北京大学学报(医学版) ›› 2017, Vol. 49 ›› Issue (3): 506-511. doi: 10.3969/j.issn.1671-167X.2017.03.022

• 论著 • 上一篇    下一篇

3D打印非共面模板辅助CT引导125Ⅰ粒子植入治疗锁骨上复发转移癌的剂量学研究

郭福新,姜玉良,吉喆,彭冉,孙海涛,王俊杰△   

  1. (北京大学第三医院肿瘤放疗科, 北京100191)
  • 出版日期:2017-06-18 发布日期:2017-06-18
  • 通讯作者: 王俊杰 E-mail:junjiewang_edu@sina.cn
  • 基金资助:
     首都临床特色应用研究与成果推广科研项目(Z151100004015171)资助

3D printed template-assisted and computed tomography image-guided 125-iodine seed implantation for supraclavicular metastatic tumor: a dosimetric study

GUO Fu-xin, JIANG Yu-liang, JI Zhe, PENG Ran, SUN Hai-tao, WANG Jun-jie△   

  1. (Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China)
  • Online:2017-06-18 Published:2017-06-18
  • Contact: WANG Jun-jie E-mail:junjiewang_edu@sina.cn
  • Supported by:
    Supported by the Capital Foundation for Clinical Charac-teristics and Application Research (Z151100004015171)

摘要: 目的:对比3D打印个体化非共面模板辅助CT引导125I粒子植入治疗锁骨上复发转移癌的术前计划与术后实际验证剂量,评价3D打印个体化非共面模板的剂量准确性。方法:研究纳入2016年1—9月于北京大学第三医院肿瘤放疗科行3D打印个体化非共面模板辅助CT引导125I粒子植入治疗锁骨上复发转移癌的患者14例(15个病灶),男性8例,女性6例,年龄46~79岁(平均年龄59.9岁),Karnofsky评分(KPS,百分法)60~90(中位数80)。患者既往未接受过放射治疗者1例,曾接受放射治疗但剂量不详者1例,其余12例曾接受放射治疗,中位数60 Gy (20~70 Gy)。所有患者术前均行增强CT扫描,术前计划设计,3D打印模板制作,穿刺及125I粒子植入,处方剂量110~150 Gy。对比患者术前、术后剂量学参数,包括90%靶体积的最小吸收剂量(D90)、100%处方剂量覆盖的体积占靶体积的百分比(V100)、150%处方剂量覆盖的体积占靶体积的百分比(V150)、200%处方剂量覆盖的体积占靶体积的百分比(V200)、匹配周缘剂量(matched peripheral dose, mPD)、适形指数(conformal index,CI)、靶区外体积指数(external index,EI)。利用配对t检验对术后实际剂量参数结果与术前计划所对应的参数进行比较,通过BlandAltman法分析术前、术后剂量参数的一致性。结果:术前和术后D90、V100、V150、V200、mPD、CI等差异均无统计学意义(P>0.05),EI差异有统计学意义(P<0.05)。经BlandAltman法分析,D90、V100、V150、V200、mPD一致性欠佳,CI、EI一致性较好。结论:3D打印个体化非共面模板辅助CT引导125I粒子植入治疗锁骨上复发转移癌方法剂量精准,可达到术前剂量设计要求。

关键词: 3D打印, 近距离放射疗法, 碘放射性同位素, 放射治疗剂量, 肿瘤转移

Abstract: Objective: To compare the dosimetric data between the preoperative plans and postoperative verification in personalized 3D printed template-assisted and computed tomography (CT) image-guided 125-iodine seed implantation for supraclavicular metastatic tumor, and to evaluate the accuracy and feasibility at the dosimetry level. Methods: A total of 14 patients with supraclavicular metastatic tumor (including 15 lesions) who received 3D printed template assisted and CT image-guided 125-iodine seed implantation in Department of Radiation Oncology of Peking University Third Hospital from January to September 2016 were enrolled. There were 8 males and 6 females, aged from 46 to 79 years (mean age: 59.9 years). The Karnofsky performance score (KPS) was from 60 to 90 (median of 80). There were one patient who had not received radiotherapy before, and one patient had received radiotherapy, but the dose was unknown. The remaining 12 patients had received radiotherapy, with the median of 60 Gy (20-70 Gy), and one of them with the dose unknown. All the patients underwent preoperative enhanced CT scan, preoperative planning design, 3D printing template, puncture and particle implantation, the prescription dose from 110 Gy to 150 Gy. Comparisons of the dosimetric parameters between the postoperative verification and preoperative plans were made by paired t-test. The dose parameters inclu-ded D90, V100, V150, V200, matched peripheral dose (mPD), conformal index (CI), and external index (EI). The agreement was evaluated between the preoperative planning and postoperative actual dose parameters using BlandAltman analysis. BlandAltman plot showed the difference against the average of preoperative planning and postoperative actual dose parameters with limits of agreement (LoA) (broken lines). Results: The difference of all the data between pre-and postoperation, included D90, V100, V150, V200, mPD, and CI, which was not statistically significant (P>0.05). EI was statistically significant (P<0.05). There was poor consistency of D90, V100, V150, V200, and mPD, but better consistency of CI and EI. Conclusion: Personalized 3D printed template-assisted and CT image-guided 125-iodine seed implantation for supraclavicular metastatic tumor is accurate and feasible.

