-3913(85)90015-0
[10] Dunham D, Brudvik JS, Morris WJ , et al. A clinical investigation of the fit of removable partial dental prosjournal clasp assemblies[J]. J Prosthet Dent, 2006,95(4):323-326.
doi: 10.1016/j.prosdent.2006.02.001
[11] Ye H, Ning J, Li M , et al. Preliminary clinical application of removable partial denture frameworks fabricated using computer-aided design and rapid prototyping techniques[J]. Int J Pros-thodont, 2017,30(4):348-353.
doi: 10.11607/ijp.5270
[12] Luthardt RG, Bornemann G, Lemelson S , et al. An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing[J]. Int J Prosthodont, 2004,17(6):680-685.
[13] Rantanen T, Eerikäinen E . Accuracy of the palatal plate of removable partial dentures, and influence of laboratory[J]. Dent Mater, 1986,2(1):28-31.
doi: 10.1016/S0109-5641(86)80066-5
[1] 李怡,王丽瑜,刘晓强,周倜,吕季喆,谭建国. 不同材料及厚度椅旁CAD/CAM瓷贴面的边缘特征[J]. 北京大学学报(医学版), 2022, 54(1): 140-145.
[2] 邱淑婷,朱玉佳,王时敏,王飞龙,叶红强,赵一姣,刘云松,王勇,周永胜. 姿势微笑位口唇对称参考平面的数字化构建及初步应用验证[J]. 北京大学学报(医学版), 2022, 54(1): 193-199.
[3] 王立新,许晓,倪耀丰,孙海涛,余日月,魏世成. 载药脂质体修饰的聚醚醚酮植入物的抑菌和骨整合性能[J]. 北京大学学报(医学版), 2021, 53(4): 758-763.
[4] 尹祯敏,王子轩,陈俊锴,孙玉春,刘云松,叶红强,周永胜. 可摘局部义齿适合性方法的评价[J]. 北京大学学报(医学版), 2021, 53(2): 406-412.
[5] 岳兆国,张海东,杨静文,侯建霞. 数字化评估CAD/CAM个性化基台与成品基台影响粘接剂残留的体外研究[J]. 北京大学学报(医学版), 2021, 53(1): 69-75.
[6] 徐啸翔,曹烨,赵一姣,贾璐,谢秋菲. 数字化个齿托盘制取下颌全牙列全冠预备体印模的体外评价[J]. 北京大学学报(医学版), 2021, 53(1): 54-61.
[7] 李峥,柳玉树,王时敏,张瑞,贾璐,叶红强,胡文杰,赵文艳,刘云松,周永胜. 数字化方法复制暂时修复体牙合面形态在重度磨耗病例中的应用[J]. 北京大学学报(医学版), 2021, 53(1): 62-68.
[8] 房硕博,杨广聚,康艳凤,孙玉春,谢秋菲. 数字化辅助确定再定位牙合垫颌位方法的探索和精度评价[J]. 北京大学学报(医学版), 2021, 53(1): 76-82.
[9] 罗佳,张宇,崔宏燕,祝宁,沈惠丹,邸萍,林野. 锥度固位结合数字化技术在后牙连续多牙种植即刻修复中的应用[J]. 北京大学学报(医学版), 2020, 52(5): 964-970.
[10] 魏菱,邹东,陈虎,潘韶霞,孙玉春,周永胜. 一种数字化全口义齿的临床疗效评价[J]. 北京大学学报(医学版), 2020, 52(4): 762-770.
[11] 孙玉春,王勇,邓珂慧,陈虎,李伟伟,赵一姣,潘韶霞,叶红强,周永胜. 功能易适数字化全口义齿的自主创新研发[J]. 北京大学学报(医学版), 2020, 52(2): 390-394.
[12] 游浪,邓珂慧,李伟伟,赵一姣,孙玉春,周永胜. 无牙颌患者鼻唇角变化侧面观的视觉敏感阈值[J]. 北京大学学报(医学版), 2020, 52(1): 107-112.
[13] 陈硕,贺洋,安金刚,张益. 计算机辅助设计虚拟颌位在儿童颞下颌关节强直合并颌骨畸形同期矫治中的应用[J]. 北京大学学报(医学版), 2019, 51(5): 954-958.
[14] 王冠博,叶红强,陈虎,王勇,孙玉春,周永胜. 无牙颌印模用个别托盘椅旁计算机辅助设计和三维打印系统建立与临床初步评价[J]. 北京大学学报(医学版), 2019, 51(2): 349-355.
[15] 王睿捷,刘敏,宋丹阳,杨随,王乔,王磊,冯海兰. 不同加工方法及材料制作部分贴面的边缘形貌分析[J]. 北京大学学报(医学版), 2019, 51(1): 93-99.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 张三. 中文标题测试[J]. 北京大学学报(医学版), 2010, 42(1): 1 -10 .
[2] 赵磊, 王天龙 . 右心室舒张末期容量监测用于肝移植术中容量管理的临床研究[J]. 北京大学学报(医学版), 2009, 41(2): 188 -191 .
[3] 万有, , 韩济生, John E. Pintar. 孤啡肽基因敲除小鼠电针镇痛作用增强[J]. 北京大学学报(医学版), 2009, 41(3): 376 -379 .
[4] 张燕, 韩志慧, 钟延丰, 王盛兰, 李玲玲, 郑丹枫. 骨骼肌活组织检查病理诊断技术的改进及应用[J]. 北京大学学报(医学版), 2009, 41(4): 459 -462 .
[5] 林红, 王玉凤, 吴野平. 学校生活技能教育对小学三年级学生行为问题影响的对照研究[J]. 北京大学学报(医学版), 2007, 39(3): 319 -322 .
[6] 丰雷, 程嘉, 王玉凤. 注意缺陷多动障碍儿童的运动协调功能[J]. 北京大学学报(医学版), 2007, 39(3): 333 -336 .
[7] 李岳玲, 钱秋瑾, 王玉凤. 儿童注意缺陷多动障碍成人期预后及其预测因素[J]. 北京大学学报(医学版), 2007, 39(3): 337 -340 .
[8] . 书讯[J]. 北京大学学报(医学版), 2007, 39(3): 225 -328 .
[9] 牟向东, 王广发, 刁小莉, 阙呈立. 肺黏膜相关淋巴组织型边缘区B细胞淋巴瘤一例[J]. 北京大学学报(医学版), 2007, 39(4): 346 -350 .
[10] 韩金涛, 赵军, 栾景源, 张龙. 多发结核性腹主动脉瘤一例[J]. 北京大学学报(医学版), 2007, 39(4): 361 -364 .