Key words: Three-dimensional printing, Brachytherapy, Iodine radioisotopes, Radiotherapy dosage, Neoplasm metastasis

中图分类号: 

  • R730.55
[1] 展新新,曹露露,项东,汤皓,夏丹丹,林红. 成型方向对3D打印口腔义齿基托树脂材料物理性能及力学性能的影响[J]. 北京大学学报(医学版), 2024, 56(2): 345-351.
[2] 胡攀攀,李彦,刘啸,唐彦超,李梓赫,刘忠军. 自稳式人工椎体在颈椎前路手术中的应用[J]. 北京大学学报(医学版), 2024, 56(1): 161-166.
[3] 周华,王仁吉,刘忠军,刘晓光,吴奉梁,党礌,韦峰. 3D打印人工椎体在颈椎脊索瘤全脊椎切除术中的应用[J]. 北京大学学报(医学版), 2023, 55(1): 144-148.
[4] 开地尔娅·阿不都热合曼,张荣赓,钱浩楠,邹振洋,丹尼娅·叶斯涛,范田园. 个性化剂量熔融沉积成型3D打印茶碱片剂的制备和体外评价[J]. 北京大学学报(医学版), 2022, 54(6): 1202-1207.
[5] 王跃,张爽,张虹,梁丽,徐玲,程元甲,段学宁,刘荫华,李挺. 激素受体阳性/人表皮生长因子受体2阴性乳腺癌临床病理特征及预后[J]. 北京大学学报(医学版), 2022, 54(5): 853-862.
[6] 孙玉春,郭雨晴,陈虎,邓珂慧,李伟伟. 口腔精准仿生修复技术的自主创新研发与转化[J]. 北京大学学报(医学版), 2022, 54(1): 7-12.
[7] 李潇,苏家增,张严妍,张丽琪,张亚琼,柳登高,俞光岩. 131I相关唾液腺炎的炎症分级及内镜治疗[J]. 北京大学学报(医学版), 2020, 52(3): 586-590.
[8] 张晔,张妮,刘晓筱,周传香. 唾液腺腺样囊性癌淋巴结转移相关的临床病理分析[J]. 北京大学学报(医学版), 2020, 52(1): 30-34.
[9] 张旭初,张建华,王荣福,范岩,付占立,闫平,赵光宇,白艳霞. 18F-FDG PET/CT联合多种肿瘤标志物在结直肠中分化腺癌术后复发及转移中的应用价值[J]. 北京大学学报(医学版), 2019, 51(6): 1071-1077.
[10] 李聪,刘树铭,郑磊,黄明伟,石妍,吕晓鸣,张建国,张杰. 手术联合 125I粒子治疗口腔颌面部腺样囊性癌的疗效与相关预后因素分析[J]. 北京大学学报(医学版), 2019, 51(1): 49-52.
[11] 黄子雄,杜依青,张晓鹏,刘士军,徐涛. 肾细胞癌骨转移的临床与病理分析[J]. 北京大学学报(医学版), 2018, 50(5): 811-815.
[12] 黄子雄,张晓鹏,董森,刘士军,杨荣利,周宇石,马伟国. 肾黏液性小管和梭形细胞癌合并骨转移1例及文献回顾[J]. 北京大学学报(医学版), 2018, 50(4): 732-735.
[13] 叶克强,黄明伟,李君利,唐劲天,张建国. 125I放射性粒子在骨介质中剂量分布的蒙特卡罗模拟[J]. 北京大学学报(医学版), 2018, 50(1): 131-135.
[14] 赵轶国,杨晓东,张雁凯,宁宁,邢兆东,叶颖江. 美克尔憩室癌变及肝多发转移并消化道出血1例[J]. 北京大学学报(医学版), 2017, 49(6): 1095-1097.
[15] 张达,王林川,周彦恒,刘晓默,李晶. 3D打印间接粘接托槽精度[J]. 北京大学学报(医学版), 2017, 49(4): 704-708.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!